15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 11 April 2025
Resolved
The company and the ship shall comply with the requirements of the International Safty Code ... The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. Due to the presence of multiple deficiencies in different aspects of the exam an internal audit is required.
SOLAS(20) IX/3
ISM Code 10.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2025
Resolved 23 April 2025
Resolution: Ship conducted an internal audit. See documents tab.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 11 April 2025
Resolved
Satisfactory means in the form of guard rails shall be provided for the protection of the crew in getting to and from the machinery space conducting necessary work of the ship. On the second deck of the engine room, it was discovered that a guard rail was missing. After further investigation, it was revealed that the rail had been missing for one month.
ILLC 25.4
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 11 April 2025
Resolution: Crew installed new bar and installed it so that it can not be removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 April 2025
Resolved
The arrangements for the storage, distribution and utilization of oil used in pressure lubrication systems shall be such to ensure the safety of the ship and persons on board. There were approximately 20 barrels of hydraulic oil 08 feet away from the ship's welding and grinding table while grinding was occuring without the use of a curtain to block sparks.
SOLAS (20) II-2/4.2.3.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 April 2025
Resolution: Operation was stopped and the crew member was instructed to utilize the curtain and window blocker to block any further sparks.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 11 April 2025
Resolved
Hoses in this Chapter as "fire hoses" shall. together with any necessary fittings and tools, be kept ready for use in conspicuous spaces near the water service hydrants or connections. The ship's fire hose stations in the engine room did not have spanner wrenches included with them. The wrenches were kept in the workshops away from the hydrants.
SOLAS(20) II-2/10.2.5.1.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 11 April 2025
Resolution: After spanner wrenches were found, all fire stations were fitted with spanner wrenches.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 March 2020
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the EPA under 40CFR140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage. Vessel was discharging (pumping) their sewage from the approved MSD to a the 5TSP void space. Their sewage diagram has a hand written note authorizing said transfer. Required vessel to either provide documentation from class allowing the transfer of sewage or to clean the 5TSP voild space of sewage.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 18 March 2021
Resolved 3 April 2020
Resolution: See report.