Records from 2016 to 2025. Most recent: inspection, 16 June 2025.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 July 2024
Resolved
Fire extinguishing equipment installed on a vessel must be maintained in accordance with industry standard and a pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions. MI observed pre-engineered system without a current inspection sticker.
46 CFR 181.120(a), 46 CFR 181.420(a)(4) 60 c
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 July 2024
Resolution: Rcvd current servicing report.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 2 July 2024
Resolved
A vessel on a rivers route must carry three hand red flare distress signals and three hand orange smoke distress signals. One of the following may be substituted for any of the hand orange smoke distress signals, a hand red flare distress signal. MI observed three hand red flares and two orange smoke signal, vessel needs to carry six distress signals.
46 CFR 180.68(b)(1),
46 CFR 180.68(b)(2),
46 CFR 180.68(c)(2)
60 c
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 July 2024
Resolution: Rcvd photo of proper type and quantity.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 July 2024
Resolved
Shutoff valves must be fitted in the fuel supply lines. MI observed remote fuel shutoffs to be not fully operational.
46 CFR 182.455(b)(4) 60 c
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 July 2024
Resolution: Rcvd photo of adjusted remote fuel shutoffs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 July 2024
Resolved
All fuel tanks must be electrically bonded to a common ground. MI observed broken grounding wire on fuel tank.
46 CFR 182.440(b)(4) 60 c
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 July 2024
Resolution: Rcvd photographic evidence of corrected deficiency
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 July 2024
Resolved
A vessel not required to have a power driven fire pump must have (03) 2.5 gallon fire buckets. MI observed (03) fire buckets that were not the required 2.5 gallon.
46 CFR 181.610 60 c
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 July 2024
Resolution: Rcvd photo of proper size firebuckets.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 July 2024
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining water tight. MI observed a missing threaded watertight plug between bulkheads.
46 CFR 179.320(a) 60 c
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 July 2024
Resolution: Rcvd photo of threaded plug installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 July 2024
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining water tight. MI observed several small holes in the deck beneath the helm.
46 CFR 179.320(a) 16 c
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2024
Resolved 3 July 2024
Resolution: Rcvd photo of small holes filled and corrected.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 July 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: prevent electrical ignition of flammable vapors. MI observed a LED light installed incorrectly in the fuel tank compartment.
46 CFR 183.200(d) 16 c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2024
Resolved 3 July 2024
Resolution: Rcvd photo of unapproved light removed.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 5 June 2023
Resolved
A fixed gas fire extinguishing system aboard a vessel must be approved by the Commandant, and be custom engineered to meet the requirements of this section unless the system meets the requirements of 181.420. MI discovered several small screw holes and approximately a 10 inch by 10 inch access plate not secured, which will allow extinguishing agent to escape the space in case of a fire. Repair access to ensure vapor and watertight integrity. 46CFR 181.410(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 June 2023
Resolved 6 June 2023
Resolution: Recieved photo of newly replaced access plate and screw holes, all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 July 2022
Resolved
The area of the ventilation ducts must be sufficient to
limit the air velocity to a max of 2,000 feet/minute.
The two 4" exhaust fans have a rate of 235 cfm each
which equals an air velocity over 2900 ft/min. Either
the ducting needs to be increased to 4.65 inch diameter
or more on both sides of the fans, or the fans must have
speed adjuster controls installed near the console that
can reduce the fan speeds to 2/3 of it's max speed.
46 CFR 182.460(f)
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 September 2022
Resolution: Cleared to the satisfaction of the Marine Inspector
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2022
Resolved
Where a flexible fill pipe section is necessary, suitable flexible tubing or hose having high resistance and the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. No grounding conductor installed. Install suitable grounding wire connecting the fill spout to the fuel tank to the satisfaction of the attending marine inspector.
Fuel tank vent lines didn't have a grounding strap.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 September 2022
Resolution: Cleared to the satisfaction of the Marine Inspector
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2022
Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable
Fuel tank vent lines didn't have double hose clamps.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 September 2022
Resolution: Cleared to the satisfaction of the Marine Inspector
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2022
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant.
Spec sheets need to be provided for fuel tank vent lines to verify that they meet the SAE J-1942 standards.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 September 2022
Resolution: Cleared to the satisfaction of the Marine Inspector
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2022
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent.
Closures need to be installed at the ends of the gasoline tank compartment powered exhaust ventilation ducts.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 September 2022
Resolution: Cleared to the satisfaction of the Marine Inspector
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2022
Resolved
For an enclosed space: (i) At least two natural ventilation supply ducts located at one end of the space and that extend to the lowest part of the space or to the bilge on each side of the space. (ii) A mechanical exhaust system consisting of at least two ventilation
exhaust ducts located at the end of the space opposite
from where the supply ducts are fitted, which extend to
the lowest part of the bilge of the space on each side
of the space, and which are led to one or more powered
exhaust blowers.
Ducting needs to be installed from the two natural ventilation supply vents and run to the lowest parts of
the bilge on each side of the space.
Ducting needs to be installed on the suction side of the powered exhaust blowers and run to the lowest parts of the bilge on each side of the space.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 September 2022
Resolution: Cleared to the satisfaction of the Marine Inspector
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2022
Resolved
The area of the ventilation ducts must be sufficient to limit the air velocity to a maximum of 10 meters per second (2,000 feet per minute). A duct may be of any shape, provided that in no case will one cross sectional dimension exceed twice the other.
Need to provide the brand and model number of the ducting exhaust fans to verify their specs and that it meets the reg.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 September 2022
Resolution: Cleared to the satisfaction of the Marine Inspector
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2022
Resolved
A cable must not be spliced in a hazardous location.Bilge alarm/pump wiring splices in the gasoline fuel compartment need to be in an explosion proof junction box all wiring splices in this space must be in explosion proof junction boxes and to the satisfaction of the MI.
46 CFR 183.340(l)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2022
Resolved 9 September 2022
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2022
Resolved
Electrical equipment in spaces containing machinery powered by, or fuel tanks for, gasoline or other fuels having a flashpoint of 43.3 °C (110 °F) or lower must be explosion-proof or ignition-protected, or be part of an intrinsically safe system. Move 120v outlet box and plugged in battery charger out of the gasoline fuel tank space and to the satisfaction of the MI.
46 CFR 183.530(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 July 2022
Resolved 9 September 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2022
Resolved
The area of the ventilation ducts must be sufficient to
limit the air velocity to a max of 2,000 ft/min. The two
1 inch diameter natural ventilation supply ducts to the
gasoline tank space were smaller than the exhaust ducts
when they should be the same size or larger.
46 CFR 182.460(f)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 September 2022
Resolution: Cleared to the satisfaction of the Marine Inspector
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 June 2022
Resolved
A supply duct must be provided at its intake opening
with a cowl or scoop having a free area not less than
twice the required duct area. When the cowl or scoop is
screened, the mouth area must be increased to compensate
for the area of the screen wire. For example, a 4.65
inch diameter round duct has an area of 16.98 square
inches and would need a 6.57 inch diameter round cowl or
larger. Also, a 4 inch diameter round duct has an area
of 12.57 square inches and would need a 5.66 inch
diameter round cowl or larger.
46 CFR 182.460(i)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 September 2022
Resolution: Cleared to the satisfaction of the Marine Inspector
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 19 July 2021
Resolved
Aft most WTB was found holed. Previously had equipment mounted using tap screws but has since been removed leaving the bulkhead holed.
Make bulkhead watertight.
Action required: 10 - Deficiency Rectified
Due 19 July 2021
Resolved 19 July 2021
Resolution: Corrected on the spot. Pin holes have been sealed watertight.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 July 2021
Resolved
Port navigation light found inop. Repair prior to operations.
Action required: 10 - Deficiency Rectified
Due 19 July 2021
Resolved 19 July 2021
Resolution: Def was corrected on the spot, by replacement of damaged electrical wire connection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 July 2021
Resolved
Four (04) type II non-commercial use life jackets found on board and being used for commerical operations. Replace those four with type I USCG approved life jackets.
Action required: 10 - Deficiency Rectified
Due 19 July 2021
Resolved 19 July 2021
Resolution: Four (04) type I life jackets, properly marked have been added to the vessel and the four non approved type have been removed. Def cleared on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 July 2021
Resolved
The life ring was missing the quick disconnect clip on life ring float light. Found float light tied to the life ring.
Action required: 10 - Deficiency Rectified
Due 19 July 2021
Resolved 19 July 2021
Resolution: Added quick disconnect clip and line to float light and properly attached to life ring.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 19 July 2021
Resolved
Aft most void space was found with a in-operational bilge alarm unit. Replace with functioning bilge alarm.
Action required: 10 - Deficiency Rectified
Due 19 July 2021
Resolved 19 July 2021
Resolution: Bilge alarm unit replaced in kind. corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 June 2019
Resolved
Fixed firefighting system past servicing date. Provide proof of servicing to satisfaction of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2019
Resolution: Provided technician report of servicing.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 10 June 2019
Resolved
Open penetration in FWD bow void allowing water ingress. Repair to satisfaction of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2019
Resolution: Provided proof of repair via picture.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 10 June 2019
Resolved
Vessel has 2 fire buckets onboard. Provide proof of required 3 buckets to satisfaction of CG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2019
Resolution: Provided proof of additional bucket via picture.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 14 June 2017
Resolved
In normal position, Fireboy alarms and green light indicating system is charged do not turn on. Operation is no different when wire is disconnected. Prove proper operation to satisfaction of attending marine inspector prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2017
Resolved 19 June 2017
Documentation › Markings/Placards › Oil Discharge Placard
Issued 14 June 2017
Resolved
Replace oil discharge placard.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 19 June 2017
Documentation › Certificates/Documents › FCC SSL
Issued 14 June 2017
Resolved
Post FCC station license and safety certificate
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 19 June 2017
Documentation › Certificates/Documents › Stability Letter
Issued 14 June 2017
Resolved
Post stability letter.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 19 June 2017
Navigation › Piloting/Steering › Deviation Table/Graph
Issued 14 June 2017
Resolved
Post compass deviation table.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 19 June 2017
Construction/Loadline › Penetrations › Gasket
Issued 14 June 2017
Resolved
Replace packing in aft compartment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 19 June 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2017
Resolved
Wrap all butt connectors with electrical tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 19 June 2017
Documentation › Logs/Records › Logbook (official)
Issued 14 June 2017
Resolved
Provide logs of safety drills and conduct M.O.B. drills in presence of Marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 19 June 2017
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 14 June 2017
Resolved
Either replace lifejackets so all are of same type or provide donning placard for each type on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 19 June 2017
Construction/Loadline › Hull › Weld
Issued 14 June 2017
Resolved
Repair crack in port forward towing extension to satisfaction of attending CG Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 19 June 2017
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 12 September 2016
Resolved
Packing was missing between the operating station and the aft compartment. Packing was missing between the aft compartment to the twin gasoline outboard engines. The aft compartment has a pre-engineered fire extinguishing system, that is designed to protect it; due to missing packing the space is not properly protected. A vessel is inspected for compliance with the standards.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2016
Resolved 21 September 2016
Resolution: Received pictures confirming space below deck now has packing both to the operating station and to the outboard engines.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 12 September 2016
Resolved
essel rep was unable to perform the system test for the pre-engineered fire extinguishing system per manufacturer's instructions. The visual indicator at the operating station indicating the device was in ready status was non-operational. The bottle for the pre- engineered system was not fully charged. All other vessels must undergo an inspection for certification as specified in §176.404.
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 September 2016
Resolved 21 September 2016
Resolution: A new CO2 bottle was placed on board and a technician verified the proper operation of the system. Received picutues confirming they system set up for proper operation.
Lifesaving › Visual Distress Signals (General) › Marking
Issued 12 September 2016
Resolved
Portable watertight containers for distress flares was not marked. Portable watertight containers for distress flares and smoke signals shall be clearly marked in legible contrasting letters“DISTRESS SIGNALS."
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 21 September 2016
Resolution: Received pictures verifying proper marking on the distress flares container.
Lifesaving › Buoyant Smoke Signals › General
Issued 12 September 2016
Resolved
Vessel was missing one orange smoke signal. A vessel on a lakes, bays, and sounds, or rivers route must carry: Three hand orange smoke distress signals approved in accordance with §160.037 in subchapter Q of this chapter. Conduct repairs to the satisfaction of the attending CG marine inspector.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 21 September 2016
Resolution: Received pictues verifying three orange smoke flares are now onboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 September 2016
Resolved
Aspirin was expired in first aid kit. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
Action required: 705 - Other - as specified
Due 17 September 2016
Resolved 21 September 2016
Resolution: Received pictures verifying purchase of new first aid kit with medication that is not expired.