MAURY USCG vessel records
← All vessels

MAERSK KATALIN

MAERSK KATALIN is a 2012 tank ship. The Coast Guard has recorded 10 inspections since 2016, most recently in April 2023, along with 1 deficiency and 2 operational controls.

Records from 2016 to 2023. Most recent: inspection, 28 April 2023.

Built
2012
Last inspected
28 April 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9431317
9V8528
1165152
Flag
SINGAPORE
Maury page id
psix-1165152

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded3
Years with a record 5 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it24463 - Convention (Subpart B), Gross Ton
11668 - Convention (Subpart B), Net Ton
39708 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 10

28 April 2023 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7677187
10 March 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7153867
23 February 2021 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7142468
23 February 2021 PSC B · COC-CHEM & TVE Renew
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 7143047
28 June 2019 Ballast Water Examination · COC-CHEM & TVE Annual · ISPS II Exam · COE-Dockside
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6723655
28 June 2019 Bulk Liquid Transfer Monitor
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6728779
14 May 2018 Ballast Water Examination · COC-CHEM & TVE Renew · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6413774
13 May 2018 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 6412182
11 May 2018 COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6412189
17 July 2016 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5946797

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 23 February 2021 Resolved
Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. PSCO observed the vessel's water mist fire fighting system had the outlet valves supplying water to the #2 and #3 generators in the closed position which would prevent the supply of water to these points in the case of a fire. 74SOLAS, II-2, 14.1.1
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 23 February 2021
Resolved 23 February 2021
Resolution: [name withheld] opened valves placing the system back into the ready position.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.