V-117 is a 2000 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in July 2025, along with 22 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: operational control imposed, 25 July 2025.

Built
2000
Last inspected
21 July 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
Maury page id
psix-11692

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
3 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 16

21 July 2025 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8191229
2 July 2024 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7947028
24 May 2024 Damage Survey · Drydock Exam · Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7918785
24 May 2024 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7922762
1 March 2024 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7872860
2 November 2023 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7819391
8 November 2022 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7601814
6 January 2022 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7376735
19 October 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7339886
15 October 2020 Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7078019
20 July 2020 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7011043
5 August 2019 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6773449
9 January 2019 Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6607807
2 July 2018 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6467473
6 July 2017 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6199790
14 June 2016 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5910319

Deficiency record · 22

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 25 July 2025 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Main engine hard to start, not reliable. Affects repairs on propulsion engine. 46CFR182.200 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 August 2025
Resolution: Received video evidence of the repair.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 July 2025 Resolved
A vessel of not more than 7.9 meters (26 feet) in length must carry a minimum of one life buoy of not less than 510 millimeters (20 inches) in diameter. Replaced Life ring with approved type.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 August 2026
Resolution: Life Buoy replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 July 2025 Resolved
If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches). Attach remote device to fuel valve to prevent crew from reaching bellow engine to secure valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 20 August 2025
Resolution: Received video evidence of the repair.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 June 2024 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Vessels forward green and red navigation light is smashed and not operable. Vessel is restricted to day light operations until repaired to the satisfaction of the attending MI. 46 CFR 183.420
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2024
Resolved 2 July 2024
Resolution: Replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Vessel owner needs to replace the Ibuprofen (50 tablets) and eye wash solution in the vessels first aid kit. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 2 July 2024
Resolution: Renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 June 2024 Resolved
A vessel must carry one floating water light, unless it is limited to daytime operation, in which case no floating water light is required. Each floating water light must be approved in accordance with § 161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Each ring life buoy with a floating water light must have a lanyard of at least 910 millimeters (3 feet) in length, but not more than 1,830 millimeters (6 feet), securing the water light around the body of the ring life buoy. Each floating water light installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the water light to be quickly disconnected from the ring life buoy. Vessel has no water light available for use. Vessel is restricted to day light operations until replaced. 46 CFR 180.70 (d)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 10 July 2024
Resolution: Provided
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2024 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. Vessels cage does not cover the engine exhaust piping. Install a guard or heat shielding to prevent accidental burn of vessel crew. No persons are permitted aft of the Captains chair for a minimum of 30 minutes after the engine has ran until repaired. 46 CFR 177.970
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 2 July 2024
Resolution: Heat lagging installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 June 2024 Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. Vessel only has one propulsion engine and the f/o shutoff is installed at the engine. The f/o shut off is required to be at the tank. The shut off at the engine is optional. 46 CFR 182.455 (b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 2 July 2024
Resolution: Relocated to top of fuel tank.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2024 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child sized life jackets were stowed with adult jackets. They have been moved to the forward compartment, mark compartment. 46 CFR 180.78 (a)(5)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 2 July 2024
Resolution: Moved to fwd compartment.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 May 2024 Resolved
Deck rails must be designed and constructed to withstand a point load of 91 kilograms (200 pounds) applied at any point in any direction, and a uniform load of 74 kilograms per meter (50 pounds per foot) applied to the top rail in any direction. Vessel was involved in a reportable marine casualty (grounding) Various handrails and rudder support stanchion were found damaged and requiring repair. Repair to the satisfaction of the attending MI. 46 CFR 177.900 (b)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2024
Resolution: Vessel repairs were satisfactory and cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 March 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 12 March 2024
Resolution: New COI issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 November 2023 Resolved
At least one ring buoy must be fitted with a life line. Each must be buoyant, 60', non kinking, have a diameter of 5/16", breaking strength of 1,124 lbs and be dark in color if synthetic or of a type certified to be resistant to deterioration from ultraviolet light. Current life buoy line is white and cannot be proved as meeting the resistant to ultraviolet light. Replace with line meeting the regulation to the satisfaction of the attending MI. 46 cfr 180.70 (c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2023
Resolved 20 November 2023
Resolution: New life buoy line provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 November 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of International and Inland navigation rules. Vessels port bow red light is not the proper color. Replace to the satisfaction of the attending MI. Vessel is restricted from any night time movement until repaired. 46 CFR 183.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2023
Resolved 20 November 2023
Resolution: Nav lights renewed.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 6 November 2023 Resolved
Unless other wise provided by this subpart each vessel required to have a certificate of inspection is subject to annual vessel inspection fees listed in table 2.10-101. Vessels user fees are overdue and need to be paid. Contact USCG FINCEN to pay fees and provide proof of payment to the attending MI. 46 CFR 2.10-101
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2023
Resolved 20 November 2023
Resolution: Proof of user fee payment provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 October 2021 Resolved
Life ring buoys shall be ready for use at all times. The grab line on the buoy was frayed.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 6 January 2022
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 October 2021 Resolved
Naviagtion lights are required when operating at night or in periods of reduced visibility. The port and starboard lights are extinguished.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 6 January 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 October 2021 Resolved
A portable 5 GPM bilge pump is required. The vessel does not have a portable bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 November 2021
Resolved 6 January 2022
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 July 2020 Resolved
Provide two additional VDS.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 August 2020
Resolved 15 October 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 July 2020 Resolved
Provide 1st aid kit for lifeboats.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 15 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2020 Resolved
Seperate child PFD's and label stowage location. Apply new vsl name on PFD's.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 August 2020
Resolved 15 October 2020
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 20 July 2020 Resolved
Provide one additional rail course along the top of the rails.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 August 2020
Resolved 15 October 2020
Engineering › Fuel Oil Service System › Piping
Issued 6 July 2017 Resolved
Install fuel lines meeting requirements of 46CFR182.720(e).
Condition: Placed in Improper Service
Due 7 August 2017
Resolved 6 July 2017

Ownership record