Records from 2015 to 2018. Most recent: inspection, 6 July 2018.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 November 2015
Resolved
CODE 1400: The machinery, boilers, pressure vessels, and associated piping shall be of a design and construction for the service for which they are intended. The oily water seperator has a 40cm patch which leaks during the second stage of operation. Ship has no documentation of when repair was made or by whom. 74 SOLAS (14) II-2/26 17AC
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2015
Resolved 18 November 2015
Resolution: Corrected to the satisfaction of class.
Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 12 November 2015
Resolved
CODE 0610: Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. The free fall lifeboat had its drinkable water cans replaced with large 10 L containers which were stowed on two seats in the front of the boat. It is unknown when the change was made and by whom. 74 SOLAS (14)III/20, 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2015
Resolved 18 November 2015
Resolution: Corrected to the satisfaction of class.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 12 November 2015
Resolved
Code 0715: Detectors shall be locatedc for optimum performance. Next to the engine workshop, in the storage room, there is only one smoke detector in the space that may not be sufficient because of the crew addition of a loft built for storage that is blocking the air flow to the detection system. 40AC
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 November 2015
Resolved 18 November 2015
Resolution: Corrected to the satisfaction of class.
Construction/Loadline › Penetrations › Pipe Flange
Issued 12 November 2015
Resolved
Code 0340: After Survey has been completed, no change shall be made without the sanction of the administration. In the Air Conditioning Room, the crew welded on a flushing line to the grey water line traveling through the space. 74 SOLAS (14) 1/II, 40ac
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 November 2015
Resolved 18 November 2015
Resolution: Corrected to the satisfaction of class.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pump Power Supply
Issued 11 November 2015
Resolved
Code 1400: The machinery, boilers, pressure vessels, and associated piping shall be of a design and construction for the service for which they are intended. The high pressure water mist system was found in local control when it should have been ready for operation in remote control. See Vessel Narrative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2015
Resolved 18 November 2015
Resolution: Corrected to the satisfaction of class.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 11 November 2015
Resolved
CODE 2510:Vessel must maintain a Ballast Water Management Plan that has been developed specifically for the vessel that will allow those responsible for the plan to understand and follow it. Vessel currently does not have a biofouling management plan. Vessel has been using two different unapproved forms since 2011. Sediment Documentation from Section 9 is being recorded in the wrong places. 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 November 2015
Resolved 18 November 2015
Resolution: Corrected to the satisfaction of class.
Operations/Management › EPA Vessel General Permit (VGP) › 4.1.1.1-Documentation Routine Vessel Inspection
Issued 11 November 2015
Resolved
2510: Vessl company has submitted their Notice of Intent. However they could not provide a copy of the approval letter. The crew did not conduct a weekly inspection. [name withheld], [phone withheld], [email withheld], Sector San Francisco
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 November 2015
Resolved 18 November 2015
Resolution: Corrected to the satisfaction of class.