← All vessels
RIGEL LEADER
RIGEL LEADER is a 2012 freight ship. The Coast Guard has recorded 14 inspections since 2014, most recently in March 2026, along with 13 deficiencies and 1 operational control.
Records from 2014 to 2026. Most recent: inspection, 18 March 2026.
- Built
- 2012
- Last inspected
- 18 March 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9604940 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
7KLE
1167477
Flag
JAPAN
—
Maury page id
psix-1167477
Inspections, by type
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it59337 - Convention (Subpart B), Gross Ton
18884 - Dead Weight, Metric Ton
34730 - Displacement, Metric Ton
19077 - Convention (Subpart B), Net Ton
18884 - Dead Weight, Metric Ton
34730 - Displacement, Metric Ton
19077 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 14
18 March 2026
PSC B
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8325169
31 July 2024
PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7971110
17 December 2023
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7838419
26 April 2023
Appeal
Administrative · Commandant (CG-CVC) · Activity 7675907
23 April 2023
Deficiency Check · PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7669082
7 March 2023
PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7646715
28 February 2023
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7639367
18 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7510017
15 July 2021
PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7256911
17 December 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6873043
26 January 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6340957
28 October 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6031125
22 July 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5187169
23 May 2014
PII Safety Exam · ISPS II Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4866259
Deficiency record · 13
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 18 March 2026
Resolved
The company should establish procedures to ensure the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements. The company should ensure that records of these activities are maintained. PSCOs found 05 PFDs in aft locker with expired lights. No maintenance records matching the condition of the PFDs was available.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 March 2026
Resolved
PSCOs found 05 PFD lights expired in aft storage locker at the portable liferaft station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 18 March 2026
Resolved
All lifeboat rations were expired.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 March 2026
Resolved
PSCO found no logbook entries that could be correlated with the condition and disposition of the PFDs found in the aft storage locker.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 7 March 2023
Resolved
DOORS REQUIRED TO BE SELF-CLOSING SHALL NOT BE FITTED WITH HOLD-BACK HOOKS. [name withheld] A DOOR LEADING TO A LIFT/STAIRWAY ON DECK 4 HELD OPEN WITH TWINE. EXAMINERS ALSO OBSERVED A DOOR LEADING TO AN ESCAPE HATCH IN THE ENGINE ROOM WEDGED OPEN. BOTH DOORS ARE REQUIRED TO BE SELF CLOSING ACCODRING TO THE FIRE CONTROL PLAN.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 7 March 2023
Resolved
...THESE MEASURES SHOULD INCLUDE THE REGULAR TESTING OF THE STAND-BY ARRANGEMENTS AND EQUIPMENT OR TECHNICAL SYSTEMS THAT ARE NOT IN CONTINUOUS USE. PSCO DISCOVERED THAT CREW HAS NOT BEEN PERFORMING ADEQUATE TESTS OF THE VESSEL'S HYPER MIST SYSTEM IN UNMANNED MACHINERY SPACES. UPON REVIEW OF THE SMS, IT WAS FOUND THERE WERE NO INSTRUCTIONS FOR THE TESTING OF THE HYPER MIST SYSTEM.
-74SOLAS(20)IX/3.1
-ISM CODE PART A/10.3
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 7 March 2023
Resolved
EVERY CANDIDATE FOR CERTIFICATION SHALL: HAVE COMPLETED APPROVED EDUCATION AND TRAINING AND MEET THE STANDARD OF COMPETENCE SPECIFIED IN SECTION A-III/2 OF THE STCW CODE. TABLE A-III/1 REQUIRES KNOWLEDGE OF FIREFIGHTING SYSTEMS. [name withheld] WITH PROCEDURES FOR ACTIVATION AND TESTING OF THE WATER MIST SYSTEM. VESSEL IS CLASSED FOR UMS WHICH REQUIRES AUTOMATIC OPERATION.
-STCW III/2.2.2
01 - Certificates & Documentation › 011 - Ships Certificates › Safety Management Certificate (SMC/ ISM)
Issued 28 February 2023
Resolved
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND CONVENTIONS. THE OBJECTIVE NATURE OF DEFICIENCIES 02 AND 03 DEMONSTRATE THE VESSEL IS NOT BEING MAINTAINED TO INTERNATIONAL STANDARDS, BRINGING INTO QUESTION THE VALIDITY OF THE SAFETY MANAGEMENT CERTIFICATE
ISSUED PURSUANT TO THE ISM CODE. AN EXTERNAL AUDIT IS
REQUIRED TO BE COMPLETED PRIOR TO DEPARTURE FROM PORT.
74SOLAS(20)IX/3.1
ISM A/10.1
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 28 February 2023
Resolved
CARGO SHIPS SHALL CARRY AT LEAST ONE RESCUE BOAT COMPLYING WITH THE REQUIREMENTS OF SECTION 5.1 OF THE CODE. VESSEL DOES NOT HAVE A RESCUE BOAT ON BOARD.
74SOLAS(20)III/31.1.1.1
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 February 2023
Resolved
CARGO SHIPS SHALL CARRY ONE OR MORE TOTALLY ENCLOSED LIFEBOATS COMPLYING WITH THE REQUIREMENTS OF SECTION 4.6 OF THE CODE OF SUCH AGGREGATE CAPACITY ON EACH SIDE OF THE SHIP AS WILL ACCOMMODATE THE TOTAL NUMBER OF PERSONS. VESSEL DOES NOT HAVE A LIFEBOAT ON BOARD.
74SOLAS(20)III/31.1.1.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 July 2021
Resolved
THE RING, LINES AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK GROUND OR IN BLACK ON A LIGHT GROUND. THEY SHALL BE PERMANENTLY MARKED ON THE SIDES OF THE SHIPS TO THE SATISFACTION OF THE ADMINISTRATION. THE MARKS SHALL BE PLAINLY VISIBLE AND, IF NECESSARY, SPECIAL ARRANGEMENTS SHALL BE MADE FOR THIS PURPOSE. PSCO OBSERVED THAT STBD LOAD LINE MARKS NO LONGER CONTRASTED IN COLOR TO SHIPS HULL. CITE: ICLL(88) I/8
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 15 July 2021
Resolved
THE CONDITIONS OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ONBOARD. PSCO OBSERVED IMPROPER SECURING OF A BACK FILL FILTERING SYSTEM BY USE OF A RATCHET STRAP VERSE ORIGINAL MANUFACTURING TURN-BUCKLE. CITE: 74SOLAS(20) I/11(a)
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 July 2021
Resolved
ARRANGEMENTS OF THE EMERGENCY LIGHTING SYSTEM SHALL BE THAT A FIRE OR OTHER CASUALTY IN SPACES CONTAINING THE EMERGENCY SOURCE OF ELECTRICAL POWER. PSCO OBSERVED 01 LIGHT INOPERABLE. CITE: 74SOLAS(20) II-1/41.2.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.