Records from 2011 to 2024. Most recent: inspection, 6 September 2024.
Inspection history · 21
6 September 2024
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7997850
22 May 2024
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7916291
29 April 2024
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7902370
16 February 2021
PSC B · COC-CHEM & TVE Renew
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7135714
3 March 2019
Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6630532
12 May 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6412785
8 May 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6409243
10 April 2018
COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6384550
16 December 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6325279
5 December 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6318727
2 December 2017
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6599774
16 March 2017
COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6105332
20 February 2017
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6091408
28 March 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5841643
26 March 2016
COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5840746
25 March 2016
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5955013
13 October 2015
ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5741175
8 May 2014
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4853661
8 May 2014
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4853865
10 December 2011
ISPS II Exam · COC-CHEM Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4200428
9 December 2011
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4200824
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 29 April 2024
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed uninsulated penetration in “A-0” boundary leading from passageway into cable and duct trunk on “B” and “C” deck.
74SOLAS(20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2024
Resolved 13 May 2024
Resolution: Recieved call report attesting to boundary penetrations.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 29 April 2024
Resolved
Controlled tank venting systems fitted to tanks to be used for cargoes having a flashpoint not exceeding 60 degrees Celsius (closed-cup test) shall be provided with devices to prevent the passage of flame into the cargo tanks.
PSCO observed #6S and #1S flame screens with 1/4 inch gap found.
74SOLAS(20) VII/10.1\
IBC 8.3.6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2024
Resolved 29 April 2024
Resolution: Ships crew replaced the gasket around the flame screen to close the gap.
09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 29 April 2024
Resolved
: The materials of construction and the dimensions of gas sampling lines shall be such as to prevent restriction.
PSCO observed 02 deck valves closed partially causing flow fault alarms for #6 port wing ballast tank and forward cleaning tank.
74SOLAS(09)II-2/5.7.2.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2024
Resolved 29 April 2024
Resolution: Ships crew fully opened 02 deck valves.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 April 2024
Resolved
: The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed multiple pipe patches on steam line. These were noted on most recent inspection report in accordance with SMS but not reported to company.
74SOLAS(20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 May 2024
Resolved 6 September 2024
Resolution: Received and accepted class report attesting to rectification of deficiency.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 April 2024
Resolved
- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board.
PSCO observed multiple piping and safe access to bow support members with severe wastage jeopardizing crew safety. These were noted on most recent inspection report in accordance with SMS but not reported to company.
74SOLAS(20)I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 May 2024
Resolved 6 September 2024
Resolution: Received and accepted class report attesting to rectification of deficiency.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2024
Resolved
- Electrical installation shall be such as to minimize the risk of fire and explosion from flammable products.
PSCO observed multiple electrical conduit pipes in cargo deck area severely corroded and wrapped with duct tape not in compliance with hazardous location standards. These were not reported in most recent inspection in accordance with ships SMS.
74SOLAS(20)VII/10.1
IBC 10.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 May 2024
Resolved 6 September 2024
Resolution: Received and accepted class report attesting to rectification of deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 29 April 2024
Resolved
Each vessel vapor connection flange face must have a permanent stud projecting outward that had a 12.7 millimeter (0.5 inch) diameter and is at least 25.4 millimeters (1 inch) long. It must be located at the top of the flange face, midway between bolt holes, and in like with the bolthole pattern.
PSCO observed starboard forward vapor flange missing vapor stud.
46CFR39.2001(j)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 6 May 2024
Resolved 13 May 2024
Resolution: Recieved class report attesting to repairs to vapor stud.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 29 April 2024
Resolved
The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the provisions of the relevant rules and regulations established by the company. In meeting these requirements the company should ensure that: any non-conformity is reported with its possible cause if known the technical and or operational nature of the deficiencies noted provide objective evidence of a serious failure of implementation of the ISM code. An internal audit report satisfactory to the OCMI must be submitted prior to the clearance of this deficiency.
74SOLAS(20)IX/3.1
ISM CODE 10.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2024
Resolved 6 September 2024
Resolution: Received and accepted class report attesting to rectification of deficiency.
Documentation › Manuals/Policy Documentation › Procedures and Arrangements Manual (NLS)
Issued 10 April 2018
Resolved
1911-P&A Manual: Vessel was refitted with an additional nitrogen generator system for inerting cargo tanks, but system was not amended into current P & A manual. MARPOL Annex II/14. -50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2018
Resolved 8 May 2018
Resolution: SEC HOU-GAL PSC received proper documentation from ABS satisfying the requirement.
Deck/Cargo › Inert Gas System › IGS Scrubber
Issued 16 March 2017
Resolved
1050-INERT GAS ALARM-AUTOMATIC SHUTDOWN OF INERT GAS BLOWERS SHALL BE ARRANGED ON PREDETERMINED LIMITS, LOW WATER PRESSURE TO THE IGG SCRUBBER. PRESSSURE SWITCH FOR SCRUBBER DID NOT INITIATE AUTOMATIC SHUTDOWN OF IG SYSTEM. SOLAS 74 (14) II-2/4.5.5, FSS CODE 15.2.3.1.5. 10C
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 16 March 2017
Resolution: CREW CLEANED CONTACTS OF PRESSURE SWITCH. PSCO CONDUCTED NEW TEST OF SYSTEM. ALL SHUTDOWNS WORKED AS DESIGNED.