MAURY USCG vessel records Sign in
← All vessels

BONA

BONA is a 2012 freight ship. The Coast Guard has recorded 17 inspections since 2016, most recently in March 2026, along with 3 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 19 March 2026.

Built
2012
Last inspected
19 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9594432 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1168861
Flag
LIBERIA
—
Maury page id
psix-1168861

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2026)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it19943 - Convention (Subpart B), Gross Ton
11325 - Convention (Subpart B), Net Ton
41113 - Displacement, Metric Ton
32844 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 17

19 March 2026 PSC B · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8328535
14 March 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8326014
8 October 2025 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8245277
3 October 2025 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8245891
17 August 2025 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8211735
15 November 2024 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8035273
10 October 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8017299
19 August 2023 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7770722
17 August 2023 COE-Offshore
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7770737
11 October 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7569722
5 October 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7327288
22 December 2020 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7107036
23 October 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6566499
15 May 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6410833
19 April 2017 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6122920
16 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6050043
2 December 2016 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6051138

Deficiency record · 3

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 19 March 2026 Resolved
PSCO observed oil leaks and accumulation in the engine space under all three generator sets. 74SOLAS(09 Cons) Ch.II-2/Reg. 4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2026
Resolution: Recieved class report attesting to the repairs. All in good working order.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 19 March 2026 Resolved
PSCO observed water dripping from the water mist system nozzle over the #3 generator at 100 drops/minute. 74SOLAS(09 Cons.) Ch. II-2/Reg. 14.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2026
Resolution: Recieved class report attesting to the repairs. All in good working order.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 March 2026 Resolved
PSCO observed ballast water piping leaking continuously from gasket. 74SOLAS(24 Cons) Ch. II-1/ Reg. 26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2026
Resolution: Recieved class report attesting to the repairs. All in good working order.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.