Records from 2016 to 2025. Most recent: inspection, 2 September 2025.
Inspection history · 17
2 September 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8210890
18 November 2024
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8006562
10 September 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7987329
5 September 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7768183
1 November 2022
Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7558146
8 September 2022
COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7552888
28 April 2022
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7439673
21 September 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7317626
12 November 2020
Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7094388
14 October 2020
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7077492
21 September 2020
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7062634
19 September 2019
Administrative Inspection · DAPI Audit · Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6815893
20 November 2018
Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6575164
15 October 2018
Deficiency Check · Annual Inspection · Internal Structural Exam · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6553636
20 September 2017
DAPI Audit · Deficiency Check · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6269862
4 November 2016
Internal Structural Exam · Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6034998
19 August 2016
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5981329
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. Several dead-end wires were found in the stowage locker, located forward of the operating station. Remove or cap dead-end wires to the satisfaction of the attending marine inspector. - 46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 5 September 2025
Resolution: All dead-end wires have been removed. Photos have been uploaded under "documents" of this section.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 September 2023
Resolved
All vessels must have navigation lights that are in compliance with the applicable section of the International and Inland Navigation Rules. Vessels stern light was inoperable, replace with working light.
46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2023
Resolution: Stern light was operable.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 September 2023
Resolved
The master and the crew of a vessel will be familiar with the content of and have mounted at the operating station emergency instructions containing the actions to be taken in the event of fire, heavy weather or man overboard conditions. Vessel did not have heavy weather emergency instructions posted. Post heavy weather emergency instructions.
46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2023
Resolution: Heavy weather emergency instruction placard was posted.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 September 2023
Resolved
A visual and audible alarm must be provided a the operating station to indicate a high water level in the following normally unmanned spaces, i.e. machinery space bilge. Engine room bilge alarm did not light up at the operating station. Replace lights at operating station.
46 CFR 182.530 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2023
Resolution: Engine room bilge alarm lgiht was visible at the operating station.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 September 2023
Resolved
Portable fire extinguishers installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Vessels bungee chord was worn securing 02 extinguishers in place. Replace with stronger bungee chords.
46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2023
Resolution: Bungee chords were replaced with new chords.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 November 2022
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Fractured welds in the following locations:
1. In midship compartment, 9 fractured welds at the base of lateral frames.
2. In forward compartment, 2 fractured welds at the base of lateral frames.
3. At the base of the port side capstan box, 1 fractured weld. Scarf and reweld all weld fractures.
46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 8 November 2022
Resolution: All fractured welds were re-welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2022
Resolved
Water lubricated rubber bearings must be rebushed when any water groove is half the original depth. Port and stbd cutlass bearings are worn. Replace.
46 CFR 61.20-23
Action required: 705 - Other - as specified
Resolved 8 November 2022
Resolution: Cutlass bearings replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 November 2022
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Aft swim ladder bracket fractured. Replace and reweld bracket.
46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 8 November 2022
Resolution: Bracket renewed and re-welded.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 November 2022
Resolved
When required by the marine inspector, a portion of the inspection must be conducted while the vessel is underway. Conduct sea trial prior to credit drydock.
46 CFR 176.802 (c)
Action required: 705 - Other - as specified
Resolved 8 November 2022
Resolution: Sea trial completed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 8 September 2022
Resolved
A Certificate of Documentation is required for the operation of a vessel in certain trades, serves as evidence of vessel nationality, and permits a vessel to be subject to preferred mortgages. A valid Certificate of Documentation was not present. Provide a valid Certificate of Documentation.
46 CFR 67.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 14 November 2022
Resolution: Provided evidence that COD is now on board the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 September 2022
Resolved
A vessel must have one or more ring life buoys as follows: A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Life ring buoy color is fading. Replace life ring buoy.
46 CFR 180.70(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 20 September 2022
Resolution: Provided new life ring buoy.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 September 2022
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Identified 8 fractured welds in midship compartment. Three of the welds were on the forward three frames and five on the port frames. Fractured welds were marked and are located where the chine meets the frames.
Action required: 705 - Other - as specified
Resolved 8 September 2022
Resolution: Special note added to ensure welds are repaired prior to completion of next credit dry dock.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 September 2020
Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions. Ampule-breaking mechanism does not match the manufacturer's instructions. Either provide evidence from manufacturer that the current configuration is satisfactory, or configure according to manufacturer's instructions.
46CFR181.420(a)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2020
Resolution: Vessel installed new FireBoy IAW manufacturer's instructions. Witnessed satisfactory operational test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 September 2019
Resolved
The employer shall provide an Employee Assistance Program (EAP) and training for all crewmembers. Vessel has no documentation of supervisor or crewmember training on EAP.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2019
Resolved 1 October 2019
Resolution: Received documentation that the supervisory training was conducted and documented.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 October 2018
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a); Vessel does not have required portable hand pump. Provide portable hand pump for vessel
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 October 2018
Resolution: Provided portable hand pump.
Electrical › Electric Supply System (service) › Cable
Issued 20 September 2017
Resolved
Install metal supports on electrical cabling in engine room spaced not more than 24 inches apart.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 6 October 2017
Resolution: Provided photos of metal supports.
Engineering › Steam System (main) › Piping
Issued 20 September 2017
Resolved
Replace fitting that is corroded on steering gear system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 6 October 2017
Resolution: Provided photo of fitting.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 4 November 2016
Resolved
Cutlas bearing starboard side worn; replace IAW 46 CFR 176.610(a)
Due 4 December 2016
Resolved 12 January 2017
Resolution: NEW CUTLAS BEARINGS INSTALLED.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 November 2016
Resolved
port side raw water intake hose damaged; replace IAW 46 CFR 182.700,710,720
Due 4 December 2016
Resolved 15 November 2016
Resolution: INTAKE HOSE REPLACED.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 4 November 2016
Resolved
BII portable fire extinguisher bottle has excessive corrosion; replace IAW 46 CFR 181.500(a)
Due 18 November 2016
Resolved 15 November 2016
Resolution: NEW PORTABLE FIRE EXTINGUISHER PURCHASED AND INSTALLED.
Lifesaving › Lifebuoys › Serviceable
Issued 4 November 2016
Resolved
Ring buoy unserviceable; replace IAW 46 CFR 180.70
Due 18 November 2016
Resolved 15 November 2016
Resolution: NEW RING BUOY PURCHASED AND INSTALLED.
Construction/Loadline › Penetrations › Gasket
Issued 4 November 2016
Resolved
Stuffing tube in forward compartment deteriorated; re-pack IAW 46 CFR 179.320(c)
Due 18 November 2016
Resolved 15 November 2016
Resolution: STUFFING TUBE IN FORWARD COMPARTMENT RE-PACKED.