Records from 2014 to 2017. Most recent: inspection, 16 March 2017.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical › Electric Generation Source (emergency) › Generator
Issued 16 March 2017
Resolved
0750- The quick closing valve for the emergency generator fuel tank was inaccessible from outside the space. The handle for the pull wire was protected by a thick plastic cover that was unable to be broken by the crew. It took the crew 10 minutes to access the handle. 74 SOLAS(14) II-2/4.2.2.3.4 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2017
Resolution: Recieved class report.
Fire Fighting › Portable Foam Applicators › General
Issued 16 March 2017
Resolved
0730- Portable foam applicator at bottom deck, port side of the engine room was located in a position that requires crew members to stand on steam pipes to access foam applicator box. 74 SOLAS(14) II-2/10.3.2.4 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2017
Resolution: Recieved class report.
Fire Fighting › Fire Hoses › Condition
Issued 16 March 2017
Resolved
0730- Found 02 20 meter fire hoses missing up forward near bosun store. One hose failed during fire pump test, the other was missing. Crew tried to replace missing hose with another hose from port side between 3 and 4 holds. 74 SOLAS(14) II-2/14.2.1.2 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2017
Resolution: Recieved class report
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 16 March 2017
Resolved
0750- Several self closing fire doors in main vertical stairway did not close properly. 74 SOLAS(14) II-2/9.2.3.4.1 10C
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 16 March 2017
Resolution: Corrected on the spot.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 15 October 2015
Resolved
0615 - Every ship of 400 GT and above shall carry a Garbage Management Plan which the crew shall follow. The plan shall provide written procedures for collecting, storing, processing and disposing of garbage. Vessel has Garbage Management Plan that is not being followed by the crew, which is resulting in mixed garbage. MARPOL Annex V/ Reg. 9.2. - (40a,c )
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 May 2016
Resolved 12 March 2016
Resolution: Class survey provided. Attending surveyor found garbage to be stowed in orderly fashion at the time of inspection. Attending surveyor observed that the vessel had conducted training on garbage stowage and removal on 25October 2015.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 15 October 2015
Resolved
0715 - General arrangement fire plans shall be permanently exhibited for the guidance of the ships officers, showing fire detection and fire extinguishing appliances. Fire Control Plan shows approved helideck but vessel does not meet additional fire fighting requirements for helideck. Vessel is missing 01 fire fighting outfit to meet the 02 additional fire fighting outfit (cont. in narrative)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 May 2016
Resolved 12 May 2016
Resolution: Class survey provided. Vessel received additional new firefighting suit on 15 November 2015, so as to comply with requirements. The new firefighting suit is a Flame Guard MK3.
Lifesaving › Rescue Boat › Propulsion Engine
Issued 15 October 2015
Resolved
0615 - Rescue Boats - Maintenance, testing and inspections of life saving appliances shall be carried out based on the guidelines developed by the orginzation. Guidelines refer to use engines manufacturer's manual for Rescue Boat engine. Vessel could not provide engine manufacturer's manual for Rescue Boat Engine.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 May 2016
Resolved 12 May 2016
Resolution: Class survey provided. Attending surveyor observed the rescue boat manufacture’s manual on board. The engine is a Mercury 25 HP and was operationally tested with no remarks.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 15 October 2015
Resolved
0715 - Detection - The function of fixed fire detection system shall be periodically tested to the satisfaction of the adminstration. Vessel does not have appropiate means or procedures for testing heat and flame detectors.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 May 2016
Resolved 12 May 2016
Resolution: Class survey provided. The vessel received smoke and heat detector poles on 15 November 2015. Attending surveyor randomly tested a selection of detectors with no remarks.