MAURY USCG vessel records
← All vessels

DISCOVER

DISCOVER is a 2012 passenger vessel (inspected). The Coast Guard has recorded 9 inspections since 2016, most recently in April 2024, along with 33 deficiencies.

Records from 2016 to 2024. Most recent: inspection, 14 April 2024.

Built
2012
Last inspected
14 April 2024
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDG3273
1164781
Flag
UNITED STATES
Maury page id
psix-1164781

Inspections, by type

Years with a record 9 calendar years (2016–2024)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)43.0 ft × 10.0 ft × 4.0 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNORTH RIVER BOATS INC · ROSEBURG, OR, UNITED STATES · built 2012
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portSKAGWAY, AK
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 March 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Gross Ton
11 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 9

14 April 2024 Annual Inspection · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7865248
24 April 2023 Annual Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7673449
11 April 2022 Hull Examination · Internal Structural Exam · COI Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7429032
23 September 2021 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7318973
29 June 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6993011
19 April 2019 Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6666284
30 April 2018 Annual Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6411189
26 April 2017 Internal Structural Exam · Administrative Inspection · Hull Examination · COI Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6128537
4 May 2016 Deficiency Check · Annual Inspection · Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5869165

Deficiency record · 33

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 April 2024 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: (1) The pump is listed by an independent laboratory as meeting the requirements in UL 1113. On-board fwd and aft bilge pumps are not UL1113 listed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2024
Resolution: UL Bilge pumps installed; all sat.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 14 April 2024 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency... New crew members have not completed familiarization and drills. 46CFR185.420 ***To be cleared by attending Marine Inspector***
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2024
Resolution: Attended and verified crew familiarization.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 April 2024 Resolved
In systems and applications where flexible hoses are permitted to be clamped:(1) Double hose clamping is required where practicable. Bilge flexible hoses have one clamp mounted at each end. 46CFR182.410(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2024
Resolution: Double clamps installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 April 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Aft alarm is inoperable. 46CFR182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2024
Resolution: Operable; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2024 Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must:(2) Be of at least 18.3 meters (60 feet) in length. Life line is less than 60'. 46CFR180.70(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2024
Resolution: Picture of 60' line provided.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 14 April 2024 Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Compass light on-board is not illuminated. Restricted to daytime operations. 46CFR184.402(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2024
Resolution: All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 14 April 2024 Resolved
The Certificate of Inspection and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible. All pages of the COI are not displayed. 46CFR176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2024
Resolution: Displayed; all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 April 2024 Resolved
For fixed-gas fire extinguishing systems...The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. O/O could not provide servicing records for fixed gas suppression system. 46CFR176.810(b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2024
Resolution: Provided; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2024 Resolved
Each ring life buoy on a vessel must: (1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Top and bottom life buoy grab lines are deteriorating. 46CFR180.70(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2024
Resolution: New life buoy provided and mounted on vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 April 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible. Onboard charts are not current. 46CFR184.420(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2024
Resolution: New Charts provided.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 April 2024 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Operator could not provide evidence of consortium enrollment. 46CFR 16.230(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 May 2024
Resolution: Verified consortium enrollment.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2024 Resolved
The servicing facility must issue a certificate to the liferaft owner or owner's agent for each liferaft it services. Owner/operator did not have servicing certificate issued by the servicing facility. 46CFR160.151-57(p)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 May 2024
Resolution: Servicing cert provided; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 April 2023 Resolved
Ring life buoys. A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. (1) Each floating waterlight must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. (2) Each ring life buoy with a floating waterlight must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the waterlight around the body of the ring life buoy. (3) Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy. Vessels float light is not working repair or replace float light. 46 CFR 180.70
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2023
Resolution: Operator replaced the battery with an approved battery and tested - all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2023 Resolved
Life jacket placards. (a) Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessels lifejacket donning placard did not match the style type 1 PFD's that are onboard. Update donning placard to match type 1 PFDs that are onboard. 46 CFR 185.516
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2023
Resolution: Operator updated donning placard to match onboard PFDs - all sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 April 2023 Resolved
Navigation lights. All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant. 46 CFR 183.420
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2023
Resolution: Operator replaced faulty light bulb and tested - all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 April 2023 Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station: (1) A light to indicate discharge; (2) An audible alarm that sounds upon discharge; and (3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. The audible alarm for the fire boy discharge is not working repair or replace faulty alarm. 46 CFR 181.420
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2023
Resolution: Operator replaced faulty alarm at the operating station and tested - all sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 April 2022 Resolved
On a vessel of at least 26' in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each space with a thru hull fitting below the deepest load waterline, such as a lazerette. The forward void high water bilge alarm was not working. 46 CFR 182.530
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2022
Resolved 19 April 2022
Resolution: Owner replaced a faulty float switch tested - all sat.
Communications › Radio Communications › EPIRB
Issued 30 April 2018 Resolved
Replace EPIRB that has expired batteries.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2018
Resolution: Received photos of new EPIRB installed.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 30 April 2018 Resolved
Provide proof of enrollment in a drug and alcohol testing program including a list of covered employees.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2018
Resolved 9 May 2018
Resolution: Received proof of enrollment.
Lifesaving › Lifebuoys › Serviceable
Issued 30 April 2018 Resolved
Provide servicable lifebuoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2018
Resolved 9 May 2018
Resolution: New lifebuoy provided.
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 April 2018 Resolved
Repair audible alarm on bilge high level detector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2018
Resolved 9 May 2018
Resolution: Alarm restored.
Navigation › Piloting/Steering › Marine Charts
Issued 26 April 2017 Resolved
Provide updated marine charts onboard the vessel. To the satisfaction of the attending Coast Guard Marine Inspector. To the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 10 May 2017
Resolution: Attended vessel on pier in Skagway, verified presence of up to date charts.
Engineering › Bilge Water Management System › Interface Detector
Issued 26 April 2017 Resolved
Properly repair automatic function of electrical submersible bilge pumps. Has this feature however it was not working. To the satisfaction of the attending Coast Guard Marine. Inspector.
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 26 April 2017
Resolution: Owners rep replaced faulty float switches. Tested SAT.
Engineering › Bilge Water Management System › Valve
Issued 4 May 2016 Resolved
Properly install a marine grade valve in the fwd void electrical submersible bilge overboard piping.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 7 May 2016
Accommodation/Occupational Safety › Ventilation › General
Issued 4 May 2016 Resolved
Install warning label to run the fuel tank void power blower prior to starting engines.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 7 May 2016
Fire Fighting › Means of Escape › Blocked
Issued 4 May 2016 Resolved
Properly label emerbency exits.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 7 May 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 4 May 2016 Resolved
Have onboard non expired alcohol test strips due to remote ops.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 4 May 2016
Resolution: Owner obtained two alcohol test strips and placed them onboard the vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 4 May 2016 Resolved
Renew expired items in vessels first aid kit.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 7 May 2016
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 4 May 2016 Resolved
Properly stencil vessel's name and hailing port onto the vessels stern.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 7 May 2016
Construction/Loadline › Structures › Door
Issued 4 May 2016 Resolved
Properly repair hairline cracks at the base of the cabin side doors. Aprox 2" - 3" inches in length. Monitor until repaired and notify the local OCMI if the condition worsens. Due by the vessels 2017 hull/ise exam.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 26 April 2017
Resolution: Professional welder drill stopped, gouged and re-welded cracks - visual inspection SAT.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 4 May 2016 Resolved
Properly repair the audible alarm located at the helm station on the vessels fire boy system. All other aspects of the system are functional/working properly.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 7 May 2016
Communications › Radio Communications › EPIRB
Issued 4 May 2016 Resolved
Properly renew vsl's expired EPIRB hydrostatic release.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2016
Resolved 4 May 2016
Resolution: Vessels crew renewed the expired hydro static release with a new one.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 4 May 2016 Resolved
Vessels did not hold a valid FCC Marine Radio Operators Permit. Vessel restricted to 1000' fm shore.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 4 May 2016
Resolution: Vessels master obtained a valid FCC Marine Radio Operators Permit.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.