← All vessels
PS TRIESTE
PS TRIESTE is a 2011 tank ship. The Coast Guard has recorded 12 inspections since 2016, most recently in April 2026, along with 2 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 18 April 2026.
- Built
- 2011
- Last inspected
- 18 April 2026
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 2 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9473054
9HA2823
1163110
Flag
MALTA
Maury page id
psix-1163110
Inspections, by type
…with no type recorded3
Years with a record
6 calendar years (2016–2026)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it60205 - Convention (Subpart B), Gross Ton
32143 - Convention (Subpart B), Net Ton
125524 - Displacement, Metric Ton
107546 - Dead Weight, Metric Ton
32143 - Convention (Subpart B), Net Ton
125524 - Displacement, Metric Ton
107546 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 12
18 April 2026
PSC B · COC-TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8351776
28 February 2025
COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8085906
10 March 2024
PSC B · COC-TVE Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7876605
3 February 2024
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7860077
13 September 2023
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7802663
12 September 2023
COE-Offshore
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7790085
26 February 2023
PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7638325
28 October 2018
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6569852
18 October 2018
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 6561727
19 July 2016
Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5939643
18 July 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5945527
13 July 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5939891
Deficiency record · 2
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 18 October 2018
Resolved
07109 -Fixed fire extinguishing systems shall be installed, having due regard to the fire growth potential of the protected spaces, and shall be readily available. During exam of engine room fixed foam system, PSCO observed that the manufacturer instructions stated the system be set in an automatic mode. The system was set in manual mode as per shipboard instructions. 74SOLAS2009 II-2/10.1 50a
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 October 2018
Resolved
07106 - Fixed fire detection systems shall be periodically tested by means of equipment producing hot air, smoke, or other phenomena associated with incipient fires to which the detector is designed to respond. During the fire alarm test it was discovered that the flame detection testing lamp was non-functional. The crew had been testing the flame detectors with an open flame sourced from a can of contact cleaner attached to a pole with wire. 74SOLAS2009 II-2/7.3.2 50a
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National