DEVBULK SALIHA is a 2011 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in October 2025, along with 3 deficiencies — 1 with no resolution recorded — and 3 operational controls.
Records from 2016 to 2025. Most recent: inspection, 7 October 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it19999 - Convention (Subpart B), Gross Ton 10792 - Convention (Subpart B), Net Ton 39423 - Displacement, Metric Ton 31018 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 9
7 October 2025Deficiency Check · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8245522
27 February 2025Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8085651
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 October 2025Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed multiple CO2 bottles not secured which led to multiple rubber hoses to be twisted and damaged.
74SOLAS(09) II-2/14.2.1.2, 10c
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 7 October 2025
Resolution: CO2 rubber hoses corrected and bottles secured properly. Rectified on the spot.
All steering gear components and the rudder shall be of sound and reliable construction to the satisfaction of the Administration. PSCO observed a harsh vibration and an inconsistent rate of turn during the steering test.
74SOLAS(24) II-1 / 29.2.1, 60ac
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 October 2025
Resolution: Received, reviewed and accepted class report from ABS stating that the Load sequence valve was replaced on steering pump #2. Full operational testing carried out and witnessed by ABS on steering pumps #1 and #2, all found to be satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 October 2025No resolution recorded
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and fire alarm systems . PSCO observed faults on 03 fire detectors in the battery room, galley and forecastle. Vessel reported faults on E-NOA and to flag. No dispensation issued.
74SOLAS(09) II-2/14.2.1.1.2, 17ac, Changed to 40ac after receiving class report.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolution: Received, reviewed and accepted class report from ABS stating that the technician on board was unable to make permanent repairs. Short Term Cargo Ship Safety Equipment Certificate issued for 40 days, until vessel can make permanent repairs in China.