← All vessels
NOMAD
Passenger (Inspected) · Passenger Ship class · Built 2010s · USCG East District (CGD-E) · Other hulls named NOMAD
NOMAD is a 2012 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2011, most recently in May 2026, along with 14 deficiencies.
Records from 2011 to 2026. Most recent: inspection, 12 May 2026.
- Built
- 2012
- Last inspected
- 12 May 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 14 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1238682
WDG3770
1162389
Flag
UNITED STATES
367529470
Maury page id
psix-1162389
Inspections, by type
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)47.0 ft × 18.0 ft × 8.0 ft
Registered tonnagegross 22 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAINE CAT · BREMEN, ME, UNITED STATES · built 2012
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portTOWNSENDS INLET, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Simplified, Gross Ton
18 - Simplified, Net Ton
18 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDM9935MMSI 367529470 · active · compulsorily equipped · granted 19 May 2022, expires 19 May 2032
WDG3770MMSI 367529470 · cancelled · compulsorily equipped · granted 3 March 2022, cancelled 3 March 2022 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
12 May 2026
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8357218
29 November 2023
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7831270
7 April 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7663150
13 April 2022
COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7430091
22 March 2021
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7166791
20 February 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6912268
11 June 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6440675
16 April 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6392583
23 May 2017
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6152697
13 June 2016
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5905770
11 April 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5851203
18 August 2014
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4958303
1 May 2012
Deficiency Check · Plan Review "T" Boat · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4299609
6 December 2011
Construction Oversight
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 4221359
Deficiency record · 14
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 11 June 2018
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines and all engines that draw intake air from within the protected space. The ventilation for the engine space was not able to be secured due to broken cable arrangement. 46 CFR 181.420(a)(3)
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 June 2018
Resolved
Each connection to a conductor or terminal must be made within an enclosure. Bilge pump wiring connections in each engine bay were not in enclosures. 46 CFR 183.340(g)
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 June 2018
Resolved
Each floating waterlight must be attached to the ring life buoy lanyard by a corrosion-resistant clip. The waterlight was tied to the ring life buoy. 46 CFR 180.70(d)(3)
Navigation › Piloting/Steering › US Coast Pilot
Issued 11 June 2018
Resolved
The vessel must have U.S. Coast Pilot or similar publication. Vessel did not have publication on board. 46 CFR 184.420(a)(2)
Fire Fighting › Fire Bucket › Stenciling
Issued 11 June 2018
Resolved
The words FIRE BUCKET must be stenciled in a contrasting color on each fire bucket. The fire buckets on board the vessel were unmarked. 46 CFR 181.610
Documentation › Logs/Records › Drug Test Records
Issued 23 May 2017
Resolved
Conduct a DAPI audit and provide proof of compliance.
Engineering › Bilge Water Management System › Piping
Issued 1 May 2012
Resolved
Replace plastic sea strainer with approved metallic type.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 May 2012
Resolved
Properly post COD
Documentation › Certificates/Documents › Stability Letter
Issued 1 May 2012
Resolved
Properly post stability letter
Operations/Management › Drills/Instruction › Fire
Issued 1 May 2012
Resolved
Provide and post fire emergency instruction procedures
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 1 May 2012
Resolved
Provide proof of proper enrollment into a drug and alcohol testing program
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 1 May 2012
Resolved
Cover engine-room penatrations with proper structural fire protection insulation.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 May 2012
Resolved
Fit lifebuoys with proper float light that meets approval series 161.010.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 May 2012
Resolved
Vessel must perform proper manoverboard drills and provide means of recovering person from the water.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.