Records from 2012 to 2024. Most recent: inspection, 12 February 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
12 February 2024
COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7863401
9 October 2023
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7802620
1 December 2022
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7602072
13 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576919
19 October 2021
Drydock Exam · Deficiency Check · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7335117
2 August 2021
Administrative Inspection · In-Service Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7272590
13 October 2020
Administrative Inspection · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7075934
22 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6836530
2 October 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6821428
27 August 2018
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6521394
6 November 2017
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6296154
24 October 2017
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6291743
12 December 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6053893
22 October 2015
Deficiency Check · COI Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5734291
23 July 2015
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5192185
18 August 2014
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4947946
10 January 2012
Administrative Inspection · Deadweight Survey · DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4221743
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 October 2021
Resolved
Fuel lines are single clamped at all connection points. Double clamp all fuel lines.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2021
Resolved 2 November 2021
Resolution: Received photos of double clamped fuel lines.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 October 2020
Resolved
Replace condemned lifejackets to make full complement of 30 adult life jackets. 04 jackets needed. Passenger count reduced to 24 until rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2020
Resolved 27 October 2020
Resolution: Received photos via e-mail of new life jackets.
Construction/Loadline › Hull › Hull Plating
Issued 22 October 2015
Resolved
Reinforce bow areas prior to conducting beaching operations.
Action required: 705 - Other - as specified
Resolved 20 November 2015
Resolution: Own/Oper welded on beaching wear plates.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 October 2015
Resolved
Provide 100 asprin in first aid kit on board vessel.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 20 November 2015
Resolution: Provided new 100 count bottle onboard.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 October 2015
Resolved
Replace / Repair port (red) light cover.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 20 November 2015
Resolution: Replace port nav light with new one.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 22 October 2015
Resolved
Post COI on board vessel, visible to passengers.
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 20 November 2015
Resolution: Will post new COI once rcvd in the mail.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 23 July 2015
Resolved
Label all reversible Type I lifejackets onboard.
Action required: 705 - Other - as specified
Due 23 July 2015
Resolved 23 July 2015
Resolution: Reversible lifejackets labeled on both sides.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 August 2014
Resolved
Vessel has gone past it's 90 days after window to complete it's Annual Inspection. Vessel is restricted from carrying passengers until vessel completes the required Annual Inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2014
Resolution: Completed Annual Inspection