← All vessels
TECOPA
TECOPA is a 2012 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 2016, most recently in September 2025, along with 38 deficiencies, 1 operational control and 12 casualty investigations between 2013 and 2022.
Records from 2013 to 2025. Most recent: inspection, 18 September 2025.
- Built
- 2012
- Last inspected
- 18 September 2025
- Documentation
- Valid · documentation file of 10 August 2026
- Deficiencies
- 38 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 12 investigations · 2013–2022
Identity
1242969
1168760
Flag
UNITED STATES
Maury page id
psix-1168760
Inspections, by type
…with no type recorded10
Years with a record
10 calendar years (2016–2025)
The 42 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.
Documentation record
Registered dimensions (L × B × D)59.7 ft × 24.0 ft × 6.5 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)59.7 ft × 24.0 ft × 6.5 ft
ITC tonnageNot recorded
BuilderKVICHAK MARINE INDUSTRIES INC · SEATTLE, WA, UNITED STATES · built 2012
Hull materialAluminum
PropulsionDiesel
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHAVASU LAKE, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 25 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.
Inspection history · 42
18 September 2025
Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8239248
10 September 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8179690
23 January 2025
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8069212
10 September 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7997207
23 June 2024
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7943506
6 September 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7789799
30 January 2023
Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7640379
7 September 2022
Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7541954
6 June 2022
Examination of Repairs · Drydock Extension · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7471918
24 March 2022
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7418220
24 March 2022
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7433383
12 March 2022
Administrative Inspection · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7411684
31 August 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7308482
6 March 2021
Examination of Repairs · Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7155310
5 March 2021
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7162919
19 February 2021
Damage Survey · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7142917
10 February 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7138494
8 February 2021
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7149060
1 December 2020
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7104600
1 December 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7109238
24 September 2020
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7071771
19 August 2020
In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7041966
22 July 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7013492
21 July 2020
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7019456
25 October 2019
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6842026
11 September 2019
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6814312
22 July 2019
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6759070
11 July 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6760065
18 June 2019
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6718116
14 June 2019
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6734923
22 January 2019
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6613295
5 September 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6518889
19 August 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6527682
4 August 2018
Deficiency Check · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6502650
4 August 2018
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6505835
7 February 2018
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6356539
24 October 2017
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6288720
31 May 2017
Deficiency Check · Examination of Repairs · Damage Survey · Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6199678
4 May 2017
Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6153804
8 December 2016
Annual Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6054923
29 August 2016
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5986998
4 March 2016
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5827332
Deficiency record · 38
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 September 2025
Resolved
General design, installation, and maintenance requirements. Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Exposed wire nuts in the starboard engine room. Remove wired nuts or place them in a junction box.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 10 September 2025
Resolved
Watertight integrity. A hatch cover must have securing devices and be attached to the frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Wire attaching the hatch cover to the port side lazarette hatch was disconnected.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 23 January 2025
Resolved
Vessel representative reported to Sector San Diego (SSD) that the vessel experienced a grounding while underway with passengers on 21JAN25. Vessel reported no water ingress through the hull. Vessel is prohibited from carrying passengers until a third party underwater dive damage survey is completed on both hulls of the vessel. Any damaged areas identified shall be photographed and measured for evaluation by SSD marine inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 June 2024
Resolved
Vessel's stbd main engine suffered a failure of the attached fuel pump. Prove proper operation of the main engine, prior to carrying passengers.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 January 2023
Resolved
Vessel reported a crack and leak in the side shell after alliding with the dock. Vessel must provide a proposal for permanent repairs.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 September 2022
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems. The ventilation system installed did not fully close as designed. Permanent repairs must ensure the ventilation automatically closes fully when the system is energized.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 September 2022
Resolved
Each ring buoy must be marked in legible block capital letters with the vessels name. One ring buoy did not have the vessels name marked as required.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 June 2022
Resolved
During haul out phase, crop and renew aft port section IVO round hull insert.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 June 2022
Resolved
During haul out phase, Crop and renew starboard aft area IVO cracked stiffener.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2022
Resolved
Vessel suffered steering loss & hydraulic oil contamination to lube oil on stbd engine. Provide determination of cause and repair proposal to Sector San Diego. After repairs are completed, provide sea-trials report to clear this "No-Sail" deficiency.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 August 2021
Resolved
Provide operating instructions, (posted in the wheelhouse) for properly energizing the fire pump. Integrate the procedures into fire drills, train the crew and note in logbook.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 August 2021
Resolved
Provide ring buoy on aft of wheelhouse with new grab lines, existing lines were found wasted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 August 2021
Resolved
The port rudder indicator unit was found inoperable, make proper repairs to port rudder angle indicator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 August 2021
Resolved
Flexible bilge piping was found installed with unapproved hose. Provide proper discharge hoses for bilge pumps in stbd side lazarette.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 31 August 2021
Resolved
A leak was found on the steering ram, repair or replace leaking hydraulic ram on port side rudder.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 8 March 2021
Resolved
Make permanent repairs to repaired crack on starboard
side between frames 1-2, in accordance with repair plan approved by USCG Marine Inspector.
While operating with temporary repair in place; vessel
personnel shall be required to conduct inspection rounds
once an hour (prior to and while in vessel is in
operation). Any changes in the temp repair must be reported immediately to the local USCG OCMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 February 2021
Resolved
Prove proper operation of vessel's propulsion controls and steering controls. Provide root causes of failure(s) and repair plan prior to making permanent repairs. Provide signed statement from USCG licensed Captain confirming satisfactory repairs and sea trial. Due: prior to the carriage of passengers.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 19 August 2020
Resolved
Public address system is inoperable. Must provide an effective means of communicating to passengers in the event of all emergencies and orientations to the satisfaction of the CG Marine Inspector until the public address system is fixed or replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 August 2020
Resolved
Port forward window is cracked. Must replace in kind to the satisfaction of the CG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 July 2020
Resolved
Steering solenoid malfunctioned causing the DCV (directional control valve) for the port steering pump to stay in the open position.
Repair prior to departure and OP TEST
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 11 September 2019
Resolved
Vessel's fire pump operated properly when conducting test, but failed to operate later in the inspection while conducting drills. Issued requirement to prove operation of vessel's fire pump.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 September 2019
Resolved
Repair port hull lazarette bilge pump indicator light. Indicator shows constant running of pump.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 September 2019
Resolved
Replace all grab lines on liferings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 September 2019
Resolved
Replace battery on lifering light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 September 2019
Resolved
Replace 01 un-approved adult life jacket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 September 2019
Resolved
Replace retro-flective tape on 02 child and 01 adult life jackets.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 11 September 2019
Resolved
Provide override instructions for vessel's Sea Fire system.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Masters responsibility and authority
Issued 11 September 2019
Resolved
Provide current DAPI consortium enrollment letter.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 January 2019
Resolved
Maintain all machinery in such a manner to afford adequate protection from machinery failure. Properly reoair all four sheared motor mount on portside main engine and prove operation to the attending Marine Inspector or alternative means.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 22 January 2019
Resolved
provide interim and permanent plan for rectifying future shearing of engine mount bolts for USCG review and approval.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 September 2018
Resolved
All engines and power ventilation in protected spaces of pre-engineered systems shall shutdown on activation. Make generators and new fans shutdown properly.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 5 September 2018
Resolved
Properly mount/wire new fans in E/R's.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 August 2018
Resolved
Fire pump motor appears to have burnt windings and is not functioning.
Construction/Loadline › Hull › Transverse Frame
Issued 24 October 2017
Resolved
Repair cracked frame in STBD Laz compartment.
Engineering › Steering Gear System › Piping
Issued 24 October 2017
Resolved
Hydraulic leak noted on STBD steering unit from either ram seal or hose; repair leak.
Construction/Loadline › Hull › Stiffener
Issued 31 May 2017
Resolved
Crop and renew cracked frames in the aft-most starboard space.
Construction/Loadline › Hull › Bottom Plating
Issued 31 May 2017
Resolved
Haul out for a hull exam.
Construction/Loadline › Hull › Bottom Plating
Issued 4 March 2016
Resolved
Crop and renew area surrounding 4 1/2" long crack located in STBD steering compartment.
Casualty record · 12
5 January 2013Routine · role: Involved in a Marine Casualty · activity 4514561
31 May 2013Routine · role: Involved in a Marine Casualty · activity 4610051
20 December 2013Routine · role: Involved in a Marine Casualty · activity 4776622
19 July 2015Routine · role: Involved in a Marine Casualty · activity 5191764
4 August 2018Routine · role: Involved in a Marine Casualty · activity 6505835
14 June 2019Routine · role: Involved in a Marine Casualty · activity 6734923
11 July 2019Routine · role: Involved in a Marine Casualty · activity 6760065
21 July 2020Routine · role: Involved in a Marine Casualty · activity 7019456
1 December 2020Routine · role: Involved in a Marine Casualty · activity 7109238
8 February 2021Routine · role: Involved in a Marine Casualty · activity 7149060
5 March 2021Routine · role: Involved in a Marine Casualty · activity 7162919
24 March 2022Routine · role: Involved in a Marine Casualty · activity 7433383
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.