Records from 2016 to 2024. Most recent: inspection, 15 December 2024.
Inspection history · 9
15 December 2024
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8047649
14 December 2024
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8047388
2 February 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7134805
20 March 2020
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6929588
21 February 2020
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6913104
18 October 2019
MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6835007
25 October 2018
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6567838
13 October 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6555055
17 February 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5816771
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 14 December 2024
Resolved
THE PURPOSE OF THIS REGULATION IS TO PREVENT THE IGNITION OF COMBUSTIBLE MATERIALS OR FLAMMABLE LIQUIDS. FOR THIS PURPOSE, THE FOLLOWING FUNCTIONAL REQUIREMENTS SHALL BE MET: MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS.
PSCO OBSERVED POOLED OIL UNDER NO.3 GENERATOR.
CITE: 74 SOLAS (09) II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 January 2025
Resolved 15 December 2024
Resolution: VESSEL PROVIDED DOCUMENTATION WITH DEF CORRECTIONS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 October 2018
Resolved
1430 - Auxilliary engine - Each emergency generating set arranged to be automatically stareted shall be equipped with starting devices approved by the Administration. A second source of energy shall be demonstrated. The second means of starting the emergency generator is not functioning. 74SOLAS(04) Ch.II-1/Reg. 44.2
Action required: 15 - Rectify deficiencies by next port
Due 24 October 2018
Resolved 25 October 2018
Resolution: Code 17 changed to due date 24OCT18 to coincide with outstanding condition of class. PSC Attended vessel in New York and verified vessel had two means of starting the emergency generator and both were fully functional.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 18 February 2016
Resolved
74SOLAS(14) II-2/9.3.1: Where "A" class division are penetrated, such penetrations shall be tested in accordance with the Fire Test Procedures Code. Such penetrations shall be suitably insulated by extension of the insulation at the same level of the division. Vessel has improper penetration of forward bulkhead in steering gear room. 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 10 March 2016
Resolved 10 March 2016
Resolution: Received email confirmation of corrected penetrations
Fire Fighting › Miscellaneous Items › Materials for Overboard Outlets
Issued 18 February 2016
Resolved
74SOLAS(14) II-2/10.2.3.1.1: Each hose shall be provided with a nozzle and the necessary couplings. Hoses specified in this chapter as "fire hoses" shall, tegether with any necessary fittings and tools, be kept ready for use in conspicuous positions near water service hydrants or connections. Spanner wrenches were not present in numerous locations throughout the vessel. Corrected on the spot. 10c
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Corrected on the spot. Vessel had extra spanner wrenches that were immediately placed in service.
Deck/Cargo › Mooring/Anchoring › Mooring Arrangement
Issued 18 February 2016
Resolved
The regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following requirements shall be met: Means shall be provided to control leaks of flammable liquids. Vessel's hydraulic pump for the mooring system was found leaking fluid. Corrected on the spot. 10c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2016
Resolved 18 February 2016
Resolution: Cleaned up fluid on the deck and tightened the loose bolt.