MAURY USCG vessel records
← All vessels

SANPOIL

SANPOIL is a 2013 passenger barge (inspected). The Coast Guard has recorded 37 inspections since 2013, most recently in April 2025, along with 26 deficiencies and 6 casualty investigations between 2014 and 2024.

Records from 2013 to 2025. Most recent: inspection, 3 April 2025.

Built
2013
Last inspected
3 April 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 3 April 2025
…with no type recorded9
Operational controls None recorded without a removal date
Years with a record 13 calendar years (2013–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1164631
Flag
UNITED STATES
Maury page id
psix-1164631

Documentation record

Registered dimensions (L × B × D)109.6 ft × 45.7 ft × 11.5 ft
Registered tonnagegross 97 / net 65
ITC dimensions (L × B × D)109.6 ft × 45.7 ft × 11.5 ft
ITC tonnagegross 191 / net 66
BuilderFOSS RAINIER SHIPYARD · RAINER, OR, UNITED STATES · built 2013
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portKELLER, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 April 2026 · expires 31 May 2027
Service, as the file records itPassenger Barge (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
191 - Convention (Subpart B), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
66 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

37 inspections, each with its date, unit and type; 26 deficiencies with the resolution recorded against each; 6 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 37

3 April 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8210261
22 November 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8040304
22 November 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8040519
15 October 2024 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8018859
14 October 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8020826
2 June 2024 Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7922088
23 January 2024 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7853034
29 October 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7822347
17 May 2023 Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7694980
25 August 2022 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7566708
6 April 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7431069
27 September 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7321652
31 July 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7274073
10 July 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7256974
9 July 2021 Damage Survey · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7251106
5 May 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7189098
12 August 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7063597
18 July 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7017378
4 October 2019 Damage Survey · Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6828584
10 April 2019 Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6660042
25 January 2019 Administrative Inspection · Deficiency Check · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6615191
2 August 2018 Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6499440
14 March 2018 Annual Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6372697
1 March 2017 Damage Survey · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6102047
18 January 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6072857
16 May 2016 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5861115
13 May 2015 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5144371
11 May 2015 Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5122880
13 September 2014 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4983730
11 August 2014 Damage Survey · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4952511
11 August 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4953121
10 May 2014 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4856523
9 May 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4856316
30 April 2014 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4846112
16 April 2014 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4837587
15 April 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4837300
14 August 2013 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4577380

Deficiency record · 26

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 October 2024 Resolved
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2024
Resolved 26 October 2024
Resolution: Technician evaluated steering system. System was reported as functioning as designed.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 25 June 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. There are multiple cracks in frame 15 on the number one end. Submit a plan proposal and implement approved plan to the satisfaction of the marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2024
Resolved 1 August 2024
Resolution: Rcvd report from welder stating adequate repairs were made.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 2 June 2024 Resolved
Any vessel of at least five net tons which engages in [...] coastwise trade (Defined as the transportation of passengers or merchandise between points embraced within the coastwise laws of the United States). Vessel had an expired Certificate of Documentation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2024
Resolved 9 July 2024
Resolution: Confirmed vessel has a valid COD.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 June 2024 Resolved
46 CFR 176.810(b); (b)(1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. (b)(2) The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel had no annual servicing performed on the portable extinguishers, and no documentation for fixed servicing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2024
Resolved 27 June 2024
Resolution: Confirmed maintenance completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 June 2024 Resolved
46 CFR 176.303(b); Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. Life buoy on car deck was severely sun damaged and worn, with outer covering peeling off inner foam core.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2024
Resolved 27 June 2024
Resolution: New buoy installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2024 Resolved
46 CFR 176.302; Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible, in a conspicuous place on the vessel where observation by passengers is likely.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2024
Resolved 1 August 2024
Resolution: Item posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2024 Resolved
46 CFR 176.306; When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2024
Resolved 1 August 2024
Resolution: Item posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2024 Resolved
Employers must maintain records of chemical tests as provided in 49 CFR 40.333 and must make these records available to Coast Guard officials upon request. Vessel had no current documentation to show enrollment and testing of crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2024
Resolved 1 August 2024
Resolution: Confirmed test results maintained.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 June 2024 Resolved
You must submit your written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection. Vessel allowed their COI to lapse with no notice to OCMI.
Action required: 10 - Deficiency Rectified
Resolved 27 June 2024
Resolution: COI was completed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 June 2024 Resolved
(1)(a) Each stowage container for life jackets must not be capable of being locked. (b) The stowage locations of the personal flotation devices carried in addition to life jackets under § 180.72, must be separate from the life jackets, and such as not to be easily confused with that of the life jackets. Vessel has life jackets stowed in a locked locker with work-vests. Vessel removed work-vests and was instructed to ensure locker is unlocked during operations. Key is located directly adjacent to locker.
Action required: 10 - Deficiency Rectified
Resolved 1 August 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 September 2021 Resolved
VESSEL REPORTED TRANSMISSION SHIFTING ISSUE WHILE VESSEL WAS AT TERMINAL IN KELLER, WA. TRANSMISSION UNABLE TO STAY ENGAGED IN ONE DIRECTION. MACHINERY AND EQUIPMENT INSTALLED ON EACH VESSEL MUST BE SUITABLE FOR THE VESSSEL AND ITS OPERATION AND FOR THE PURPOSE INTENDED. PRIOR TO DEPARTURE FROM TERMINAL, SUBMIT A TECH REPORT ATTESTING TO SATISFACTORY REPAIRS MADE. CITE: 46CFR182.100
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2021
Resolution: Received attestation from crew members that faulty transmission shifting solenoid was replaced with a new solenoid. Tests completed with no issues. ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2021 Resolved
Vessel had vibration on engine, followed by a code: injector mistiming. Vessel may not carry passengers until the engine is fixed.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2021
Resolved 13 October 2021
Resolution: Cleared previously via tech report.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 4 October 2019 Resolved
Make permanent repairs to both #1 and and #2 ends in way of all fractures. Submit repair proposal to the USCG for approval. Reduce cargo load to 1/2 authorized and provide a root cause analysis of the damage. Master use judgement to reduce stresses on the hull with consideration to high winds and seas in excess of 1 foot. 46 CFR 177
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 18 October 2019
Resolved 5 January 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 2 August 2018 Resolved
In the #1 end engine room behind the switchboard, approx 2" of butt weld found with discontinutity. Monitor weld to ensure it does not spread and leak. Submit repair proposal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 27 September 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 August 2018 Resolved
Replace gasket for aft engine room hatch (#2 end).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 29 August 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 2 August 2018 Resolved
Remove oil, debris, and water from eng room bilges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 29 August 2018
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 2 August 2018 Resolved
Remove and clean all debris and hydraulic oil in #1 and #2 ends steering gear spaces.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 29 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 August 2018 Resolved
In shaft alleys/void spaces remove metal shavings and sand from bilges to prevent blockage for bilge suction.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2018
Resolved 29 August 2018
Construction/Loadline › Hull › Hull Plating
Issued 14 March 2018 Resolved
Make temporary repairs to the hull fracture at frame 17 IAW 46 CFR 176.700.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 21 March 2018
Resolution: Divers from Global Dive installed temporary patch (Splash Zone) to the underwater portion of the hull fracture.
Construction/Loadline › Hull › Hull Plating
Issued 14 March 2018 Resolved
Make permanent repairs to the hull fracture at frame 17 46 CFR 176.700.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 14 April 2018
Resolved 13 April 2018
Resolution: Permanent repairs were made with a 12" x 9" insert.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 14 March 2018 Resolved
Re-install exhaust heat shielding for both main diesel engines 46 CFR 182.430(a).
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 21 March 2018
Resolution: Heat sheilding re-installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 March 2018 Resolved
Install the screw down post type battery in the float light 46 CFR 180.25(a).
Action required: 705 - Other - as specified
Due 22 March 2018
Resolved 21 March 2018
Resolution: Correct battery installed.
Construction/Loadline › Hull › Bottom Plating
Issued 13 September 2014 Resolved
Provide repair proposal and complete permanent repairs to bottom hull plating at frame 17 on port side #1 end as discussed.
Action required: 705 - Other - as specified
Due 14 October 2014
Resolved 5 October 2014
Resolution: Permanent repairs completed to hull.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 13 September 2014 Resolved
Crew must monitor void space on #1 end every four hours while in operation until permanent repairs are made to the hull plate.
Action required: 705 - Other - as specified
Due 14 October 2014
Resolved 5 October 2014
Resolution: Permanent repairs made to the hull.
Engineering › Steering Gear System › Chain
Issued 11 August 2014 Resolved
Feedback chain retention bolt failed. Replace with factory approverd equipment.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 18 May 2015
Resolution: Feedback chain arrangement replaced with factory equipment.
Engineering › Steering Gear System › Power Unit
Issued 10 May 2014 Resolved
Washington [name withheld] reported that the vessels steering system on the #1 helm/#2 steering end had the rudder move hard port without giving the command. Troubleshoot and make required repairs to make system fully operational.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2014
Resolution: Rolls-Royce representatives were unable to replicate problem. System is operating within normal parameters.

Casualty record · 6

15 April 2014Routine · role: Involved in a Marine Casualty · activity 4837300
12 August 2020Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7063597
10 July 2021Routine · role: Involved in a Marine Casualty · activity 7256974
25 August 2022Routine · role: Involved in a Marine Casualty · activity 7566708
14 October 2024Routine · role: Involved in a Marine Casualty · activity 8020826
22 November 2024Routine · role: Involved in a Marine Casualty · activity 8040304
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.