CHARLES is a 2011 freight ship. The Coast Guard has recorded 12 inspections since 2017, most recently in December 2024, along with 9 deficiencies and 1 operational control.

Records from 2017 to 2024. Most recent: inspection, 26 December 2024.

Built
2011
Last inspected
26 December 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 December 2024
…with no type recorded5
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2017–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9595175
1168507
Flag
LIBERIA
Maury page id
psix-1168507

Documentation record

Tonnage as PSIX records it22662 - Convention (Subpart B), Gross Ton
12531 - Convention (Subpart B), Net Ton
45336 - Displacement, Metric Ton
37193 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

BIG RAY II Passenger (Inspected) · MISLE 440143 · 24 September 2024 · activity 8013858

Inspection history · 12

26 December 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8050867
24 September 2024 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8013858
17 June 2023 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7715751
29 May 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7699798
24 August 2018 ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6520828
22 May 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6411830
14 December 2017 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6322654
14 December 2017 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6323966
11 October 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6285437
5 April 2017 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6115571
4 April 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6117690
1 April 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6115639

Deficiency record · 9

07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 26 December 2024 Resolved
PSCO identify 02 self closing fire doors that have hold backs. Verefy fire control plan and confirm that doors are self closing. Flag state inspector was onboard and will follow up the report.
Condition: Improper Installation
Due 15 January 2025
Resolved 7 January 2025
Resolution: RCVD email from flag state surveyor correcting the deficiencies
Fire Fighting › Fixed Fire Detection System › Flame Detectors
Issued 22 May 2018 Resolved
0715- FIRE FIGHTING APPLIANCES (DETECTION)- A fixed fire detection and alarm system shall be of an approved type and comply with the code. Suitable instructions ford testing and maintenance shall be provided. Detector shall be periodically tested using equipment suitable for the types of fires to which the detector is designed to respond. No testing procedures were found for ship's smoke, heat and flame detectors. Crew stated that cigarette lighters are used to test flames detectors. 74 SOLAS (2014 Cons.)II-2/7.2.2 FSS CODE CHAP. 9.2.5.2 15 a c
Action required: 15 - Rectify deficiencies by next port
Resolved 13 June 2018
Resolution: Received corrective action report from company along w/ class report rectifying deficiency.
Lifesaving › Rescue Boat › Construction
Issued 5 April 2017 Resolved
0615-Rescue Boats-Safety devices shall be fitted in order to prevent overstressing of davit arms. The limit switch was inoperable. Electrician was aware of the problem and notified [name withheld] 74(2014)III/34, LSA Code 6.1.2.7 17a.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2017
Resolved 7 April 2017
Resolution: Received class report from NKK satisfying requirement.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 April 2017 Resolved
1730-Oily water seperating equipment- Any ship 10,000 gross tons shall be fitted with oil filtering equipment complying with paragraph 7. Oily water seperator did not work due to high current alarm from a siezed bilge pump. MARPOL ANNEX I 14.2 17a.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2017
Resolved 7 April 2017
Resolution: Received class report from NKK satisfying requirement.
Documentation › Logs/Records › Oil Record Book
Issued 5 April 2017 Resolved
1710-Oil record book- Each operation shall be recorded without delay in the oil record book. PSCO noticed that the oil record book times did not match with the history on oil filtering equipment. MARPOL ANNEX 1 17.4 16A
Condition: Invalid
Action required: 705 - Other - as specified
Due 19 April 2017
Resolved 7 April 2017
Resolution: Received class report from NKK satisfying requirement.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 5 April 2017 Resolved
0199-Other(transfer procedures)- Transfer procedures required by 33CFR155.720 must be available for inspection. Transfer procedures were not available for inspection. 33CFR155.740 40c.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 5 April 2017
Resolved 7 April 2017
Resolution: Received oil transfer procedures from vessel satisfying requirements.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 5 April 2017 Resolved
0199-Other(Hydrostatic Test Records)- No person shall conduct transfer operations unless the vessel tests and inspects the equipment in accordance with the paragraphs B,C, and F of this section. PSCO discovered there were not hydrostatic test records for bunker lines on board. 33CFR156.170 10C.
Condition: Invalid
Action required: 703 - Prior to bunkering operations
Due 5 April 2017
Resolved 5 April 2017
Resolution: Received, reviewed and accepted proper documentation stating the deficiency was rectified. Captain provided proof of hydrostatic test records.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 5 April 2017 Resolved
0199-Other(Vessel Response plan)- The vessel owner or operator must ensure that they have a copy available. Vessel did not have a Vessel Response plan onboard. 33CFR155.5030(g)(1) 10C.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 5 April 2017
Resolution: Received, reviewed and accepted proper documentation stating the deficiency was rectified. Captain provided a copy of the VRP.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 5 April 2017 Resolved
0199-Other(VGP)- The vessel master could not provide and was not aware of the requirements outlined in the VGP, PSCO instructed that they obtain and read the VGP. 33 U.S.C. 1251 10C.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 5 April 2017
Resolution: Received, reviewed and accepted stating the deficiency was rectified. Captain provided a VGP.