Records from 2016 to 2026. Most recent: inspection, 12 May 2026.
Inspection history · 18
12 May 2026
Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8350043
18 March 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8095923
27 November 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8042801
14 May 2024
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7911550
23 May 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7696655
9 November 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7592355
30 March 2022
Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7416808
17 June 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7226095
16 November 2020
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7096046
29 March 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6932848
2 December 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6865474
16 May 2019
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6686751
19 November 2018
Internal Structural Exam · Drydock Exam · Plan Review "T" Boat
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6583705
20 June 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6450895
10 April 2017
COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6119434
16 December 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6058028
2 June 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5894511
14 January 2016
Inclining Experiment
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5805228
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2026
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. MI observed faded lettering on the vessel's 02 ring buouy(s). O/o must re-mark the ring buoys.
46 CFR 185.604 (b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2026
Resolved 15 May 2026
Resolution: Ring lifebuoy stenciled with new lettering.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 May 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Marine inspector observed two expired burn gel and aspirin packages.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2024
Resolved 24 May 2024
Resolution: Vessel representative provided adequate photographs attesting to the replacement of burn gel and aspirin. Items are no longer expired. Deficency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 May 2023
Resolved
Each life float must meet the requirements in subpart 160.010 of this chapter for a peripheral body type buoyant apparatus designed so that persons supported are only partially immersed. Materials not covered in this subpart must be of good quality and suitable for the purpose intended.
Cracks were found on the external protective covering of the vessel's 02 life floats, exposing the inner material of the life float.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 1 June 2023
Resolution: Vessel representative emailed photograph of repaired life floats. Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2023
Resolved
A life preserver must be of such construction, material, and workmanship that it can perform its intended function in all weathers and at all temperatures which may be expected in the normal usage of the life preserver.
02 of the vessel's life preservers had signs of deterioration at the edges of the external protective covering, affecting the preservers effectiveness during normal usage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 June 2023
Resolved 1 June 2023
Resolution: Vessel representative emailed photograph of new life jackets. Deficiency cleared.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical first aid
Issued 30 March 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 31 March 2022
Resolution: Received photographic evidence.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 March 2022
Resolved
Replace Ring [name withheld] indicated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 10 May 2022
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 30 March 2022
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 10 May 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 March 2022
Resolved
A hatch cover must: (1) Have securing devices; and (2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 10 May 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 March 2022
Resolved
The forward bow seating area indicates that PFD are being stored there. The PFDs indicated have been moved inside the cabin to prevent deterioration. Remove labeling if the PFDs will no longer be stored here.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 10 May 2022
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2019
Resolved
Provide at least three 2.5 gal buckets with attached lanyard. The words fire bucket must be stenciled in a contrasting color on each bucket. 46CFR181.610
Vessel only had 2
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2019
Resolved 22 May 2019
Resolution: Sent pictures confirming def rectified
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 May 2019
Resolved
Remote fuel shut-off stations must be marked in clearly legible letters at least 1" high indicating purpose of the valve and direction of operation. 46CFR185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2019
Resolved 22 May 2019
Resolution: Sent pictures confirming def rectified
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2019
Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery is passed. 46CFR185.726(d)
Batter Expired
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2019
Resolved 22 May 2019
Resolution: Sent pictures confirming def rectified
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 June 2018
Resolved
Fire protection equipment shall be ready for inspection, including all smoke and fire protection systems. Cabin smoke detector was inoperable due to lack of power source. Battery was installed during inspection and proper operation confirmed.
Action required: 10 - Deficiency Rectified
Due 3 July 2018
Resolved 3 July 2018
Resolution: Battery was installed during inspection and proper operation confirmed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 June 2018
Resolved
Vessel must carry a first aid kit under approval series 160.041. First aid kit did not contain required contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2018
Resolved 17 July 2018
Resolution: Approved first aid kit purchased and stored on vessel. Photo documentation attached.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 20 June 2018
Resolved
Vessel must carry 1 10-B:C fire extinguisher at operating station. Extinguisher was not present on vessel and not permanently mounted using appropriate bracket at the operating station. Rectify deficiency w/in 7 days.
Action required: 705 - Other - as specified
Due 10 July 2018
Resolved 10 July 2018
Resolution: Fire extinguisher mounted in vicinity of topside operating station. Photo documentation attached.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 20 June 2018
Resolved
Vessel must carry adequate and up-to-date U.S. Coast Pilot. Vessel had only U.S. Coast Pilot 2016 Edition on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2018
Resolved 17 July 2018
Resolution: 2018 edition of Coast Pilot printed and stored on vessel. Photo documentation attached.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 June 2018
Resolved
Vessel shall be provided with a whistle. Vessel's whistle was inoperable and disposable sound signaling device was being used temporarily.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2018
Resolved 17 July 2018
Resolution: New electronic sound signalling device purchased and installed. Photo documentation attached.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 June 2018
Resolved
Fuel lines of flexible hose must be installed with 2 clamps at both ends of the hose. Only one hose clamp was present on tank side end of both fuel lines. Second clamp was installed to both fuel lines.
Action required: 10 - Deficiency Rectified
Due 3 July 2018
Resolved 3 July 2018
Resolution: Second clamp was installed to fuel line intakes from both starboard and port side tanks. Photo documentation attached.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 2 June 2016
Resolved
Replace expired batteries on ring life buoys. 46 CFR 180.70(d).1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 3 June 2016
Resolution: Batteries have been replaced with proper approved batteries.
Lifesaving › Hand Flares › Not on Board
Issued 2 June 2016
Resolved
Vessel had four (4) red flare distress signals onboard. Provide two (2) additional red flare distress signals or two hand orange smoke distress signals. 46 CFR 180.68(b).1
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 3 June 2016
Resolution: New flares have been procured and kept onboard.
Lifesaving › Lifefloat › Paddle
Issued 2 June 2016
Resolved
Provide two (2) additional buoyant paddles of at least four (4) feet in length for life float. 46 CFR 180.150 (d)
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 3 June 2016
Resolution: Two new paddles have been acquired and are kept onboard with the lifefloats.
Engineering › Bilge Water Management System › Interface Detector
Issued 2 June 2016
Resolved
Visual indicator for the high bilge level alarm in the STBD bilge was inoperable. Audible alarm was fully operational. Repair visual indicator for the high bilge level alarm for STBD bilge. 46 CFR 182.530(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 3 June 2016
Resolution: Indicator light was replaced and observed to be functioning correctly.