MAURY USCG vessel records Sign in
← All vessels

ARCADIA

ARCADIA is a 2012 freight ship. The Coast Guard has recorded 10 inspections since 2014, most recently in September 2025, along with 2 deficiencies — 1 with no resolution recorded — and 5 operational controls.

Records from 2014 to 2025. Most recent: inspection, 29 September 2025.

Built
2012
Last inspected
29 September 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9635999 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1168194
Flag
LIBERIA
—
Maury page id
psix-1168194

Inspections, by type

…with no type recorded6
…past their stated due date1
Years with a record 6 calendar years (2014–2025)
The 10 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it32839 - Convention (Subpart B), Gross Ton
19559 - Convention (Subpart B), Net Ton
58018 - Dead Weight, Metric Ton
68970 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 10

29 September 2025 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8243203
15 March 2025 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8094383
5 March 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8088681
5 March 2025 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 8088896
17 March 2023 PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7652379
2 March 2023 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7644344
31 July 2020 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7017694
18 July 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6743892
22 July 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6478437
13 August 2014 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4944557

Deficiency record · 2

10 - Safety of Navigation › N/A - No Subsystem › Speed and distance indicator
Issued 29 September 2025 No resolution recorded
Each vessel required to be fitted with an ARPA must be fitted with a device to indicate speed and distance of the vessel through water or over ground. The vessel reported the speed log is inoperable. 33 CFR 164.40 40ac
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 1 October 2025 — due date passed with no resolution recorded
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 13 August 2014 Resolved
0715 - Detection - Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. - Vessel had no means of testing heat/flame detectors. - 74 Solas(2009 cons.) II-2/14
Due 12 September 2014
Resolved 22 July 2018
Resolution: Verified presence of means for testing heat/flame detectors.

Ownership record