ATLANTIC NORTH

ATLANTIC NORTH is a 2012 freight ship. The Coast Guard has recorded 14 inspections since 2023, most recently in February 2026, along with 15 deficiencies and 10 operational controls.

Records from 2023 to 2026. Most recent: inspection, 23 February 2026.

Built
2012
Last inspected
23 February 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 February 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2023–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9575981
V7A3792
1164622
Flag
MARSHALL ISLANDS
Maury page id
psix-1164622

Documentation record

Tonnage as PSIX records it22456 - Convention (Subpart B), Gross Ton
34993 - Dead Weight, Metric Ton
12060 - Convention (Subpart B), Net Ton
45900 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

23 February 2026 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8314400
21 February 2026 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8313699
19 February 2026 PSC A
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8309196
20 June 2025 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8166275
15 June 2025 In-Service Inspection · PSC B · Administrative Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8159427
16 April 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8112783
8 January 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8060010
24 October 2024 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8023938
28 April 2024 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7902803
12 April 2024 PSC B · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7894291
11 April 2024 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7893481
11 April 2024 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7893632
5 April 2024 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7890465
11 August 2023 Deficiency Check · PSC B · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7762250

Deficiency record · 15

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 February 2026 Resolved
The purpose of this regulation is to prevent the ignition of combustion materials of flammable liquids. Means shall be provided to control leaks of flammable liquids. PSCO observed oil underneath the incinerator. RO must attest to the operation of incinerator prior to use. SOLAS 74(2009)II-2/4.1.1
Action required: 705 - Other - as specified
Resolved 20 February 2026
Resolution: PSC NOLA received a class report from issuing entity satisfying the requirement.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 14 July 2025 Resolved
MINIMUM SAFE MANNING CERTIFICATE SHALL BE IN COMPLIANCE WITH THE CONVENTION PRIOR TO THE MOVEMENT OF THE VESSEL. FLAG SHALL PROVIDE ATTESTATION OF THE CREW COMPETENCE AND FITNESS PRIOR TO VESSEL MOVEMENT. STCW 2017 I/2.11
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 July 2025
Resolution: MSU SAVANNAH RECEIVED A MASTER STATEMENT FROM THE VESSEL STATING THAT THE VESSEL MEETS THERE MINIMUM SAFE MANNING REQUIRMENTS.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 14 July 2025 Resolved
Performance of crew members assigned fire-fighting duties shall be periodically evaluated by conducting on-board training and drills to identify areas in need of improvement, to ensure competency in fire-fighting skills is maintained, and to ensure the operational readiness of the fire-fighting organization. PSCO safety concerns and lack of crew competency while conducting fire drill in the emergency generator space 10JUL25. Upon re-inspection on 14JULY25, prior to the fire drill, crew members were fatigued and one member of the crew left the vessel for medical attention regarding heat exhaustion and dehydration. Flag to attest to crew training, completion of fire frills, and address unsatisfactory accommodation space. 74solas(09) II-2/1.5.2.2.3 STCW 2017 I/6 ILO/MLC 2006
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 February 2026
Resolution: PSC NOLA received a proper documentation from issuing entity satisfying the requirement.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 14 July 2025 Resolved
The Company should establish procedures to ensure that the ship is maintained in conformity with the relevant rules and regulations and with any additional requirements which may be established by the company. External audit received by the Class Society BV noted 5 Major Nonconformities, an internal audit from the company shall be completed to address the appropriate corrective actions from all nonconformities.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 February 2026
Resolution: PSC NOLA received a proper documentation from RINA satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 July 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs.: fire detection and alarm systems. PSCO observed a non-operative Hyper-mist system and fire detection in the purifier room. No spare were available. A Flag dispensation has been issued for the Hyper-mist and fire detection system for the vessel to sail to the next port in this condition with a manned space for the engine room.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 February 2026
Resolution: PSC NOLA received proper documentation from RINA satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 July 2025 Resolved
Ships shall be providied with fire hoses, the number and diameter of which shall be to the satification of the administration. PSCO observed inadequate number of fire hoses in accordance with the fire controll plan. 74SOLAS(09)II-2/15.2.4.1
Action required: 10 - Deficiency Rectified
Resolved 14 July 2025
Resolution: Verified by PSCO and RO
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 June 2025 Resolved
The Company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the Company. The technical and/or operational nature of the deficiencies noted provide evidence of serious failure of the implementation of the ISM Code. External audit received by the class society, BV noted 5 major nonconformities. An internal audit from the company shall be completed to address the appropiate corrective actions from all nonconformities. 74SOLAS(20)IX/3.1 ISM 10.1
Action required: 30 - Ship detained
Resolved 11 July 2025
Resolution: Reviewed Class ISM External audit and recommended company to complete internal audit with in 90 days with class to attest
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 June 2025 Resolved
The safety management system should include procedures ensuring that nonconformities, accidents and hazardous situations are reported to the Company, investigated and analyzed with the objective of improving safety and pollution prevention. PSCO observed that deficiencies 03-09 were not reported to Company. 74SOLAS2020 IX/3.1 ISM Code 9.1
Action required: 30 - Ship detained
Resolved 11 July 2025
Resolution: Class attested to the pollution midigation plan from the cargo hatch ram system. EMFR case for pollution, QI activated NTVRP.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 June 2025 Resolved
The maintenance plan shall include at least the following fire protection systems and fire-fighting systems and appliances, where installed: fire mains. PSCO observed a temporary repair on the fire main and the vessel had no existing maintenance log for recording damaged equipment. SOLAS 2009 II-2 reg 14.2.2.3.1 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2025
Resolution: RECIEVED CLASS REPORT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 June 2025 Resolved
Provision shall be made to facilitate cleaning, inspection and maintenance of main propulsion and auxiliary machinery including boilers and pressure vessels. PSCO observed the feed water piping being taken apart, shutting off hot water supply to the entire ship. SOLAS 2020 II-1/26.7 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2025
Resolution: RECIEVED CLASS REPORT.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boat inventory
Issued 15 June 2025 Resolved
Spares and repair equipment shall be provided for life-saving appliances and their components which are subject to excessive wear or consumption and need to be replaced regularly. PSCO observed peeling and torn rescue quoits in the rescue boat. No spares were available. SOLAS 2020 III/20.5 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2025
Resolution: RECIEVED CLASS REPORT.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 June 2025 Resolved
In addition to the requirements contained elsewhere in the present regulations, ships shall be designed, constructed and maintained in compliance with the structural, mechanical, and electrical requirements of the classification society which is reconized by the Administration in accordance with the provisions of regulation X1-1/1, or with applicable national standards of the Administration which provide an equivalent level of safety. PSCO observed a corroded junction box that was unable to open in way of an emergency shut-off switch for cargo crane operations. SOLAS 2009 II-1/3-1 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 February 2026
Resolution: PSC NOLA received a proper documentation from RINA satisfying the requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 June 2025 Resolved
The lifeboat engine shall be capable of operating for not less than 5 min after starting from cold with the lifeboat out of the water. PSCO observed that the lifeboat engine would not start. SOLAS 2020 III/31.1.2.1 LSA 4.4.6.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2025
Resolution: RECIEVED CLASS REPORT.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 June 2025 Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: fire detection and alarm systems. PSCO observed a non-operative hypermist system and fire detection in the purifier room. No spares were available. A flag dispensation has been issued for the hyper-mist and fire detection system for the vessel to sail to the next port in this condition with a manned space for the engine room. SOLAS 2009 II-2/14.2.1.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 July 2025
Resolution: Recieved class report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 August 2023 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or the persons on board. PSCO's observed Main Engine #6 cylinder leaking water through the spacer o-ring. In addition, PSCO's observed lack of general cleanliness in the engine room. 74 SOLAS (2020) I/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 August 2023
Resolution: Deficiency rectified.