MAURY USCG vessel records
← All vessels

LAURA D

LAURA D is a 2012 freight ship. The Coast Guard has recorded 12 inspections since 2017, most recently in July 2024, along with 4 deficiencies.

Records from 2017 to 2024. Most recent: inspection, 30 July 2024.

Built
2012
Last inspected
30 July 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 30 July 2024
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2017–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9589633
1168779
Flag
PORTUGAL
Maury page id
psix-1168779

Documentation record

Tonnage as PSIX records it65976 - Convention (Subpart B), Gross Ton
40368 - Convention (Subpart B), Net Ton
121624 - Dead Weight, Metric Ton
142061 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

30 July 2024 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7970304
7 October 2023 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7804918
22 September 2023 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7796637
4 July 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7732256
11 October 2022 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7566136
22 July 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6750540
3 July 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6734898
1 July 2019 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6732534
9 May 2018 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6410066
7 December 2017 Deficiency Check · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6319204
4 December 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6293225
24 October 2017 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6293966

Deficiency record · 4

Documentation › Certificates/Documents › LRIT Conformance Test Report
Issued 4 December 2017 Resolved
0199 - 74 SOLAS (14) V/19-1.4.1 - SHIPS SHALL BE FITTED WITH A SYSTEM TO AUTOMATICALLY TRANSMIT THE INFORMATION SPECIFIED IN PARAGRAPH 5 AS FOLLOWS: SHIPS CONSTRUCTED ON OR AFTER 31 DECEMBER 2008. PSCO NOTED VESSEL COULD PROVIDE LRIT CONFORMANCE TEST REPORT.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 4 December 2017
Resolved 4 December 2017
Resolution: Crew provided LRIT conformance test report.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 December 2017 Resolved
1230 - ICLL 66/25.2 - EFFICIENT GUARD RAILS OR BULWARKS SHALL BE FITTED TO ALL EXPOSED PARTS OF THE FREEBOARD AND SUPERSTRUCTURE DECKS. PSCO FOUND BROKEN METAL SECURING HOOKS FOR CHAINS AT PORT AND STARBOARD PILOT EMBARKATION STATION RAILINGS AT BOW.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2017
Resolution: Carabiners installed to secure chain railings.
Deck/Cargo › Holds/Tanks › Hatch
Issued 4 December 2017 Resolved
1160 - 74 SOLAS (14) I/11 - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PSCO NOTED ALL CARGO HATCH HYDRAULIC GEAR SEALS ARE LEAKING AND MUST BE REPLACED.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 May 2018
Resolution: Received Class reprot attesting to satisfactory repairs.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 4 December 2017 Resolved
0745 - 74 SOLAS (14) II-2/5.2.1.1 - THE MAIN INLETS AND OUTLETS OF ALL VENTILATION SYSTEMS SHALL BE CAPABLE OF BEING CLOSED FROM OUTSIDE THE SPACES BEING VENTILATED. PSCO OBSERVED CREW COULD NOT CLOSE FIRE VENTILATION AT ALL.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 December 2017
Resolution: Fire ventilation closures all capable of being properly secured.

Ownership record