← All vessels
DISCOVER
DISCOVER is a 2012 passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2016, most recently in April 2024, along with 33 deficiencies.
Records from 2016 to 2024. Most recent: inspection, 14 April 2024.
- Built
- 2012
- Last inspected
- 14 April 2024
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 33 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1238677
WDG3273
1164781
Flag
UNITED STATES
Maury page id
psix-1164781
Inspections, by type
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)43.0 ft × 10.0 ft × 4.0 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNORTH RIVER BOATS INC · ROSEBURG, OR, UNITED STATES · built 2012
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portSKAGWAY, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
14 April 2024
Annual Inspection · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7865248
24 April 2023
Annual Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7673449
11 April 2022
Hull Examination · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7429032
23 September 2021
Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7318973
29 June 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6993011
19 April 2019
Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6666284
30 April 2018
Annual Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6411189
26 April 2017
Internal Structural Exam · Administrative Inspection · Hull Examination · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6128537
4 May 2016
Deficiency Check · Annual Inspection · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5869165
Deficiency record · 33
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 April 2024
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: (1) The pump is listed by an independent laboratory as meeting the requirements in UL 1113. On-board fwd and aft bilge pumps are not UL1113 listed.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 14 April 2024
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency... New crew members have not completed familiarization and drills. 46CFR185.420
***To be cleared by attending Marine Inspector***
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 April 2024
Resolved
In systems and applications where flexible hoses are permitted to be clamped:(1) Double hose clamping is required where practicable. Bilge flexible hoses have one clamp mounted at each end. 46CFR182.410(d)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 April 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Aft alarm is inoperable. 46CFR182.530(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must:(2) Be of at least 18.3 meters (60 feet) in length. Life line is less than 60'. 46CFR180.70(c)
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 April 2024
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Compass light on-board is not illuminated. Restricted to daytime operations. 46CFR184.402(c)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 April 2024
Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent
material, such that all pages are visible. All pages of the COI are not displayed. 46CFR176.302
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 April 2024
Resolved
For fixed-gas fire extinguishing systems...The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. O/O
could not provide servicing records for fixed gas
suppression system. 46CFR176.810(b)(2)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2024
Resolved
Each ring life buoy on a vessel must: (1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Top and bottom life buoy grab lines are deteriorating. 46CFR180.70(b)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 April 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. Onboard charts are not current. 46CFR184.420(a)(1)
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 April 2024
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Operator could not provide evidence of consortium enrollment. 46CFR 16.230(a)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2024
Resolved
The servicing facility must issue a certificate to the liferaft owner or owner's agent for each liferaft it services. Owner/operator did not have servicing certificate issued by the servicing facility. 46CFR160.151-57(p)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 April 2023
Resolved
Ring life buoys. A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required.
(1) Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110.
(2) Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy.
(3) Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy. Vessels float light is not working repair or replace float light. 46 CFR 180.70
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2023
Resolved
Life jacket placards.
(a) Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessels lifejacket donning placard did not match the style type 1 PFD's that are onboard. Update donning placard to match type 1 PFDs that are onboard. 46 CFR 185.516
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 April 2023
Resolved
Navigation lights.
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. 46 CFR 183.420
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 April 2023
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:
(1) A light to indicate discharge;
(2) An audible alarm that sounds upon discharge; and
(3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. The audible alarm for the fire boy discharge is not working repair or replace faulty alarm. 46 CFR 181.420
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 April 2022
Resolved
On a vessel of at least 26' in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each space with a thru hull fitting below the deepest load waterline, such as a lazerette. The forward void high water bilge alarm was not working. 46 CFR 182.530
Communications › Radio Communications › EPIRB
Issued 30 April 2018
Resolved
Replace EPIRB that has expired batteries.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 30 April 2018
Resolved
Provide proof of enrollment in a drug and alcohol testing program including a list of covered employees.
Lifesaving › Lifebuoys › Serviceable
Issued 30 April 2018
Resolved
Provide servicable lifebuoy.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 April 2018
Resolved
Repair audible alarm on bilge high level detector.
Navigation › Piloting/Steering › Marine Charts
Issued 26 April 2017
Resolved
Provide updated marine charts onboard the vessel. To the satisfaction of the attending Coast Guard Marine Inspector. To the satisfaction of the attending Coast Guard Marine Inspector.
Engineering › Bilge Water Management System › Interface Detector
Issued 26 April 2017
Resolved
Properly repair automatic function of electrical submersible bilge pumps. Has this feature however it was not working. To the satisfaction of the attending Coast Guard Marine. Inspector.
Engineering › Bilge Water Management System › Valve
Issued 4 May 2016
Resolved
Properly install a marine grade valve in the fwd void electrical submersible bilge overboard piping.
Accommodation/Occupational Safety › Ventilation › General
Issued 4 May 2016
Resolved
Install warning label to run the fuel tank void power blower prior to starting engines.
Fire Fighting › Means of Escape › Blocked
Issued 4 May 2016
Resolved
Properly label emerbency exits.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 4 May 2016
Resolved
Have onboard non expired alcohol test strips due to remote ops.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 May 2016
Resolved
Renew expired items in vessels first aid kit.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 4 May 2016
Resolved
Properly stencil vessel's name and hailing port onto the vessels stern.
Construction/Loadline › Structures › Door
Issued 4 May 2016
Resolved
Properly repair hairline cracks at the base of the cabin side doors. Aprox 2" - 3" inches in length. Monitor until repaired and notify the local OCMI if the condition worsens. Due by the vessels 2017 hull/ise exam.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 4 May 2016
Resolved
Properly repair the audible alarm located at the helm station on the vessels fire boy system. All other aspects of the system are functional/working properly.
Communications › Radio Communications › EPIRB
Issued 4 May 2016
Resolved
Properly renew vsl's expired EPIRB hydrostatic release.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 4 May 2016
Resolved
Vessels did not hold a valid FCC Marine Radio Operators Permit. Vessel restricted to 1000' fm shore.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.