Records from 2020 to 2023. Most recent: inspection, 10 April 2023.
Inspection history · 5
10 April 2023
PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7663818
29 August 2021
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7299260
29 August 2021
Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7299318
5 May 2021
PSC B
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7190095
27 February 2020
Deficiency Check · PSC B · ISM Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6913229
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 February 2020
Resolved
The Company and the ship shall comply with the requirements of the International Safety Management Code. For the purpose of this regulation, the requirements of the code shall be treated as mandatory. In meeting these requirements, the Company should ensure that: .1.) Inspections are held at appropriate intervals. 2.) Any non-conformity is reported with its possible cause, if known. 3.) Appropriate corrective action is taken, and 4.) records of these activities are maintained. Upon inspection of the ship's maintenance records, it was found that the ship's general emergency alarm and public address systems have been inoperable since 04JAN2020. During the PSC exam on 27FEB2020, the Captain confirmed the non-conformity had not been reported and that no corrective action had been taken.
74SOLAS(14)IX/3.1
ISM CODE 10.2
30 a.b.c.
Action required: 30 - Ship detained
Resolved 11 March 2020
Resolution: See attached Class/Flag report
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 27 February 2020
Resolved
The Safety Management System should include procedures ensuring that non-conformities, accidents, and hazardous situations are reported to the Company, investigated, and analyzed with the objective of improving safety and pollution prevention. According to weekly maintenance records, both the general emergency alarm, and the public address system were inoperable since 04JAN2020 and there was no report made to the Company until 27FEB2020 while the PSC exam was being conducted.
74SOLAS(14)IX/3.1
ISM CODE 9.1
30 a.b.c.
Action required: 30 - Ship detained
Resolved 3 March 2020
Resolution: An ISM additional audit in the scope of initial audit has been carried out and a non-conformity has been endorsed.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 27 February 2020
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The rescue boat's propeller was not engaging properly due to faulty remote operating cable.
74SOLAS(14)III/20.2
30 a.b.c.
Action required: 30 - Ship detained
Resolved 3 March 2020
Resolution: Existing throttle cable has been repaired and working satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 27 February 2020
Resolved
Muster and embarkation stations shall be illuminated by lighting supplied from the emergency source of power required by regulation II-1/42 or II-1/43 as appropriate. Upon inspection of the emergency lighting at the freefall lifeboat and rescue boat, all 04 lights were inoperable.
74SOLAS(14)III/11.4
17 a.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2020
Resolution: Emergency lighting bulbs at the freefall lifeboat and the rescue boat have been renewed and all 04 lights are operational.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 February 2020
Resolved
Bilge wells in periodically unattended machinery spaces shall be located and monitored in such a way that the accumulation of liquids is detected at normal angles of trim and heel, and shall be large enough to accomodate easily the normal drainage during the unattended period. 04 bilge alarms in the main machinery space were tested. No audible alarms sounded in main control and no alarms registered on the engineer's alarm panel.
74SOLAS(14)II-1/48.1
17 a.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2020
Resolution: Vessel's crew and representative (superintendent) were able to troubleshoot and rectify the issue prior to the end of the PSC exam.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 27 February 2020
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. During the exam, PSCO discovered that the free fall lifeboat's steering system was initially inoperable. Crew was able to repair steering system prior to departure and the conclusion of the exam.
74SOLAS(14)III/20.2
17 a.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2020
Resolution: Vessel's crew and representative (superintendent) were able to troubleshoot and rectify the issue prior to the end of the PSC exam.