MAURY USCG vessel records
← All vessels

TORM ARAWA

TORM ARAWA is a tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in January 2026, along with 5 deficiencies and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 18 January 2026.

Built
Not recorded
Last inspected
18 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9543548
1164804
Flag
DENMARK
Maury page id
psix-1164804

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded4
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it30302 - Convention (Subpart B), Gross Ton
14562 - Convention (Subpart B), Net Ton
44999 - Dead Weight, Metric Ton
56877 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 13

18 January 2026 COC-CHEM & TVE Renew · Deficiency Check · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8293692
2 March 2024 Administrative Inspection · COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7873078
27 February 2023 PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7642564
17 January 2021 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7126054
28 August 2020 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7037176
17 August 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7035403
10 June 2019 Ballast Water Examination · ISPS II Exam · COC-CHEM Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6706879
28 October 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6296603
22 October 2017 ISPS II Exam · COE-Offshore · Ballast Water Examination · COC-CHEM & TVE Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6292580
21 October 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6292346
19 October 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6290826
19 October 2017 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6290841
13 May 2016 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 5873378

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 January 2026 Resolved
In addition to complying with specific provisions for fire integrity of bulkheads of tankers, the minimum fire integrity shall be as prescribed in tables 9.7 and 9.8. An atmospheric sampling point penetrated the steel bulkhead separating the boiler space and IGG space; the bulkhead is therefore not in compliance with Table 9.7 in SOLAS II-2/9 for proper fire protection. SOLAS 74(20) II-2/9.2.4.2.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2026
Resolved 30 January 2026
Resolution: Received satisfactory documentation of rectified cable penetration into bulkhead
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for personnel on tankers
Issued 27 February 2023 Resolved
All seafarers serving on board who are required to be certificated in accordance with the Convention hold an appropriate certificate or a valid dispensation, or provide documentary proof that an application for and endorsement has been submitted to the administration in accordance with regulation I/10, paragraph 5. PSCO observed Denmark flag state endorsement for master license was indicated as not valid for service on tankers. Previous Denmark flag state endorsement indicated master was certified for tankers. 74 SOLAS(20) V 14.2.1 STCW I/4.1.1
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 February 2023
Resolution: Flag submitted satisfactory documentation attesting to Masters authority to serve on tank vessels.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 28 August 2020 Resolved
Where main or auxiliary machinery including pressure vessels or any parts of such machinery are subject to internal pressure and may be subject to dangerous overpressure, means shall be provided where practicable to protect against such excessive pressure. PSCO observed wire wrapped around safety valve handle of aux air receiver within the vicinity of start air compressors. Crew stated this was added because excessive vibration was causing unintended activation of the safety valve. Wire was removed and no unintended release happened.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 August 2020
Resolved 28 August 2020
Resolution: Removed the wire from the valve and created a defect job report.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 28 August 2020 Resolved
The company should ensure that any non-conformity is reported, with its possible cause, if known. PSCO observed auxiliary air receiver relief valve was wire tied to prevent the release of compressed air. Last internal inspection from SMS was 12 March 2020. There were no defect job reports made for this instance as required in ships procedures.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 August 2020
Resolved 28 August 2020
Resolution: Removed the wire from the valve and created a defect job report.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2019 Resolved
Cite: 74SOLAS(14)II/20.2 / Code: 11118 / Action: 40ac before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO discovered that approximately 50 percent of the lifejackets on board the ship and internal buoyant material visibly showing due to the type of light that was inserted into the lifejacket.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 August 2020
Resolution: Vessel provided pictures and class correspondence that 50% of lifejackets have been renewed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.