MAURY USCG vessel records
← All vessels

POCAHONTAS

POCAHONTAS is a freight ship. The Coast Guard has recorded 15 inspections since 2016, most recently in December 2017, along with 19 deficiencies and 5 operational controls.

Records from 2016 to 2017. Most recent: operational control imposed, 28 December 2017.

Built
Not recorded
Last inspected
26 December 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9376892
1168315
Flag
MARSHALL ISLANDS
Maury page id
psix-1168315

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded4
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it17108 - Dead Weight, Metric Ton
24558 - Displacement, Metric Ton
16162 - Convention (Subpart B), Gross Ton
6128 - Convention (Subpart B), Net Ton
16162 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 15

26 December 2017 NPV Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6329059
15 November 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6304641
13 September 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5999427
26 July 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5953669
24 July 2016 In-Service Inspection · NPV Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5951141
21 July 2016 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5948023
17 July 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5948119
14 July 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5946807
13 July 2016 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5939819
7 July 2016 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5932525
3 July 2016 In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5927358
1 July 2016 Ballast Water Examination · Deficiency Check · ISPS II Exam · In-Service Inspection · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5923481
22 June 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5915187
4 February 2016 Deficiency Check · PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5809385
4 February 2016 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5810097

Deficiency record · 19

Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 26 December 2017 Resolved
Each emergency generator set arranged to be automatically started shall be equipped with starting devices approved by the administration. A second source of energy shall be provided for an addtional three starts within 30 mins unless manual starting can be demonstrated. The vessels secondary means of start is hydraulic. The start valve is not operational. The valve is leaking hydraulic oil, and is not operating as designed. SOLAS 74 (2004) CH II-1 Reg 44
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2017
Resolution: Vessel was able to perform the maintenance necessary & repair the secondary means of start mechanism for the Emergency Generator.
Lifesaving › Lifeboat Equipment › Rocket Parachute Flare
Issued 15 November 2017 Resolved
The normal equipment of every lifeboat shall consist of four rocket parachute flares. PSCO found only two rocket parachute flares onboard lifeboat. SOLAS (2014) III/34 LSA 4.4.8.13
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2017
Resolved 15 November 2017
Resolution: Received report from Agent informing us that they received two new rocket parachute flares for the lifeboat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 November 2017 Resolved
Not less than one half of the total number of lifebuoys shall be provided with lifebuoy self-igniting lights complying with the requirements of paragraph 2.1.2 of the code. One lifebuoy self-igniting light was inoperable. SOLAS (2014) III/7 LSA 2.1.2
Action required: 705 - Other - as specified
Due 15 November 2017
Resolved 15 November 2017
Resolution: Deficiency was corrected on the spot.
Personnel › Training › Familiarization Training
Issued 13 September 2016 Resolved
0615 - Rescue Boats - Every crew member assigned emergency duties shall be familiar with the duties before the voyage begins. Crew unfamiliar with launching and recovering rescue boat. 74SOLAS(14) ChIII/Reg.19.2.1
Action required: 705 - Other - as specified
Due 27 September 2016
Resolved 23 September 2016
Resolution: Received class survey statement attesting to issued deficiency being rectified. Corrective measures taken include adding shackles to slack chains in the handrails and additonal crew training conducted.
Engineering › Compressed Air System (start air) › Compressor
Issued 24 July 2016 Resolved
1410 Sufficient power for going a stern shall be provided to secure proper control of the ship in all normal circumstances. While the vessel was maneuvering to GCT 1, the vsl experienced a loss of propulsion; main engine failed to respond to astern orders. Vessel has experienced multiple losses of propulsion while transiting in US waters since 01JUL16. SOLAS (2014) II-1/28.1 30ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2016
Resolution: Received Class report from surveyor stating all repairs have been made and main engine is operational.Class report is enclosed.
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 24 July 2016 Resolved
2525 Every company should develop, implement, & maintain a SMS to include instructions & procedures to ensure safe operations of the ship in compliance with relevant international & flag legislation. Vsl has failed to properly report multiple past due maintenance items performed on main engine, IAW “fleet operations” within the company SMS. SOLAS (14) IX/3.1 ISM Code Part A/1.4.2 & 1.4.3. 30bc
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2016
Resolution: Verified that ISM Audit was conducted.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 24 July 2016 Resolved
1020 Fire control panels should be located on the nav bridge or in the manned control station, clear information should be displayed on each indicating unit While testing the smoke detection alarms in the E/R the PSCO observed that the fire alarm panel indication system did not correspond with the graph that the vsl had created to determine fire locations. SOLAS (2009)II-2/7.2.2 FSS Code 9.2.5.1.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2016
Resolution: Verfiied Fire alaram panel indication system corresponded with graph the vessel had created.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 21 July 2016 Resolved
74 SOLAS (2004 Cons Ed)II-I/Reg.28.1 - Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. Vessel reported a delay/loss of astern propulsion for approximately 20-30 seconds while approaching the pier.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 July 2016
Resolved 13 September 2016
Resolution: Deficiency issued by SEC NY has been rectified. Vessel was detained by Flag, Marshall Islands, in Miami until the def was rectified. Received class report from DNV GL.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 14 July 2016 Resolved
Sufficient power for going astern shall be provided to secure proper control of the ship in all normal circumstances. Once vessel shifts from HFO to Low Sulfur Fuel, the main engine fails to make propulsion astern. SOLAS (04) Chp.II-I/Reg.28.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 July 2016
Resolution: Engine was inspected by the engine manufacturer's service rep and damaged air pipe was repaired by the crew. Starting of the engine was tested serveral times,going ahead and astern.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (air intake)
Issued 3 July 2016 Resolved
Means shall be provided whereby normal operation of propulsion machinery can be sustained for pneumatic or electrical means for control in main propulsion machinery. Main engine intermittenly fails to make propulsion astern.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2016
Resolved 5 July 2016
Resolution: Damaged starting air pipe replaced by ship crew.
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (air start)
Issued 1 July 2016 Resolved
The machinery and fittings shall be of a design and construction adequate for service for which they are intended. While the vessel was maneuvering to garden City Terminal on the Savannah iver, the vessel had a loss of propulsion; the main engine failed to respond to astern orders on the EOT. SOLAS 74 (04 cons.)/CH.II-1/Reg 26.1/ 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2016
Resolved 1 July 2016
Resolution: recieved report from DNV-GL attesting to full and proper operation of the main engine.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 1 July 2016 Resolved
Doors fitted in boundary bulkheads of machinery of category A shall be reasonably gas tight, and self closing. The self closing “A” closing door leading to the provision stores does not close properly and it is missing a latch. SOLAS 74 (04 cons)/CH II-2/Reg 9.4.2.1 / 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 July 2016
Resolution: Recieved report from DNV-GL attesting to the proper operation of the door latch.
Engineering › Compressed Air System (control) › Fitting
Issued 1 July 2016 Resolved
Pressure vessels associated piping shall be so installed and protected due regard to other hazards. The No.2 air receiver pressure gauge was found inoperable at local station. SOLAS 74 (04 cons)/ CH. II-1/Reg. 26.1 / 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 July 2016
Resolution: DNV-GL imposed a condition to have the guage to be renewed by 1SEP2016.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 July 2016 Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. Emergency lighting located at the STBD survival craft muster location was found inoperable. SOLAS 74 (04 cons)/ CH. III/Reg.9.1.4/ 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2016
Resolved 1 July 2016
Resolution: Recieved report from DNV-GL attesting to the proper operation of the liferaft station embarkation light; cable seal repaired.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 1 July 2016 Resolved
Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. Smoke detector above the fire pump was found to be covered with a rag. Rag was removed and detector tested in presence of PSCOs. SOLAS 74 (04 cons)/ CH. II-2/Reg.14.2.1.1.2 / 10C
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 1 July 2016
Lifesaving › Inflatable Liferafts › Float Free
Issued 1 July 2016 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. The STBD liferaft seapainter was incorrectly installed to the hydrostatic release weak-link. PSCO witnessed the proper connection of the painter line and hydrostatic release. SOLAS 74 (04 cons)/ CH. III/Reg. 20.2/ 10C
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 1 July 2016
Engineering › Compressed Air System (start air) › Valve
Issued 4 February 2016 Resolved
74SOLAS(14)I/11(c) Whenever an accident occurs to a ship or a defect is discovered... the nominated surveyor or RO responsible for issuing the relevant certificate, who shall cause investigations to be initiated. Loss of propulsion in Delaware River.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 February 2016
Resolved 11 February 2016
Resolution: MAN Diesel Turbo technician attended vessel to rectify propulsion incidents. Replaced worn fuel pump and plungers.Broken main engine piston ring was at fault as well.Overhauled main engine units #2 3 4 and 7.Overhauled FO pumps 2, 3, 4 and 6. See report
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 4 February 2016 Resolved
MARPOL 73/78 Annex I/ 14.6: Oil Content Meter not operating IAW MEPC 107(49) in that dates are not accurate/ at least 9 months behind correct date. Therefore oil record book does not correspond w/ history in oil content meter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 March 2016
Resolved 22 June 2016
Resolution: Class report provided
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 4 February 2016 Resolved
74SOLAS(14)IX/ 3.1 and ISM Code Part A 10.1: OCM issue not reported to company. Multiples discrepancies were found with lifesaving, firefighting, ILO w/ documentation provided to Flag State. Recommend ISAM audit.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 June 2016
Resolution: Class report provided

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.