← All vessels
OSLO BULK 11
Freight Ship · General Dry Cargo Ship class · Built 2010s · USCG Heartland District (CGD-H) · Other hulls named OSLO BULK 11
OSLO BULK 11 is a 2011 freight ship. The Coast Guard has recorded 31 inspections since 2011, most recently in May 2026, along with 21 deficiencies and 9 operational controls.
Records from 2011 to 2026. Most recent: inspection, 1 May 2026.
- Built
- 2011
- Last inspected
- 1 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 21 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9583043 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V2HZ4
1162871
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-1162871
Inspections, by type
…with no type recorded9
Years with a record
9 calendar years (2011–2026)
The 31 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it5630 - Convention (Subpart B), Gross Ton
2883 - Convention (Subpart B), Net Ton
8265 - Dead Weight, Metric Ton
11455 - Displacement, Metric Ton
2883 - Convention (Subpart B), Net Ton
8265 - Dead Weight, Metric Ton
11455 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 31
1 May 2026
PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8357108
5 February 2026
Deficiency Check · PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8303618
6 December 2025
Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8277632
12 November 2025
PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8265685
7 November 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8265791
28 October 2025
In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8259839
22 October 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8257306
22 May 2025
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8137625
4 April 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8105078
22 February 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8082938
6 February 2025
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8075707
10 December 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8044506
6 December 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8044393
12 November 2024
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8031409
24 October 2024
PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8019825
17 June 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7937204
1 May 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7675284
4 April 2023
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7659796
12 March 2023
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7649583
2 March 2023
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7642823
25 August 2022
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7540743
22 August 2022
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7540753
8 August 2022
Deficiency Check · PSC A
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7527766
21 October 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6027402
8 August 2016
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5961966
1 June 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5894388
12 April 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5852871
6 April 2016
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5848467
25 June 2014
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4899202
27 February 2012
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4250398
18 December 2011
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4205963
Deficiency record · 21
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 February 2026
Resolved
The fire resistance of doors shall be equivalent to that of the division in which they are fitted, this being in accordance with the fire test procedures code... doors fitted in boundary bulkheads of machinery spaces of category "A" shall be reasonably gastight and self-closing. PSC observed the two fire resistant doors in the escape trunk were missing or had regarded seals rendering them unable to meet the standard.
74SOLAS2009 II-2/4.2.1
17A/C
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 5 February 2026
Resolved
Guardrails fitted on superstructure and freeboard decks shall have at least three courses. Freeboard guardrails on port side adjacent to hold number two was missing the bottom course from one section.
ILLC ch.I-25(3)
10C
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 5 February 2026
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSC observed exposed wiring coming from an unsealed junction box in the engine room.
74SOLAS2004 II-1/40.1.3
10C
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 November 2025
Resolved
SHIPS SHALL BE DESIGNED, CONSTRUCTED, AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY. PSCO OBSERVED ENGINE CONTROL ROOM ALARMS NOT OPERATING AS INTENDED BY NOT REPEATING ALL ALARMS.
74 SOLAS (04) II-1/3-1
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 November 2025
Resolved
HYDRAULIC POWER-OPERATED STEERING GEAR SHALL BE PROVIDED WITH THE FOLLOWING: A FIXED STORAGE TANK HAVING SUFFICIENT CAPACITY TO RECHARGE AT LEAST ONE POWER ACTUATING SYSTEM... THE STORAGE TANK.. CAN BE READILY RECHARGED... PSCO OBSERVED LEAKAGE ON STEERING GEAR RESULTING IN EMPTY RESERVOIR AND ACCUMULATION OF OIL.
74 SOLAS (04) II-1/29.12.3
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 November 2025
Resolved
THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED ACCUMULATION OF OIL ON PIPING AND LAGGING IN ENGINE ROOM.
74 SOLAS (09) II-2/4.1.1
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 November 2025
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 November 2025
Resolved
THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: THERMAL INSULATION OR BOUNDARIES SHALL HAVE DUE REGARD TO THE FIRE RISK OF THE SPACE AND ADJACENT SPACES. PSCO OBSERVED DEGRADED INSULATION FOR STRUCTURAL FIRE PROTECTION IN ENGINE ROOM.
74 SOLAS (09) II-2/9.1.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 November 2025
Resolved
WHERE A FIXED GAS FIRE-EXTINGUISHING SYSTEM IS USED, OPENINGS WHICH MAY ADMIT AIR TO, OR ALLOW GAS TO ESCAPE FROM, A PROTECTED SPACE SHALL BE CAPABLE OF BEING CLOSED FROM OUTSIDE THE PROTECTED SPACE. PSCO OBSERVED TEMPORARY FIRE CAPS ON CARGO HOLD DRAIN LINES.
74 SOLAS (09) II-2/10.4.2
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 November 2025
Resolved
SHIPS SHALL BE DESIGNED, CONSTRUCTED, AND MAINTAINED IN COMPLIANCE WITH THE STRUCTURAL, MECHANICAL AND ELECTRICAL REQUIREMENTS OF A CLASSIFICATION SOCIETY. PSCO OBSERVED AN UNAPPROVED ELECTRICAL DISPLAY INSTALLED IN THE ENGINE CONTROL ROOM.
74 SOLAS (04) II-1/3-1
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 November 2025
Resolved
THE OPERATOR OF A VESSEL WITH A CAPACITY OF 50 OR MORE BARRELS OF OIL... SHALL PROVIDE TRANSFER PROCEDURES... PSCO OBSERVED NO TRANSFER PROCEDURES ON BOARD.
33 CFR 155.720
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 May 2025
Resolved
09209 - Electrical
Where necessary, non-conducting mats or gratings shall be provided at the fronta and rear of the main and emergency switchboards. PSCO observed no non-conducting mats surrounding engine room switchboards.
74 SOLAS (2004) Ch. II-1/Reg. 45.2
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 May 2025
Resolved
07109 - Fixed fire extinguishing installation
Fire protection systems and fire-fighting systems and appliances shall be maintained ready for use. PSCO observed impeded accesss to CO2 room. Hatch cover was exceptionally difficult to open and required assistance of a second crew member.
74 SOLAS (2009) Ch. II-2/ Reg. 14.1.1
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 10 December 2024
Resolved
The owner, master, or person in charge shall ensure that: the vessel's anchors are ready for letting go. Vessel is missing port side anchor.
33 CFR 164.11(o)
705ac: anchor to be replaced in accordance with due date given by Flag and Class of 06 Jan 2025
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 12 November 2024
Resolved
AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9 OR 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURAL ARRANGEMENTS, MACHINERY, EQUIPMENT AND OTHER ITEMS COVERED BY THE SURVEY, WITHOUT THE SANCTION OF THE ADMINISTRATION. VESSEL REPORTED THAT IT LOST PORT SIDE ANCHOR DURING INBOUND TRANSIT TO THE PORT OF SAVANNAH. PSCO OBSERVED ANCHOR MISSING.
74 SOLAS (20) I/11(B)
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 October 2024
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE-SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. PSCO OBSERVED THE RESCUE BOAT UNABLE TO START. PSCO OBSERVED INITIAL START OF RESCUE BOAT BUT UNABLE TO ENGAGE REVERSE. AFTER MAINTENANCE THE CREW COULD NOT RESTART THE RESCUE BOAT ENGINE FOR 20 MINUTES. FUEL FILTER WAS REPLACED BY CREW. PSCO OBSERVED OPERATIONAL TEST OF RESCUE BOAT IN ACCORDANCE WITH THE REGULATIONS.
74SOLAS(20) III/20.2
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 April 2023
Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designated, constructed, and maintained in compliance with structural, mechanical and electrical requirements of class society recognized by the Admin in accordance with the provisions of reg. XI-1/1, or with applicable national standards of the Admin which provide an equivalent level of safety. PSCO observed deadened electrical cable center forward of cargo hatch one still connected to distribution panel. PSCO also observed wasted junction box cover for shore side electrical main connection. (74 SOLAS(14) II-1/3-1)
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 April 2023
Resolved
This regulation applies to all ships. Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. PSCO observed 07 un spliced lines on life ring buoys. Secured by blue electrical tape. (74 SOLAS (14) III/20.2)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 April 2023
Resolved
Daily service tanks having a capacity of 500L and above shall be capable of being closed from a safe position outside the space. PSCO observed broken cable affixed to the quick closing valve. Repairs were made. (74 SOLAS (04) II-2/4)
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 August 2022
Resolved
Each liferaft or group of liferafts shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the code so that each floats free and if inflatable, inflates automatically when the ship sinks. The port and starboard Life raft's hydrostatic release's were improperly setup.
74SOLAS 09 CONS
CH III Reg 13.4.2
Rectify Deficiencies Prior to Departure; To the satisfaction of the Coast Guard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 8 August 2022
Resolved
Cargo ships shall carry one or more totally enclosed lifeboats complying with the requirements of section 4.6 of the Code. The rations shall be packed in permanently sealed metal containers or vacuum packed in a flexible packaging material. The lifeboat's rations were not vacuum sealed.
74SOLAS 09 CONS
CH III Reg 31.1.1.1
LSA CODE 4.1.5.1.18
Rectify Deficiencies by 07Sept22. To the satisfaction of the Coast Guard.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National