← All vessels
KALVOE
KALVOE is a 2011 freight ship. The Coast Guard has recorded 9 inspections since 2011, most recently in March 2020, along with 16 deficiencies and 6 operational controls.
Records from 2011 to 2020. Most recent: operational control imposed, 19 March 2020.
- Built
- 2011
- Last inspected
- 19 March 2020
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9518983 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
D5BQ5
1162590
Flag
CYPRUS
—
Maury page id
psix-1162590
Inspections, by type
…with no type recorded3
Years with a record
4 calendar years (2011–2020)
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it4220 - Convention (Subpart B), Gross Ton
2456 - Convention (Subpart B), Net Ton
5646 - Dead Weight, Metric Ton
8167 - Displacement, Metric Ton
2456 - Convention (Subpart B), Net Ton
5646 - Dead Weight, Metric Ton
8167 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 9
19 March 2020
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6928664
21 February 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6913137
19 February 2020
Deficiency Check · PSC A
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6911391
18 February 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6910477
14 February 2020
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6909419
19 May 2014
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4862194
5 March 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4810792
30 January 2012
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4232233
26 December 2011
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4214070
Deficiency record · 16
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 19 March 2020
Resolved
The purpose of the regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met. Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. During testing of the EDG emergency quick closing valve, PSCO noted the handle outside the space separate from the steel cable. Attempts were made by the crew to pull the cable without success. Additionally, once the quick closing valve was closed, the EDG continued to operate with minimal signs of fuel starvation. PSCO believes that these arrangements present a hazards condition on board in the event of fire or emergency.
74 SOLAS(14)II-2/14.1.1
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 19 March 2020
Resolved
The company should establish procedures to ensure that the ship is maintained to conform with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The objective evidence in the deficiencies listed herein indicates a serious failure or lack of effectiveness of the implementation of the ISM CODE. Therefore the COTP questions the adequacy and or implementation of the vessels safety management system. An external safety management audit is recommended to be carried out within 30 days by the administration or the RO to determine if the vessel is operating in accordance with the ISM CODE. Provide decision to the USCG before leaving port. Vessel could not provide PSCO with maintenance check list for the EDG or quick closing valves. In addition, provided PSCO maintenance schedule for the lifeboat, which indicated SOLAS tape replacement but objective evidence indicated otherwise.
74 SOLAS(14)XI-1/4.1 ISM Code 10.1
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 19 March 2020
Resolved
Means shall be provided to control leaks of flammable liquids. PSCO noted fuel leaking from the quick closing valves in the purifier room for the HFO service tanks #1 and #2, creating a hazard.
74 SOLAS(14)II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 March 2020
Resolved
Ignition sources shall be separated from combustible materials and flammable liquids. PSCO noted empty paint cans and unmarked plastic drum of chemicals in the BOSN locker creating a potential fire hazard.
74 SOLAS(14)II-2/4.1.5
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 March 2020
Resolved
Maintenance, testing, and inspections of lifesaving appliances shall be carried out based on the guidelines developed by the organization and in a manner having due reguard to ensure reliability of such appliances. PSCO noted the retro-reflective tape on the lifeboat both port and starboard sides were not maintained and required replacement.
74 SOLAS(14)III/20.3.3.1
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 19 February 2020
Resolved
04114 - The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency. Generator does not have enough fuel for 18 hours of continuous operation.
74SOLAS(04)II-1/43.2
30AC
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 February 2020
Resolved
70126-Means shall be provided to control leaks of flammable liquids. PSCO observed fuel leaking from the valve from the fuel tank to the emergency generator and a valve on the # 2 HFO tank as well as excessive oil accumulated under the main engine. There was also oil stored in buckets in the engine room and purifier room and excessive oil on deck in the purifier room.
74 Solas(14)II-2/4.1.1
30AC
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 February 2020
Resolved
07110- Fire Protection system and fire fighting systems and appliances shall ne maintained ready for use. PSCO observed wasted gaskets on most of the firehoses and nozzles on deck.
74 Solas (14)II-2/14.1
17AC
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 19 February 2020
Resolved
15109- The company should ensure that inspections are held at appropriate intervals, any non-conformity is reported. Appropriate corrective action is taken and records of these activities are maintained. Vessel provided PSCO's with documentation showing weekly inspections are being conducted on fire fighting equipment and the main engine, but objective evidence proved otherwise. The Chief Engineer stated there were no checklist for weekly inspections of the emergency generator.
74Solas(14)IX/3.1
ISM Code 10.2
30AC
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 19 February 2020
Resolved
09219- All electrical appliances shall be so installed as to not cause injury when handled or touched in the normal manner. PSCO observed insulation missing on the valve remote console in the engine control room and exposed wire in the CO2 room switchboard shall be so arranged as to give easy access as may be needed to apparatus and equipment. PSCO observed equipment, supplies and various boxes preventing access to switchboards in the engine control room.
74 Solas(04)II-1/45.1.3
17AC
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 February 2020
Resolved
09209-Switchboard shall be so arranged as to give easy access as may be needed to apparatus and equipment. PSCO observed equipment, supplies and various boxes preventing access to switchboards in the engine control room.
74 Solas(04)II-1/45.2
17AC
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 19 February 2020
Resolved
09207-The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations. PSCO observed water flooding in laundry room deck and various inoperable lights in crew cabins.
74 Solas (14) I/11(a)
17AC
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Other (ISM)
Issued 19 February 2020
Resolved
15113- Due to the above objective evidence, the PSCO questions the adequacy of the implantation of the vessels safety management system. Recommend an external audit.
74 Solas (14) IX/3.1
50AC
Lifesaving › Lifebuoys › Not on Board
Issued 26 December 2011
Resolved
Cargo ships carry not less than the number of lifebuoys complying with the requirements of regulation 7.1 and section 2.1 of the code. One lifebuoy located forward of #2 crane pedestal is missing. 74 SOLAS (09 Cons) Ch. III/32.1.1. 70c
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 26 December 2011
Resolved
The cargo securing manual shall be approved by the administration, and be drawn up to a standard of the relevant guidelines developed by the organization. The cargo securing manual could not be made available for inspection upon the request of the USCG. 74 SOLAS (09 Cons) Ch VI/5.6, 70c
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 26 December 2011
Resolved
Non-Tank Vessel Response Plan required by 33CFR155 subpart G shall be readily available. Non-Tank Vessel Response Plan is approved by CG HQ, but not onboard.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.