← All vessels
HARVEY ENERGY
Industrial Vessel · Miscellaneous Vessel class · Built 2010s · USCG Heartland District (CGD-H) · Other hulls named HARVEY ENERGY
HARVEY ENERGY is a 2015 industrial vessel. The Coast Guard has recorded 23 inspections since 2011, most recently in June 2026, along with 10 deficiencies and 2 casualty investigations between 2023 and 2025.
Records from 2011 to 2026. Most recent: inspection, 29 June 2026.
- Built
- 2015
- Last inspected
- 29 June 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2023–2025
Identity
1243697
9654220 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
KHEK
1163460
Flag
UNITED STATES
338225000
Maury page id
psix-1163460
Inspections, by type
…with no type recorded2
Years with a record
13 calendar years (2011–2026)
The 23 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Documentation record
Registered dimensions (L × B × D)278.4 ft × 64.0 ft × 24.5 ft
Registered tonnagegross 4,458 / net 1,700
ITC dimensions (L × B × D)278.4 ft × 64.0 ft × 24.5 ft
ITC tonnagegross 4,458 / net 1,700
BuilderGULF COAST SHIPYARD GROUP INC · GULFPORT, MS, UNITED STATES · built 2015
Hull materialSteel
PropulsionDual Fuel (Diesel & Liquefied
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portFOURCHON, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 December 2025 · expires 31 December 2026
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4458 - Convention (Subpart B), Gross Ton
1700 - Convention (Subpart B), Net Ton
1700 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
KHEKMMSI 338225000 · active · compulsorily equipped · granted 2 August 2024, expires 1 October 2034
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 23
29 June 2026
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8433826
17 April 2026
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8325079
1 August 2025
Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8200312
1 August 2025
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8235460
3 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8174274
17 March 2025
ACP COI Oversight · Re-Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8090163
11 January 2025
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8062185
13 May 2024
Annual Inspection · ACP COI Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7911754
5 June 2023
Annual Inspection · ACP Annual Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7704382
29 April 2023
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7677915
28 April 2023
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7681968
9 May 2022
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7681311
16 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7262460
6 May 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7190592
8 October 2020
Construction Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7074243
7 April 2020
MARPOL Annex VI Survey · MARPOL Annex V Examination · MARPOL Annex I Examination · ACP COI Oversight · Administrative Inspection · MTSA/ISPS Verification · Annual Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6936315
25 July 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6762016
7 May 2019
Administrative Inspection · ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6678647
14 May 2018
Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6414062
3 May 2017
Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6137430
29 April 2016
ACP Annual Oversight · Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5865801
7 March 2014
Construction Oversight
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 4811707
13 December 2011
MARPOL Annex II Examination · COI Inspection · Welding Related Inspections Qualification Testing · Deadweight Survey · Construction Oversight · Initial Construction-Excluding Oversight · Inclining Experiment · Ballast Water Examination · Hull Examination · MTSA/ISPS Verification · Examination of Repairs · ACP Handover Survey · Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4207187
Deficiency record · 10
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 17 March 2025
Resolved
Electrical installations shall ensure the safety of passengers, crew and ship from electrical hazards. An extension cord within the Nitrogen Generator Space was found to be spliced into an overhead armored cable to power a portable blower.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 17 May 2024
Resolved
Where cables which are installed in hazardous area introduce the risk of fire or explosion in the event of an electrical fault in such areas. special precautions against such risk shall be taken. Wire on blower motor for bunkering station were exposed. SOLAS 74 2020 (CONS) Chapter II-1 45.5.4
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 May 2024
Resolved
Fixed fire detection and fire alarm system required shall be designed and the detectors positioned to rapidly detect the onset of fire. Fire detector could not activate. SOLAS 74 2020 (CONS) II-2 chapter 7.4.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 April 2023
Resolved
Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration.
Vessel has sustained damage to the 03 flybridge due to a flash fire caused by an unknown source. Identify the source that ignited the flash fire and notify OCMI for approval, and submit repair proposal and conduct repairs to all damage to the satisfaction of a USCG Marine Inspector.
Vessel authorized to shift piers within [name withheld] Dock in daytime operations only.
SOLAS 14 II-1/3.1
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 6 May 2021
Resolved
The angular position of the rudder shall be recognizable in the steering gear compartment. The port rudder angle indicator for the steering control station was inoperable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 May 2021
Resolved
Steering gears control shall be provided in the steering gear compartment and must be in satisfactory condition. The display on the Port Control station was removed and needs to be replaced after programming. 74SOLAS(14) II-1/29.7.1 & ABS 7.2.1.1.3
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 6 May 2021
Resolved
Any required automatic sprinkler, fire detection and fire alarm system shall be capable of immediate operation at all times and no action by the crew shall be necessary to set it in operation. The water mist system showed a pump control fault for phase/volt/overloads and was required to be reset during the inspection. The fire detection system was overloaded and required to be reset during the inspection. 74SOLAS(14) 7.2.2 & FSS 8.2.5.1.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 6 May 2021
Resolved
Vessel shall ensure that the safety of the ship is not impaired in any sea conditions. Marine Inspector was able to see daylight through the steering room emergency escape hatch when closed and secured.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 April 2020
Resolved
Each vessel must be designed and constructed to minmize fire hazards, as far as reasonable and practicable. Vessel has an issued MLV remediation plan for structural fire protetion of vessel. Vessel shall provide evidence of compliance with approved remediation plan.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 14 May 2018
Resolved
Vessel is required to comply with the interim guidlines on safety for natural gas fueled engine installations on ships. The cold box was found to have multiple pin holes leaks presenting a hazard. Complete repairs to the satisfaction of the attending USCG MI.
Casualty record · 2
28 April 2023Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 7681968
1 August 2025Routine · role: Involved in a Marine Casualty · activity 8235460
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.