Records from 2016 to 2026. Most recent: inspection, 30 March 2026.
Inspection history · 7
30 March 2026
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8333916
21 April 2023
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7672926
1 March 2023
Deficiency Check · PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7641031
24 February 2023
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7641329
26 January 2021
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7125039
14 August 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6224918
2 March 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam · MARPOL Annex VI Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5825116
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 30 March 2026
Resolved
Electrical installations shall be such that: Electrical services essential for safety will be ensured under various emergency conditions. PSCO identified break unlabeled supplying power to unknown source on emergency 44V panel. Additionally, posted emergency power supply distribution sheet was not consistent with labeled breakers.
74 SOLAS (24) II-1 40.1.2 60ac
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 March 2026
Resolution: Received BV Class report stating a breaker on the emergency panel was connected to BWTS, Class made ship disconnect breaker fixing the issue. No effect to BWTS.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 30 March 2026
Resolved
Maintenance testing and inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO observed block foam distributer above boiler, ships maintenance plan does not address visual inspection of distributors.
74 SOLAS (09) II-2/14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 August 2026
Resolution: Vessel has implemented monthly checks of the firefighting system and it's components into it's PMS. Logs of the checks were observed during the exam. Vessel will provide class report.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 March 2026
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed discharge valve on emergency fire pump closed and no prime on system.
74 SOLAS (09) II-2 14.2.1.2
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 30 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 1 March 2023
Resolved
Maintenance, testing and inspections of lifesaving appliances shall be carried out in a manner having due regard for ensuring reliability of such appliances. Rescue boat engine propeller slow to engage and engine repeatedly stalled with increased throttle.
74SOLAS(14) III/20.3.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2023
Resolution: Vessel crew adjusted carburetor and engine is running as intended.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 1 March 2023
Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. Thermal heat gun used to test heat detectors inoperable.
74SOLAS(14) II-2/14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 21 April 2023
Resolution: Recieved report attesting to proper receipt of thermal heat gun.