Records from 2016 to 2025. Most recent: inspection, 9 April 2025.
Documentation record
Registered dimensions (L × B × D)277.9 ft × 60.0 ft × 24.0 ft
Registered tonnagegross 3,242 / net 1,420
ITC dimensions (L × B × D)277.9 ft × 60.0 ft × 24.0 ft
ITC tonnagegross 3,242 / net 1,420
BuilderGULF SHIP LLC · GULFPORT, MS, UNITED STATES · built 2013
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 December 2025 · expires 31 January 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7575 - Displacement, Gross Ton
4995 - Dead Weight, Gross Ton
3242 - Convention (Subpart B), Gross Ton
1420 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
9 April 2025
Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8109085
21 October 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8022243
7 May 2024
MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7884071
14 August 2023
ISM Oversight · ISM SMC Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7768200
10 May 2023
MTSA/ISPS Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7689517
8 May 2023
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7683548
14 September 2022
MTSA/ISPS Verification · ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7528346
17 June 2021
ACP Annual Oversight · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7228057
15 July 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7006806
27 August 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6796544
29 June 2018
Administrative Inspection · ACP COI Oversight · MTSA/ISPS Verification · Re-Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6455032
29 May 2018
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6435149
23 June 2017
Annual Inspection · Administrative Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6184198
8 August 2016
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5970415
5 May 2016
Administrative Inspection · ACP Periodic Oversight · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5870079
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 21 October 2024
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of design and construction adequate for the service for which they are intended.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 21 October 2024
Resolved 28 October 2024
Resolution: MV provided tech report to the satisfaction of the DMI. All sat. Documents are attached to MISLE.
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 14 September 2022
Resolved
AIS shall provide automatically to appropriately equipped shore stations, other ships and aircraft information, including the ships identity, type, position, course, speed, navigational status and other safety related info. AIS history (100+ days) showed ships Flag as Sweden. 74solas2020 V/19.2.4.5.1
Action required: 10 - Deficiency Rectified
Resolved 14 September 2022
Resolution: AIS information was changed to reflect current Flag.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 14 September 2022
Resolved
Means of control shall be provided for opening and closure of skylights, closure of openings in funnels which normally allows exhaust ventilation and closure of ventilator dampeners. Observed stack dampers not closing as designed. 74solas2020 II-2/5.2.2.1
Action required: 10 - Deficiency Rectified
Resolved 14 September 2022
Resolution: Vessels engineering department conducted maintenance and was able to satisfactory test dampers.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 17 June 2021
Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring reliability of such appliances. Rescue boat davit was found not greased as per manufacturers recommendations. Furthermore, all grease button fittings were found painted over. Crew removed paint and greased accordingly.
Action required: 10 - Deficiency Rectified
Due 22 July 2021
Resolved 22 July 2021
Resolution: Def rectified prior to departing vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 17 June 2021
Resolved
Instructions for on-board maintenance of life-saving appliances shall be easily understood, illustrated wherever possible, and as appropriate, shall include the following for each appliance: .4 Diagram of lubrication points with the recommended lubricants. Rescue Boat Davit grease fitting diagram was not posted nor made available for crew to perform maintenance. Provide diagram and attach to maintenance checklist for crew reference.
Action required: 10 - Deficiency Rectified
Due 22 July 2021
Resolved 22 July 2021
Resolution: Def rectified prior to departing vessel.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 June 2021
Resolved
Emergency generator. A second source of energy shall be provided for an additional three starts. Batteries were unable to start generator nor able to hold a charge. Crew replaced batteries and corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 22 July 2021
Resolved 22 July 2021
Resolution: Def rectified prior to departing vessel.
Lifesaving › Launching Appliances › Davit
Issued 23 June 2017
Resolved
SHOW PROPER OPERATION OF RESCUE BOAT DAVIT TO ATTENDING ABS SURVEYOR.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2017
Resolved 23 June 2017
Resolution: ABS witnessed proper operation