MAURY USCG vessel records
← All vessels

TENDER 9

TENDER 9 is a 2012 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in September 2025, along with 8 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 10 September 2025.

Built
2012
Last inspected
10 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 September 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WUT6768
1170678
Flag
UNITED STATES
Maury page id
psix-1170678

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
3 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 20

10 September 2025 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8230980
25 July 2024 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7966486
12 July 2023 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7733971
28 November 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7600783
13 September 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7557949
8 July 2022 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7500946
25 April 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7437911
16 August 2021 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7288149
23 July 2021 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7265183
29 July 2020 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7018977
19 September 2019 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6816095
6 June 2019 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6705971
19 July 2018 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6484660
25 June 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6455337
18 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6290754
7 August 2017 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6248081
2 August 2017 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6233489
27 July 2017 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6226314
31 March 2017 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6116618
23 June 2016 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5923351

Deficiency record · 8

07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 12 July 2023 Resolved
Monthly fire extinguisher inspections are not being completed. Develop method to complete and track these inspections.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 12 July 2023
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 July 2021 Resolved
Replace batteries. Could not start vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 July 2021
Resolved 16 August 2021
Resolution: Batteries were exchanged
01 - Certificates & Documentation › 013 - Documents › Conformance Test Report
Issued 6 June 2019 Resolved
Missing annual DAPI MIS report. 46 CFR 16.500(c)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2019
Resolved 7 August 2020
Resolution: Annual inspection completed in 2020 has no issues with DAPI MIS report.
08 - Alarms › N/A - No Subsystem › Emergency signal
Issued 19 July 2018 Resolved
Bilge alarm not working. Must fix prior to carry passengers. 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 July 2018
Resolved 19 September 2019
Documentation › Markings/Placards › Vessel Number (state)
Issued 27 July 2017 Resolved
Provide state registration and numbers (IL) per 33 CFR 173.15
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 March 2018
Resolved 26 June 2018
Resolution: Received IL State Registration IL8799KW
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 27 July 2017 Resolved
Provide current list of employees in random pool per 46 CFR 16.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2017
Resolved 7 August 2017
Resolution: Completed DAPI Audit with [name withheld] of Westrec Marine - [phone withheld]
Personnel › Training › Familiarization Training
Issued 27 July 2017 Resolved
Develop program and provide proof of training of all masters in writting to cover all emergency duties and make available for drills per 46 CFR 185.420, 185.520 and 185.524
Condition: Invalid
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 2 August 2017
Resolution: Verified training program and documents for drills and exercises
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 27 July 2017 Resolved
The following masters must prove ability to conduct drill per the company's emergency proceedures prior to serving as master [name withheld], [name withheld] and [name withheld] per 46 CFR 176.840.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2017
Resolution: Conducted Drills, MOB and Fire Drills to the companies emergency procedures

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.