MAURY USCG vessel records
← All vessels

FRONTIER ROSE

FRONTIER ROSE is a freight ship. The Coast Guard has recorded 3 inspections since 2019, most recently in September 2021, along with 4 deficiencies — 1 with no resolution recorded —.

Records from 2019 to 2021. Most recent: inspection, 29 September 2021.

Built
Not recorded
Last inspected
29 September 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 September 2021
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2019–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9487988
1168181
Flag
JAPAN
Maury page id
psix-1168181

Documentation record

Tonnage as PSIX records it93183 - Simplified, Gross Ton
93183 - Convention (Subpart B), Gross Ton
60013 - Simplified, Net Ton
205516 - Displacement, Ton
60013 - Convention (Subpart B), Net Ton
179266 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

29 September 2021 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7317763
10 September 2019 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6808787
3 September 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6802248

Deficiency record · 4

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 29 September 2021 Resolved
The machinery shall be of a design and construction adequate for the service for which they are intended. PSCO observed a steady stream of fuel leaking from A/E numbers 1 and 2, and spraying from cylinder one on A/e number 1.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 September 2021
Resolved 30 September 2021
Resolution: Crew overhauled #1 and #2 aux Engine duplex fuel oil strainer and found o-rings worn. Crew replaced o-rings. Witnessed running of aux engines and surveyed fuel oil lines with no leaks.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 3 September 2019 Resolved
14104 - The 15ppm bilge alarm should record date, time, and alarm status and operating status of the 15 ppm bilge separator. The recording device should also store data for at least 18 months and should be able to display a protocol for official inspections. The bilge alarm recording device had no recorded history of OWS operations which were recorded in the ORB for entries up to and including August 28, 2019. MARPOL I/14.7, Resolution MEPC. 107(49)4.2.9
Action required: 15 - Rectify deficiencies by next port
Resolved 10 September 2019
Resolution: Vessel provided class report clearing addressing the deficiency.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 3 September 2019 No resolution recorded
01315 - Any failure of the oil filtering equipment shall be recorded in the oil record book part I. No entry was made in the ORB for the failed bilge alarm recording device and attempted repairs on and around August 31, 2019 by ship's crew. MARPOL I/17.5
Action required: 15 - Rectify deficiencies by next port
Resolution: Vessel provided class report clearing addressing the deficiency.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 3 September 2019 Resolved
02101 - ALL ACCESS OPENINGS IN BULKHEADS AT ENDS OF ENCLOSED SUPERSTRUCTURES SHALL BE FITTED WITH DOORS THAT ARE WEATHER TIGHT WHEN CLOSED. PSCO OBSERVED ALL DOORS ON MAIN DECK NOT CLOSING PROPERLY, ALLOWING LIGHT PAST THE SEALING GASKETS.   ICLL (88 PROTO) 12.1
Action required: 10 - Deficiency Rectified
Resolved 3 September 2019
Resolution: Corrected on the spot

Ownership record