← All vessels
ONEGO DUERO
ONEGO DUERO is a 2012 freight ship. The Coast Guard has recorded 40 inspections since 2012, most recently in December 2025, along with 26 deficiencies and 10 operational controls.
Records from 2012 to 2025. Most recent: inspection, 29 December 2025.
- Built
- 2012
- Last inspected
- 29 December 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 26 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9580780 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
PEHW
1169246
Flag
NETHERLANDS
—
Maury page id
psix-1169246
Inspections, by type
…with no type recorded10
Years with a record
10 calendar years (2012–2025)
The 40 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it6351 - Convention (Subpart B), Gross Ton
3617 - Convention (Subpart B), Net Ton
12828 - Displacement, Metric Ton
9690 - Dead Weight, Metric Ton
3617 - Convention (Subpart B), Net Ton
12828 - Displacement, Metric Ton
9690 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 40
29 December 2025
In-Service Inspection
Physical examination · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8288415
29 December 2025
Type not recorded
No type recorded · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 8290971
23 June 2025
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8165514
7 April 2025
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8106572
13 December 2024
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8047218
23 October 2024
PSC B · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8023315
3 October 2024
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8013746
25 September 2024
PSC B
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8006149
20 September 2024
Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 8006315
23 May 2024
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7918212
28 April 2024
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7901175
22 April 2024
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7899531
21 April 2024
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7898868
19 April 2024
In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7898418
16 April 2024
PSC B
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7895940
12 December 2023
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7837985
5 December 2023
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7834420
30 November 2023
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7831538
29 November 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7859901
20 November 2023
Administrative Inspection
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7827664
5 September 2023
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7782544
29 July 2022
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7519578
25 July 2022
Administrative Inspection · COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7516485
18 May 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7453498
26 January 2022
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7386155
29 October 2021
PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7341826
4 July 2021
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7243846
13 November 2020
Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7094851
13 November 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7097719
7 May 2020
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6950021
20 February 2020
Ballast Water Examination · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6909866
2 August 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6774723
19 July 2019
PII Safety Exam · Administrative Inspection · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6755474
18 July 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6754248
18 July 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6754369
10 April 2017
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6121401
7 November 2016
ISPS II Exam · Ballast Water Examination · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6035995
22 July 2016
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5941525
25 June 2012
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4356321
16 May 2012
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4305771
Deficiency record · 26
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 25 September 2024
Resolved
The fire resistance of doors shall be equivalent to that of the division in which they are fitted. Division A self-closing boundary door entering the galley was unable to latch and function as intended due to a deformation in the door.
74SOLAS(20)II-2/9.4.2.1
15ac
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 25 September 2024
Resolved
Fire protection systems and firefighting systems and appliances shall be maintained and ready for use. Portable foam applicator hose was damaged, PSCO could not verify the functionality of the applicator.
74SOLAS(20)II-2/14.1.1
15ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 September 2024
Resolved
Machinery, boilers and other pressure vessels associated piping systems and fittings shall be of a designed and construction adequate for the service for which they are intended. Fresh water generation plant is inoperable.
74SOLAS(04)II-1/26.1
50ac
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 25 September 2024
Resolved
The ring lines and letters shall be painted in white or yellow on a dark ground or in black on a light ground. Deck line was painted white with a white background, showing no contrast.
ILLC 66 Annex 1/8
50ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 April 2024
Resolved
The machinery, boilers and other pressure vessels associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO identified a small leak on the stem valve located at emergency Lube Oil shut offs integral tank. Request clarification from Certificate Issuing Authority.
SOLAS 74AM II-I/26, code 40ac.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 April 2024
Resolved
UPDATE SHIPS OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33CFR155.750 PRIOR TO BUNKERING IN U.S. WATERS.
33CFR155.750, CODE c.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 16 April 2024
Resolved
The main inlets and outlets of all ventilation systems shall be capable of being closed from outside the spaces being served. PSCO observed engine room ventilation dampers were inoperable on port and starboard sides.
74SOLAS(20)II-2/5.2.1.1
Action Taken: 17 a.c.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 12 December 2023
Resolved
01-02115-Ships shall be designed, constructed and maintained in compliance with the structural, mechanical and electrical requirements of a classification society which is recognized by the Administration in accordance with the provisions of regulation XI/1, or with applicable national standards of the Administration which provide an equivalent level of safety. The temporary bulkhead on the aft #1 cargo hold was observed unsatisfactorily bowing towards the aft. SOLAS 74 (2004 CONS) Chp. II-1 Reg. 3-1
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 November 2023
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The ship experienced a failure of the bulkhead in the #2 cargo hold, resulting in the cargo shifting and the ship's stability being compromised.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 29 October 2021
Resolved
In meeting these requirements, the company should ensure that: inspections are held at appropriate intervals [10.2.1]; records of these activities are maintained [10.2.4]."The vessel(s) have planned maintenance system organized to ensure that the maintenance of the ship and equipment are carried out at appropriate intervals"[SMS Manual 10. Maintenance of the Ship and the Equipment].
Vessel's SMS does not specify testing intervals and procedures for testing flame detector system. PSCO's did not observe any means of determining either as denoted in deficiency 02.
And internal SMS audit is required within 90 days to focus on maintenance and equipment.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 October 2021
Resolved
Flame detectors shall be tested according to standards EN 54-10:2001 and IEC 60092-504. (FSS Code 9.2.3.1.5)
Crew could not produce any instructions for interval and method of testing flame detectors on board. A class report is required attesting to proper testing and operation of flame detectors onboard.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 October 2021
Resolved
Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the Administration. (74 SOLAS (04) II-1/45.5.4)
PSCO's observed #1 lube oil purifier cable connection pulled loose in the purifier room.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 29 October 2021
Resolved
Each completed page of the Garbage Record Book shall be signed by the master of the ship. (MARPOL 5/10.3.1)
Garbage Record Book was not reviewed and signed by the master since 26AUG21.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 29 October 2021
Resolved
Each completed operation shall be signed by the officer or officers in charge of the operations concerned and each completed page shall be signed by the master of the ship. (MARPOL 1/17.4)
The last completed page of the Oil Record Book Part 1 was not reviewed and signed by the master.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 13 November 2020
Resolved
NO DISCHARGE INTO THE SEA SHALL CONTAIN CHEMICALS OR OTHER SUBSTANCES IN QUANTITIES OR CONCENTRATIONS WHICH ARE HAZARDOUS TO THE MARINE ENVIRONMENT OR CHEMICALS OR OTHER SUBSTANCES. PSCO OBSERVED FUEL OIL COMING FROM AN UNIDENTIFIED PLACE ON VESSEL THAT SPILLED INTO THE WATERWAY (BUFFALO BAYOU). PRIOR TO MOVEMENT VESSEL MUST IDENTIFY SOURCE OF LEAK AND RECTIFY. 78 MARPOL (17) I/15.8
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 November 2020
Resolved
MEANS SHALL BE PROVIDED TO LIMIT ACCUMULATION OF FLAMMABLE VAPOURS. PSCO OBSERVED A POOL OF OIL IN THE ENGINE ROOM, SPECIFICALLY UNDER MAIN ENGINE. 74 SOLAS (14) II-2/4.2
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 November 2020
Resolved
HOLD BACK HOOKS FOR FIRE DOORS NOT SUBJECT TO CENTRAL CONTROL STATION RELEASE ARE PROHIBITED. PSCO OBSERVED 02 ENGINE ROOM FIRE DOORS TIED OPEN WITH LINE. 74 SOLAS (14) II-2/ 9.4.1.1.5.4
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 February 2020
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order. PSCO observed that the free-fall lifeboat engine would not crank. After the chief engineer worked on it the life-boat engine started. 74SOLAS (14) III/20.2 10c
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 20 February 2020
Resolved
All items of life-boat equipment...shall consist of: a total of 3 liters of water per person; and a first-aid outfit. PSCO observed 32 half liters of water for 15 persons and the first-aid kits had expired. 74SOLAS(14) III/34 LSA Code 4.4.8.9 & 4.4.8.20 50a
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 February 2020
Resolved
The master, owner, operator, agent, or person in charge of any vessel equipment with ballast water tanks that operate in the waters of the U.S. must follow these practices: Remove fouling organism on the vessel's hull. PSCO observed marine growth on the vessel's hull. 33CFR151.2050(f) 40c
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 20 July 2019
Resolved
THE LIFEBOAT SHALL BE MANOEUVERED IN THE WATER BY THE OPERATING CREW, AT INTERVALS OF NOT MORE THAN THREE MONTHS.
SHIP'S CREW WASN'T ABLE TO PROVIDE DOCUMENTATION OF THE LIFEBOAT WATER MANOEUVERS.
SOLAS 14 III / 19.3.4.4
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 20 July 2019
Resolved
THE DATES WHEN MUSTERS ARE HELD, DETAILS OF ABANDON SHIP DRILLS AND FIRE DRILLS, DRILLS OF OTHER LIFE SAVING APPLIANCES AND ON BOARD TRAINING SHALL BE RECORDED IN SUCH LOG-BOOK AS MAY BE PRESENTED BY THE ADMINSTRATION.
VESSEL WAS UNABLE TO PROVIDE RECORD OF LOG-BOOK OF ON BOARD TRAINING.
SOLAS 14 III / 19.5
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 20 July 2019
Resolved
COMPRESSED AIR BREATHING APPARATUS SHALL BE FITTED WITH AN AUDIBLE ALARM AND A VISUAL OR OTHER DEVICE WHICH WILL ALERT THE USER BEFORE THE VOLUME OF AIR IN THE CYLINDER HAS BEEN REDUCED TO NO LESS THAN 200L.
ALL FOUR BRETHING APPARATU'S LOW PRESSURE ALARMS WERE NOT WORKING AT THE MOMENT OF THE FIRE DRILL.
SOLAS 14 II-2 / 10.1.2; FSS CODE 3.2.1.2.2
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo Securing Manual
Issued 19 July 2019
Resolved
Appropriate precautions shall be taken during loading and transport of heavy cargoes or cargoes with abnormal physical dimensions to ensure that no structural damage to the ship occurs and to maintain adequate stability throughout the voyage.
No documentation for any precautions nor specific instructions for loading or transportation could be provided for windmill blades, the vessels current cargo.
74SOLAS(14)VI/5.3
17c
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 22 July 2016
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. Lifeboat propeller rudder is not able to turn port or starboard.
Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 16 May 2012
Resolved
Vessel has not submitted a Notice of Intent for the Vessel General Permit (VGP). VGP Part 1.5.1.1, Part 10. MI: [name withheld], [phone withheld], [email withheld], USCG MSU Portland, OR.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National