CARIBBEAN LOYALTY is a 2011 tank ship. The Coast Guard has recorded 12 inspections since 2016, most recently in December 2025, along with 3 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 23 December 2025.

Built
2011
Last inspected
23 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9501150
1170369
Flag
MARSHALL ISLANDS
Maury page id
psix-1170369

Inspections, by type

Years with a record 8 calendar years (2016–2025)
The 12 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it163066 - Convention (Subpart B), Gross Ton
107929 - Convention (Subpart B), Net Ton
364465 - Displacement, Metric Ton
316373 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 12

23 December 2025 Ballast Water Examination · COC-TVE Renew · PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8264471
5 November 2025 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8264689
15 May 2024 COC-TVE Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7903143
3 May 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7906032
17 February 2023 COC-TVE Annual
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7638219
10 February 2022 COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7394002
1 February 2022 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7388898
19 May 2020 PSC B · COC-TVE Annual
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6955152
25 April 2019 COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6654697
31 January 2018 ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6338817
17 January 2018 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6339402
6 November 2016 Ballast Water Examination · ISPS II Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6034831

Deficiency record · 3

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 15 May 2024 Resolved
THE SYSTEM SHALL HAVE AN ALARM TO INDICATE IF THE GAS SAMPLING LINES ARE CLOGGED. CREW WAS UNABLE TO DEMONSTRATE A FLOW FAULT ON FIXED GAS SYSTEM. 74 SOLAS (20) II-2/4.5.10.1.3 FSS CODE 16.2.2.1.6
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 November 2025
Resolution: Vessel submitted closure reports and training logs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 May 2024 Resolved
IN TANKERS, ELECTRICAL EQUIPMENT, CABLES AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. 02 EXPLOSION PROOF LIGHTS FOUND CRACKING ON LENSE IN STBD DECK LOCKER. 74 SOLAS (20) II-1/45.11
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 November 2025
Resolution: Vessel submitted closure supporting doccuments and detailed photos.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 15 May 2024 Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL ASPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. METAL DETERIORATION FOUND ON DECK, INCLUDING 2 STBD GAS TIGHT PIPE FOR TANK GAUGE RADAR. 74 SOLAS (20) I/11
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 November 2025
Resolution: Vessel submitted closure doccuments and detailed photos.