← All vessels
WL PACIFIC
WL PACIFIC is a 2011 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in February 2025, along with 2 deficiencies and 1 operational control.
Records from 2016 to 2025. Most recent: inspection, 11 February 2025.
- Built
- 2011
- Last inspected
- 11 February 2025
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 2 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded3
Years with a record
5 calendar years (2016–2025)
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it24079 - Simplified, Gross Ton
24079 - Convention (Subpart B), Gross Ton
33413 - Dead Weight, Metric Ton
43732 - Displacement, Metric Ton
10652 - Convention (Subpart B), Net Ton
24079 - Convention (Subpart B), Gross Ton
33413 - Dead Weight, Metric Ton
43732 - Displacement, Metric Ton
10652 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 10
11 February 2025
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8070242
22 June 2021
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7221264
28 July 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7018364
26 July 2020
PSC B · Damage Survey · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7014823
26 July 2020
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7024658
27 January 2020
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6896650
4 May 2017
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6138772
8 November 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6032692
7 November 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6036887
7 November 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6037097
Deficiency record · 2
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 11 February 2025
Resolved
The voyage data recorder system, including all sensors, shall be subjected to an annual performance test. A copy of the certificate of compliance isued by the testing facility, stating the date of compliance and the appliacable performance standards shall be retained onbaord the ship. PSCO observed 03 errors on VDR. Crew could not find required certificate of compliance to accompany performance test report dated 23JAN2024. Request attestation of proper operation of VDR from approve dtesting facility and RO. SOLAS (20) V/18.8
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 July 2020
Resolved
13101-
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces and other hazards. The design shall have regard to materials used in construction, the purpose for which the equipment is intended, the working conditions to which it will be subjected and the environmental conditions on board. PSCO observed cooling water leaking excessively from #4 Cylinder on Main Diesel Engine.
74SOLAS(2004) II-1/26.1
60 A/C
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.