MAURY USCG vessel records
← All vessels

VANTAGE DREAM

VANTAGE DREAM is a freight ship. The Coast Guard has recorded 5 inspections since 2017, most recently in September 2022, along with 3 deficiencies.

Records from 2017 to 2022. Most recent: inspection, 9 September 2022.

Built
Not recorded
Last inspected
9 September 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9616606
1161816
Flag
LIBERIA
Maury page id
psix-1161816

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 3 calendar years (2017–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it18481 - Convention (Subpart B), Gross Ton
10335 - Convention (Subpart B), Net Ton
36868 - Displacement, Metric Ton
29083 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 5

9 September 2022 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7554986
1 September 2022 PSC B · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7541614
27 July 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6492135
13 July 2018 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6477998
29 June 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6180627

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 27 July 2018 Resolved
0750 - Fire Prevention - Where "A" class divisions are prenetrated, such penetrations shall be tested in accordance with the Fire Test Procedures Code. Found wires installed through "A" class divisions adjacent to duct & cable spaces on A, B and C decks in accommodations. No evidence could be provided for approval of modifications of "A" class divisions. -74 SOLAS (14 Cons.)II-2/9.3.1
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 September 2022
Resolution: Penetrations on A, B, and C decks near accomodation spaces have been filled in. Deficiency Cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 July 2018 Resolved
0660 - Lifejackets - All life-saving appliances prescribed in this part shall: be clearly marked with approval information, including the Administration which approved it and any opertional restrictions. Life-jackets were not clearly marked with the approving Administration. -74 SOLAS (14 Cons.) III/34, LSA 1.2.2.9
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 September 2022
Resolution: Vessel purchased all new lifejackets, showed proper certification and satisfactory examination of lifejackets.
Documentation › Certificates/Documents › IOPP Certificate
Issued 29 June 2017 Resolved
0150-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. PSCO noted the incinerator has been INOP since August 2016. MARPOL I/6.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 June 2017
Resolution: PSCO verified proper repair of the incinerator.

Ownership record