MAURY USCG vessel records
← All vessels

JAY C

JAY C is a 2012 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in July 2026, along with 7 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 21 July 2026.

Built
2012
Last inspected
21 July 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 July 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG4487
1164322
Flag
UNITED STATES
Maury page id
psix-1164322

Documentation record

Registered dimensions (L × B × D)47.0 ft × 17.0 ft × 8.5 ft
Registered tonnagegross 45 / net 36
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderB & T WELDING LLC · BOOTHVILLE, LA, UNITED STATES · built 2012
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it45 - Simplified, Gross Ton
36 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 13

21 July 2026 Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8354642
19 June 2026 Administrative Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8408538
28 August 2025 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8157446
25 September 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7982548
27 September 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7794678
27 June 2022 COI Inspection · Drydock Exam · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7458306
17 May 2021 Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7179798
3 September 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7044847
26 August 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6794775
23 July 2019 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6759970
3 August 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6492177
26 June 2017 Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6186991
2 August 2016 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5959220

Deficiency record · 7

03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 19 June 2026 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its COI giving consideration to provisions for a seaworthy hull. MI received report of cracked welds in the railing following an allision with a foreign vessel, causing breach of watertight envelope. Repair to the satisfaction of the attending MI. 46CFR177.100
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 June 2026
Resolution: Satisfactory NDT during repair check
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 25 September 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. MI found a cracked weld on bow of vessel 46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2024
Resolved 21 October 2024
Resolution: Received pictures of weld caps, rewelded. all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 September 2024 Resolved
A voltmeter and an ammeter which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. MI found SSDG panel unreadable. 46 CFR 183.320(c)
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2024
Resolved 21 October 2024
Resolution: Received Pictures of new panel. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 September 2024 Resolved
Each generator must have a nameplate attached to it containing the information required by Article 430 of NFPA 70. MI found the SSDG's name plate worn and unreadable. MI cannot determine whether overcurrent is set properly or the design temperature rating. 46 CFR 183.320(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2024
Resolved 21 October 2024
Resolution: Received pictures of new plate displaying amp temp 125celius and 45.8 amp with installed over current protection of 50amp. All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 September 2024 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Wire penetrations in engine rm forward bulkhead on port side were not watertight. 46 CFR 179.320(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2024
Resolved 21 October 2024
Resolution: Received pictures of water tight cable transit. All sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 September 2024 Resolved
The provisions of Part III of Title III of the Communication Act require United States vessels which transport more than six passengers for hire while such vessels are being navigated on any tidewater within the jurisdiction of the United States adjacent or contiguous to the open sea, or in the open sea to carry a radiotelephone installation complying with this subpart. Vessel did not have a valid radiotelephony certificate. 47 CFR 80.901
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2024
Resolved 25 September 2024
Resolution: Pictures received, All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 25 September 2024 Resolved
Fire hazards to be minimized. The general construction of the vessel must be such as to minimize fire hazards. MI observed machinery space hatches to be missing gaskets. 46 CFR 177.405(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 October 2024
Resolved 21 October 2024
Resolution: Received pictures of renewed gaskets.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.