MAURY USCG vessel records
← All vessels

PAIWAN WISDOM

PAIWAN WISDOM is a 2010 freight ship. The Coast Guard has recorded 6 inspections since 2016, most recently in July 2026, along with 5 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 31 July 2026.

Built
2010
Last inspected
31 July 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9427122
1166073
Flag
PANAMA
Maury page id
psix-1166073

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 5 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it19825 - Convention (Subpart B), Gross Ton
10514 - Convention (Subpart B), Net Ton
7583 - Displacement, Metric Ton
31967 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 6

31 July 2026 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8451224
23 April 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8117783
23 April 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8117943
15 October 2021 PSC B
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7320210
2 March 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6095296
1 February 2016 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5807224

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 October 2021 Resolved
07109 - FIXED FIRE EXTINGUISHING INSTALLATION - CARGO SPACES ON CARGO SHIPS OF 2000 GT AND UPWARDS SHALL BE PROTECTED BY A FIXED CARBON DIOXIDE... FIRE EXTINGUISHING SYSTEM COMPLYING WITH THE... FSS CODE. THE PIPING FOR THE DISTRIBUITION OF FIRE EXTINGUISHING MEDIUM SHALL BE ARRANGED... AND SO POSITIONED THAT A UNIFORM DISTRIBUTION OF THE FIRE EXTINGUISHING MEDIUM IS OBTAINED. PSCO IDENTIFIED HOLED CO2 PIPING ON AFT PORT SIDE OF #2 CARGO HOLD, PREVENTING UNIFORM DISTRIBUITION OF CARBON DIOXIDE. 74SOLAS(09)II-2/10.7.1.3 FSS CODE 5.2.1.2.1 17AC
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 15 October 2021
Resolved 20 October 2021
Resolution: Received, reviewed and accepted class report from DNV stating the deficiency was rectified. Crew removed section of piping and welded in new pipe, as verified by class surveyor.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 15 October 2021 Resolved
07117 - JACKETED HIGH PRESSURE LINES AND OIL LEAKAGE ALARM - EXTERNAL HIGH PRESSURE FUEL DELIVERY LINES BETWEEN THE HIGH PRESSURE FUEL PUMPS AND FUEL INJECTORS SHALL BE PROTECTED WITH A JACKETED PIPING SYSTEM CAPABLE OF CONTAINING FUEL FROM A HIGH PRESSURE LINE FAILURE. PSCO OBSERVED MODIFIED JACKETING ON MDE NO.2 CYLINDER HIGH PRESSSURE FUEL LINE. 74SOLAS(09)II-2/4.2.2.5.2 - 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 20 October 2021
Resolution: Received, reviewed and accepted class report from DNV stating the deficiency was rectified. Proper insulation was installed on the MDE No. 2 cylinder high pressure fuel line.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 15 October 2021 Resolved
14199 - OTHER - AFTER ANY SURVEY OF THIS SHIP.. NO CHANGE SHALL BE MADE IN THE STRUCTURE, EQUIPMENT, SYSTEMS, FITTINGS, ARRANGEMENTS OR MATERIAL... WITHOUT THE SANCTION OF THE ADMINISTRATION. PSCO OBSERVED MODIFIED BILGE SEPARATOR NAME PLATE WITH EQUIPMENT SPECS. PERMANENTLY REMOVED. MARPOL I/6.4.2 - 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2021
Resolved 20 October 2021
Resolution: Received, reviewed and accepted class report from DNV stating the deficiency was rectified. Class surveyor verified name plate was legible and accurate.
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 15 October 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Resolved 28 October 2021
Resolution: Crew removed modified hose.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 1 February 2016 Resolved
74SOLAS (2014 CONS) CH II-2 REG 10.1.1 FSS CH 3.2.1.1.1 17ac Fire fighter's outfit shall comply with the Fire Safety Systems Code. Personal equipment shall consist of the following: protective clothing of material to protect the skin from heat radiating from the fire and from burns and scalding by steam. The outer surface shall be water-resistant. SEE NARRATIVE FOR ADDITIONAL INFORMATION
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2016
Resolution: VESSEL RECIEVED NEW FIREFIGHTING OUTFITS.

Ownership record