PORTAITISSA is a 2011 freight ship. The Coast Guard has recorded 13 inspections since 2017, most recently in July 2022, along with 5 deficiencies and 4 operational controls.
Records from 2017 to 2022. Most recent: inspection, 26 July 2022.
This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it24168 - Convention (Subpart B), Gross Ton 12138 - Convention (Subpart B), Net Ton 24168 - Regulatory (Subpart C or D), Gross Ton 12138 - Regulatory (Subpart C or D), Net Ton 46912 - Displacement, Metric Ton 37148 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 13
26 July 2022PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7509972
19 July 2022Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7511111
13 July 2020Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7118241
28 May 2020Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6962514
23 August 2018Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6521189
2 August 2018Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6493124
31 July 2018Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6496775
12 January 2018Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6337070
12 January 2018COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6337198
7 January 2018Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6333793
9 July 2017Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6202579
27 June 2017Administrative Inspection · Deficiency Check
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 2 August 2018Resolved
07126-Oil Accumilation in Engine Room The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requiremnts shall be met: means shall be provided ro control leaks of flammable liquids, PSCO observe fuel oil leak on Generator #1 coming from fuel filter at a rate of 100 drops per minute. 74 SOLAS 2014 (cons)ii-1/4.1.1 action taken. 10.c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 2 August 2018
Resolved 2 August 2018
Resolution: Crew retightend fuel fitting.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 2 August 2018Resolved
11113- Launching arrangements for rescue boats: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Installed limit switch on rescue boat davit was not operative during recovery testing and did not stop winch. The ship's crew repaired switch to the satisfaction of the PSCO. 74 SOLAS 2014 (cons) I/11. 10.c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 August 2018
Resolved 2 August 2018
Resolution: Crew was able to repair limit swith to satisfaction of PSCO.
Electrical › Electric Generation Source (emergency) › Generator
Issued 24 June 2017Resolved
The condition of ship and its equipment shall be maintained to ensure the ship will remain fir to proceed to sea. Radiator cap for emergency generator found wasted, will not create air tight seal. SOLAS (14) I/11(a). 17 b/c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2017
Resolution: Vessel provided pictures of new radiator cap.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 24 June 2017Resolved
The fire integrity of fire divisions shall be maintained at openings and penetrations. Multiple superstructure vent covers will not close properly do to gasket weathering. SOLAS (14) II-2/9.1.3; 15 b.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 14 July 2017
Resolved 9 July 2017
Resolution: PSC NOLA RECEIVED PROPER DOCUMENTATION FROM FLAG SATISFYING THE REQUIREMENT
NO FLAMMABLE OR COMBUSTIBLE LIQUID MAY BE STOWED IN CONTROL SPACE OR SERVICE SPACE. GASOLINE CANS FOUND IN THE EMERGENCY GENERATOR ROOM. 46 CFR 147.45(b); 10.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 24 June 2017
Resolution: Corrected on spot. Crew moved gasoline tanks to proper storage location.