Records from 2016 to 2023. Most recent: inspection, 29 April 2023.
Inspection history · 10
29 April 2023
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7672102
2 November 2022
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7588029
1 November 2022
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7587377
26 January 2021
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7130539
17 March 2020
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6929013
10 March 2018
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6369430
19 January 2018
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6340366
2 February 2017
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6081505
5 February 2016
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5810107
21 January 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5798818
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 15 March 2018
Resolved
0610 - LIFEBOATS - THE FREEFALL LIFEBOAT SHALL BE LOWERED AND MANEUVERED IN THE WATER AT LEAST ONCE EVERY THREE MONTHS. PSCO IDENTIFIED THE VESSEL HAS NOT MANEUVERED THE LIFEBOAT SINCE 28NOV2017
SOLAS74(2014 CONS) CH III REG. 19.3.3.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2018
Resolved 1 November 2022
Resolution: All sat.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 15 March 2018
Resolved
0999 - OTHER(SAFETY IN GENERAL) - ELECTRICAL SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW, AND SHIP FROM ELECTRICAL HAZARDS WILL BE ENSURED. PSCO OBSERVED WATER LEAKING FROM 02 SPRINKLER NOZZELES ONTO THE NUMBER 1 AND 2 FUEL OIL PURIFIERS
74 SOLAS (09 CONS) CH II-1 REG 40.1.3
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 15 March 2018
Resolution: CORRECTED ON THE SPOT
Lifesaving › Rescue Boat › Rudder/Tiller/Steering
Issued 10 March 2018
Resolved
0615 - RESCUE BOATS - RESCUE BOATS SHALL BE LAUNCHED EVERY MONTH WITH THEIR ASSINGED CREW ABOARD AND MANEUVERED IN THE WATER, IN ALL CASES IT SHALL BE CONDUCTED EVERY THREE MONTHS. PSCO IDENTIFIED THE VESSEL HAD NOT MANEUVERED THE RESCUE BOAT IN THE ATER SINCE 22NOV2017
SOLAS 74 (2014 CONS) CH III REG 19.3.3.6
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 April 2018
Resolved 1 November 2022
Resolution: All sat.
Documentation › Logs/Records › Oil Record Book
Issued 10 March 2018
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 15 March 2018
Resolution: CORRECTED ON THE SPOT
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 21 January 2016
Resolved
0740: There shall be immediate water delivery from the fire main system at a suitable pressure, either by remote starting of one of the main fire pumps with remote starting from the navigation bridge and fire control station. Crew was unable to supply water immediately when the emergency fire pump was energized. It took the crew approximately 30 minutes to prime the emergency fire pump. 17 ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2016
Resolution: Recieved class report attesting to the working order of the emergency fire pump.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 21 January 2016
Resolved
0715: The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction of the administration by means of equipment producing hot air at the appropriate temperature. Crew used lighter while testing heat detector in the engine room which is not in accordance with the manufacturer's instructions. 74 Solas (2014) II-2/7.3.2 16ac
Action required: 705 - Other - as specified
Due 4 February 2016
Resolved 5 February 2016
Resolution: Recieved receipt from the vessel showing purchased heat detection testing equipment.