Records from 2013 to 2025. Most recent: inspection, 3 April 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 37
3 April 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8210261
22 November 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8040304
22 November 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8040519
15 October 2024
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8018859
14 October 2024
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8020826
2 June 2024
Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7922088
23 January 2024
In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7853034
29 October 2023
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7822347
17 May 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7694980
25 August 2022
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7566708
6 April 2022
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7431069
27 September 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7321652
31 July 2021
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7274073
10 July 2021
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7256974
9 July 2021
Damage Survey · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7251106
5 May 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7189098
12 August 2020
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7063597
18 July 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7017378
4 October 2019
Damage Survey · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6828584
10 April 2019
Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6660042
25 January 2019
Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6615191
2 August 2018
Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6499440
14 March 2018
Annual Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6372697
1 March 2017
Damage Survey · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6102047
18 January 2017
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6072857
16 May 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5861115
13 May 2015
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5144371
11 May 2015
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5122880
13 September 2014
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4983730
11 August 2014
Damage Survey · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4952511
11 August 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4953121
10 May 2014
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4856523
9 May 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4856316
30 April 2014
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4846112
16 April 2014
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4837587
15 April 2014
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4837300
14 August 2013
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4577380
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 October 2024
Resolved
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2024
Resolved 26 October 2024
Resolution: Technician evaluated steering system. System was reported as functioning as designed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 June 2024
Resolved
The construction and arrangement of a vessel must
allow the safe operation of the vessel in accordance
with the terms of its Certificate of Inspection giving
consideration to provisions for a seaworthy hull.
There are multiple cracks in frame 15 on the number
one end. Submit a plan proposal and implement
approved plan to the satisfaction of the marine
inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 1 August 2024
Resolution: Rcvd report from welder stating adequate repairs were made.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 2 June 2024
Resolved
Any vessel of at least five net tons which engages in [...] coastwise trade (Defined as the transportation of passengers or merchandise between points embraced within the coastwise laws of the United States). Vessel had an expired Certificate of Documentation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2024
Resolved 9 July 2024
Resolution: Confirmed vessel has a valid COD.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 June 2024
Resolved
46 CFR 176.810(b); (b)(1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. (b)(2) The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel had no annual servicing performed on the portable extinguishers, and no documentation for fixed servicing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2024
Resolved 27 June 2024
Resolution: Confirmed maintenance completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2024
Resolved
46 CFR 176.303(b); Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Life buoy on car deck was severely sun damaged and worn, with outer covering peeling off inner foam core.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2024
Resolved 27 June 2024
Resolution: New buoy installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2024
Resolved
46 CFR 176.302; Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2024
Resolved 1 August 2024
Resolution: Item posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2024
Resolved
46 CFR 176.306; When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2024
Resolved 1 August 2024
Resolution: Item posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2024
Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Vessel had no current documentation to show enrollment and testing of crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2024
Resolved 1 August 2024
Resolution: Confirmed test results maintained.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2024
Resolved
You must submit your written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection. Vessel allowed their COI to lapse with no notice to OCMI.
Action required: 10 - Deficiency Rectified
Resolved 27 June 2024
Resolution: COI was completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 June 2024
Resolved
(1)(a) Each stowage container for life jackets must not be capable of being locked. (b) The stowage locations of the personal flotation devices carried in addition to life jackets under § 180.72, must be separate from the life jackets, and such as not to be easily confused with that of the life jackets. Vessel has life jackets stowed in a locked locker with work-vests. Vessel removed work-vests and was instructed to ensure locker is unlocked during operations. Key is located directly adjacent to locker.
Action required: 10 - Deficiency Rectified
Resolved 1 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2021
Resolved
VESSEL REPORTED TRANSMISSION SHIFTING ISSUE WHILE VESSEL WAS AT TERMINAL IN KELLER, WA. TRANSMISSION UNABLE TO STAY ENGAGED IN ONE DIRECTION. MACHINERY AND EQUIPMENT INSTALLED ON EACH VESSEL MUST BE SUITABLE FOR THE VESSSEL AND ITS OPERATION AND FOR THE PURPOSE INTENDED. PRIOR TO DEPARTURE FROM TERMINAL, SUBMIT A TECH REPORT ATTESTING TO SATISFACTORY REPAIRS MADE.
CITE: 46CFR182.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2021
Resolution: Received attestation from crew members that faulty transmission shifting solenoid was replaced with a new solenoid. Tests completed with no issues. ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2021
Resolved
Vessel had vibration on engine, followed by a code: injector mistiming. Vessel may not carry passengers until the engine is fixed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2021
Resolved 13 October 2021
Resolution: Cleared previously via tech report.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 October 2019
Resolved
Make permanent repairs to both #1 and and #2 ends in way of all fractures. Submit repair proposal to the USCG for approval. Reduce cargo load to 1/2 authorized and provide a root cause analysis of the damage. Master use judgement to reduce stresses on the hull with consideration to high winds and seas in excess of 1 foot. 46 CFR 177
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 October 2019
Resolved 5 January 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 2 August 2018
Resolved
In the #1 end engine room behind the switchboard, approx 2" of butt weld found with discontinutity. Monitor weld to ensure it does not spread and leak. Submit repair proposal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 27 September 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 August 2018
Resolved
Replace gasket for aft engine room hatch (#2 end).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 29 August 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 2 August 2018
Resolved
Remove oil, debris, and water from eng room bilges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 29 August 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 2 August 2018
Resolved
Remove and clean all debris and hydraulic oil in #1 and #2 ends steering gear spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 29 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2018
Resolved
In shaft alleys/void spaces remove metal shavings and sand from bilges to prevent blockage for bilge suction.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 29 August 2018
Construction/Loadline › Hull › Hull Plating
Issued 14 March 2018
Resolved
Make temporary repairs to the hull fracture at frame 17 IAW 46 CFR 176.700.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 21 March 2018
Resolution: Divers from Global Dive installed temporary patch (Splash Zone) to the underwater portion of the hull fracture.
Construction/Loadline › Hull › Hull Plating
Issued 14 March 2018
Resolved
Make permanent repairs to the hull fracture at frame 17 46 CFR 176.700.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 13 April 2018
Resolution: Permanent repairs were made with a 12" x 9" insert.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 March 2018
Resolved
Re-install exhaust heat shielding for both main diesel engines 46 CFR 182.430(a).
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 21 March 2018
Resolution: Heat sheilding re-installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 March 2018
Resolved
Install the screw down post type battery in the float light 46 CFR 180.25(a).
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 21 March 2018
Resolution: Correct battery installed.
Construction/Loadline › Hull › Bottom Plating
Issued 13 September 2014
Resolved
Provide repair proposal and complete permanent repairs to bottom hull plating at frame 17 on port side #1 end as discussed.
Action required: 705 - Other - as specified
Due 14 October 2014
Resolved 5 October 2014
Resolution: Permanent repairs completed to hull.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 13 September 2014
Resolved
Crew must monitor void space on #1 end every four hours while in operation until permanent repairs are made to the hull plate.
Action required: 705 - Other - as specified
Due 14 October 2014
Resolved 5 October 2014
Resolution: Permanent repairs made to the hull.
Engineering › Steering Gear System › Chain
Issued 11 August 2014
Resolved
Feedback chain retention bolt failed. Replace with factory approverd equipment.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 18 May 2015
Resolution: Feedback chain arrangement replaced with factory equipment.
Engineering › Steering Gear System › Power Unit
Issued 10 May 2014
Resolved
Washington [name withheld] reported that the vessels steering system on the #1 helm/#2 steering end had the rudder move hard port without giving the command. Troubleshoot and make required repairs to make system fully operational.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2014
Resolution: Rolls-Royce representatives were unable to replicate problem. System is operating within normal parameters.