Records from 2012 to 2026. Most recent: inspection, 28 May 2026.
Documentation record
Registered dimensions (L × B × D)167.8 ft × 30.0 ft × 14.1 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)167.8 ft × 30.0 ft × 14.1 ft
ITC tonnagegross 449 / net 134
BuilderBREAUX BROS ENTERPRISES INC · LOREAUVILLE, LA, UNITED STATES · built 2012
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 19 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it449 - Convention (Subpart B), Gross Ton
97 - Regulatory (Subpart C or D), Gross Ton
134 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 30
28 May 2026
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8367545
22 September 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8238682
4 September 2025
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8227372
4 September 2025
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8234663
19 September 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8007785
3 June 2024
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7926464
23 May 2024
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7917582
17 May 2024
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7929180
9 January 2024
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7846304
6 December 2022
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7605158
10 August 2022
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7529596
18 May 2022
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7453107
28 October 2021
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7341138
9 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108874
30 September 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7068412
17 April 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6940293
20 November 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6859020
16 October 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6835003
16 September 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6850051
12 September 2018
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6538619
10 May 2018
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6411323
28 December 2017
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6329647
29 November 2017
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6314589
16 August 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6242502
13 July 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5938486
8 July 2016
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5934240
24 February 2016
Administrative Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5822156
12 May 2014
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4880431
11 May 2014
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4872258
29 June 2012
Plan Review (Other than "T")
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 4398454
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 8 December 2022
Resolved
The water from the exhaust must pass through the entire length of the exhaust pipe. Both port and starboard outboard wet exhaust are leaking at the flanges. – 46 CFR 182.425(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2023
Resolved 6 January 2023
Resolution: All leaks were repaired and tested.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 6 December 2022
Resolved
On a vessel of more than 65 feet in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces. The onboard PA system is not audible throughout the accommodation spaces of the vessel. – 46 CFR 184.610(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2023
Resolved 6 January 2023
Resolution: The PA system was repaired and tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 16 October 2019
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Port side life ring on weather deck was deteriorated. The seal around the life ring was exposed and water had intruded to the internal foam. Owner shall replace the unserviceable life ring with one approved IAW 46 CFR 160.050 or 46 CFR 160.150.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 29 October 2019
Resolution: Received receipt of purchase and picture of new lifering.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 13 July 2016
Resolved
Rafts not set for free-float conditions. Painter line attached directly to vessel, bypassing weak link.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2016
Resolved 13 July 2016
Resolution: Ship's crew properly attached painter line to weak link prior to completion of inspection.
Communications › Audible Communications › Horn/Whistle
Issued 13 July 2016
Resolved
Air horn inop
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 July 2016
Resolved 13 July 2016
Resolution: Air horn fixed and tested, verified by ABS surveyor onboard.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 13 July 2016
Resolved
Missing signage for CO2 storage space IAW 46 CFR 185.612 (g)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 July 2016
Resolved 27 July 2016
Resolution: Signs posted
Construction/Loadline › Structures › Machinery Space Opening
Issued 13 July 2016
Resolved
Reseal deck hatches prior to operation. Soft patches for removal of engines not properly sealing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 August 2016
Resolved 20 October 2016
Resolution: Deck hatches resealed.