MAURY USCG vessel records
← All vessels

VEGA GRANAT

VEGA GRANAT is a 2011 freight ship. The Coast Guard has recorded 2 inspections in 2021, along with 18 deficiencies and 2 operational controls.

Records in 2021. Most recent: operational control imposed, 15 July 2021.

Built
2011
Last inspected
12 July 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9497440
1168878
Flag
LIBERIA
Maury page id
psix-1168878

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 1 calendar year (2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it19994 - Simplified, Gross Ton
402117 - Displacement, Ton
10883 - Simplified, Net Ton
19994 - Convention (Subpart B), Gross Ton
10883 - Convention (Subpart B), Net Ton
31780 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

12 July 2021 Deficiency Check · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7253489
9 July 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7250941

Deficiency record · 18

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 12 July 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed vessel’s grouping and aggregation visual alarm indicators required as per IMO Resolution A.1021(26) were inoperable; for general emergency alarm, CO2 fire extinguishing pre-discharge alarm, fire detection alarm, machinery alarms, telephone alarm, engine-room telegraph alarm, and personnel alarm. The crew is unable to identify which alarm indicator is sounding, therefore cannot properly respond to emergencies. 74SOLAS(20)I/11.a
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2021
Resolution: See class report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 12 July 2021 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids, and ignition sources shall be restricted. PSCO observed oil soaked lagging on heavy fuel oil piping in the overhead space adjacent to the Engine Control Room, oil soaked lagging on piping in the engine room below the deck plate and on the bulkhead side of piping, multiple oil containers with hoses and funnels to varying equipment and spaces, hydraulic oil accumulation in the overhead of the steering gear room from a previously repaired leak, plastic hoses attached to the M.D.O settling tank and bypassing installed funnel and piping, a steam leak in the lube oil purifier room, damaged and missing indicator panels in the purifier room for lube oil and heavy fuel oil purifier, missing or deteriorated lagging around piping in the bilge, and overall uncleanliness of the engine room.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2021
Resolution: Crew secured leak and installed new lagging. See attached class report (Page 6)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 12 July 2021 Resolved
A fixed fire detection and alarm system shall be installed in: periodically unattended machinery spaces. PSCO observed inoperable smoke detector in Engine Control Room. 74SOLAS(09)II-2/7.4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2021
Resolution: Smoke detector replaced. See Class report
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 12 July 2021 Resolved
All hatchways in position 1 and 2 shall be fitted with hatch covers of steel or other equivalent material. Except as provided in regulation 14(2), such covers shall be weathertight and fitted with gaskets and clamping devices. The means for securing and maintaining weathertightness shall be to the satisfaction of the Administration. The arrangements shall ensure that the tightness can be maintained in any sea conditions. PSCO observed over 50% of cargo hatch clamping devices missing/deteriorated from rust and unable to serve their operational purpose. Overall lack of adequate securing devices affects weathertightness of all of the vessel’s cargo holds. ICLL(88) I/16(1)
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Resolved 14 August 2021
Resolution: Vessel affected satisfactory repairs to securing devices, see class report attached.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 July 2021 Resolved
Paint lockers shall be protected by a carbon dioxide system, a dry powder system, a water spraying or sprinkler system, or a system providing equivalent protection, as determined by the Administration. In any case, the system shall be operable from outside the protected space. Acuation control for the CO2 for the paint locker was inaccessible due to the room containing the means of control being secured with a seized lock. PSCO observed crew taking over five minutes to access the CO2 room for the paint locker. 74SOLAS(09)II-2/10.6.3.1
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 July 2021
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 12 July 2021 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. PSCO collected objective evidence that the vessel’s SMS was not adequately being implemented throughout areas of the ship including: weathertightness, alarms, and presence of fire hazards in the engine room. Procedure 16 of the vessel’s SMS states, "Record to be made in maintenance report(s) and documented with pictures. Further, the Crew should draw attention to the dangers of proceeding to sea without fully secured hatch covers." PSCO observed wastage of cargo hatch clamping devices on over 50% of the devices. PSCO observed maintenance record dated 30JUN21 that stated all hatch devices were in fair/good condition; no documents addressed the extensive corrosion. Procedure 07 of the SMS states "The [maintenance] plan consists of several parts, such as monthly procedures, manufacturer maintenance sheets, forms...Safety, fire fighting, pollution and control equipment, pipelines and valves." PSCO observed extensive engine room build up of oil, inoperable alarms, and unauthorized electrical installations. Due to the severity of the discrepancies, an external SMS audit is required before release from detention. 74SOLAS(20)IX/3.1 ISM Code Part A 10
Action required: 30 - Ship detained
Resolved 14 August 2021
Resolution: Vessel completed necessary external audit.
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 12 July 2021 Resolved
On all ships, within the machinery spaces, emergency escape breathing devices shall be situated ready for use and easily visible places. PSCO observed multiple EEBDs not ready for use, with canisters overly charged. 74SOLAS(09)II-2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 August 2021
Resolution: EEBDs were adjusted according the manufacturers maintenance manual. See "Defective No. 17" in "Class Survey 13 Aug 2021" in Documents
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 July 2021 Resolved
Electrical installations shall be such that: the safety of the passengers, crew & ship from electrical hazards will be ensured. PSCO observed a power cable connected to an open electrical control panel in the Engine Control Room leading through a doorway into a separate panel located in an adjacent room. PSCO observed electrical cables originating from an external generator on the outside main deck, running through a watertight bulkhead leading into a breaker within the engine control room that was unsecured on the deck and posed a serious electrical and tripping hazard for the crew. 74SOLAS(20)11-1/40.1.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2021
Resolution: Cables secured and penetration sealed. See Attached Class report
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 July 2021 Resolved
Any main and auxiliary steering gear control system operable from the navigation bridge shall comply with the following: in the event of a failure of electrical power supply to the control system, an audible and visual alarm shall be given on the navigation bridge. PSCO observed unsuccessful test of loss of power alarm for main steering gear system. 74SOLAS(20)II-1/29.8.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2021
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 12 July 2021 Resolved
Hydraulic power-operated steering gear shall be provided with the following: a low-level alarm for each hydraulic fluid reservoir to give the earliest practicable indication of hydraulic fluid leakage. Audible and visual alarms shall be given on the navigation bridge and in the machinery space where they can be readily observed. PSCO observed unsuccessful test of hydraulic low-level alarm. 74SOLAS(20)II-1/29.12.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2021
Resolution: Fuse replaced and function restored. See Class Report
09 - Working and Living Conditions › 091 - Living Conditions › Laundry
Issued 12 July 2021 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. PSCO observed an unprotected splice in the power cable of a washing machine in the officer’s laundry. 74 SOLAS(20)II-1/40.1.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 July 2021
Resolution: Spliced cable was removed and connected properly. See Class Report
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 12 July 2021 Resolved
The ring, lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. They shall be permanently marked on the sides of the ships to the satisfaction of the administration. The marks shall be plainly visible and, if necessary, special arrangements shall be made for this purpose. PSCO observed that both port and stbd load line markings did not match the current ICLL certificate and old load lines were visible on the hull. ICLL(88)I/8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 September 2021
Resolution: Condition of class issued by NKK to repair at next dry dock, deficiency cleared, see documents.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 July 2021 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed the CO2 line servicing the cargo holds had multiple support brackets wasted to the point of no longer supporting the CO2 line. In some places the crew had tied rope from the hydraulic lines to the CO2 line to help support the CO2 line's weight. One section of CO2 piping was unsupported for over twenty-five feet with three support brackets in a row wasted completely through. 74SOLAS(20)II-2/14.2.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 August 2021
Resolution: Supports brackets were renewed throughout the length of the vessel's deck. See "Defective No. 21" on "Class Survey 13 Aug 2021" in Documents
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 12 July 2021 Resolved
The company and the ship shall comply with the requirements of the International Safety Management code. The company should establish procedures, plans and instructions, including checklists as appropriate, for key shipboard operations concerning the safety of the personnel, ship and protection of the environment. PSCO observed that no lockout tag out procedures were established within the ship's safety management system and that an inoperable auxiliary engine was not tagged out as inoperable. 74SOLAS(20)IX/3 ISM CODE 7
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2021
Resolution: Item was addressed as part of ISM Audit. See attached "ISM Audit External 13 Aug 2021" in Documents
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 July 2021 Resolved
Where risk from overspeeding of machinery exists, means shall be provided to ensure that the safe speed is not exceeded. PSCO received notification from master that the engines governor was not working properly. 74SOLAS(20)II-1/27.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2021
Resolution: Vessel received satisfactory Class report for repairs.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 July 2021 Resolved
Unless expressly provided otherwise, every ship shall be provided with a main steering gear and an auxiliary steering gear to the satisfaction of the Administration. The main steering gear and the auxiliary steering gear shall be so arranged that the failure of one of the m will not render the other one inoperative. PSCO received report that steering pump no. 2 was inoperable. 74SOLAS(20)II-1/29.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2021
Resolution: Vessel received satisfactory Class report for repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2021 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provision of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO received a report of an inoperable boiler. 74SOLAS(2)I/11.a.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2021
Resolution: Vessel received satisfactory Class report for repairs.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 9 July 2021 Resolved
All ships of 3,000GT and upwards shall have: a 3 GHz radar, or where considered appropriate by the Administrations, a second 9 GHz radar of other means to determine and display the range and bearing of other surface craft, obstructions, buoys, shorelines, and navigational marks to assist in navigation and in collision avoidance, which are functionally independent of those referred to in paragraph 2.3.2. PSCO received report of an inoperable secondary, S-band radar. 74SOLAS(20)V/19.2.7.1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 July 2021
Resolution: Vessel received satisfactory Class report for repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.