DORSET is a 2011 tank ship. The Coast Guard has recorded 10 inspections since 2016, most recently in May 2026, along with 1 deficiency and 3 operational controls.
Records from 2016 to 2026. Most recent: operational control imposed, 2 June 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it45812 - Convention (Subpart B), Gross Ton 45812 - Regulatory (Subpart C or D), Gross Ton 13744 - Convention (Subpart B), Net Ton 13744 - Regulatory (Subpart C or D), Net Ton 53076 - Dead Weight, Ton 71198 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
28 May 2026Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8382505
30 November 2025Administrative Inspection · COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8273362
29 November 2024COC-GAS Renew · PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8041145
16 November 2023PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7818090
18 June 2023Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7717845
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 November 2024Resolved
The following fir eprotection systems shall be kept in good order so as to ensure thier required performance if a fire occurs: fire detection and fire alarm systems. Two heat detectors failed during testing, one in FOP flats and the other above the incinerator. Crew changed detectors and retested all satisfactory.
74 SOLAS (20) II-2/14.2.1.1.2
Action required: 10 - Deficiency Rectified
Resolved 29 November 2024
Resolution: Crew changed detectors and retested all satisfactory.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National