AAL MARS is a 2011 freight ship. The Coast Guard has recorded 6 inspections since 2017, most recently in March 2022, along with 3 deficiencies.

Records from 2017 to 2022. Most recent: inspection, 7 March 2022.

Built
2011
Last inspected
7 March 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 March 2022
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2017–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9509712
1166071
Flag
LIBERIA
Maury page id
psix-1166071

Documentation record

Tonnage as PSIX records it22863 - Convention (Subpart B), Gross Ton
10602 - Convention (Subpart B), Net Ton
33271 - Dead Weight, Ton
43436 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

7 March 2022 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7402407
28 February 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7403207
16 March 2020 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6923360
7 May 2018 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6405779
9 April 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6120540
7 April 2017 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6114264

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 March 2020 Resolved
Connections within the fuel supply and spill lines of a diesel engine fuel system shall be constructed having regard to their ability to prevent pressurized oil fuel leaks while in service and after maintenance. PSCO observed a continuous dishcarge of diesel from the number six cylinder head on the number one generator. 74 SOLAS (14) II-2/4.2.2.5.4
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 March 2020
Resolution: Received satisfactory class report stating that repairs had been made to the number one generator and that it was functioning properly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 March 2020 Resolved
Fire Protection sytems shall be maintained ready for use. PSCO observed smoke detectors in the welding shop and lower engine room to have a plastic cover over it wrapped with tape rendering it inoperable. 74 SOLAS (14) II-2/14.1.1
Action required: 10 - Deficiency Rectified
Due 16 March 2020
Resolved 16 March 2020
Resolution: PSCO observed crew member remove plastic covers from smoke detectors and conduct satisfactory tests of smoke detectors.
Lifesaving › Lifebuoys › Size
Issued 7 May 2018 Resolved
Self-activating smoke signals required by regulation III/ 7.1.3 shall be connected to a life buoy having a mass of not less than 4 kg.74 Solas(14) III/7.1 LSA Code 2.1.1.7 50c
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2018
Resolved 10 May 2018
Resolution: Vessel received their shipment of a 4 kg lifebuoy. Sent pictures and receipt.

Ownership record