KAIOU

KAIOU is a 2012 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in September 2025, along with 22 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 2 September 2025.

Built
2012
Last inspected
2 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDG5075
1170740
Flag
UNITED STATES
Maury page id
psix-1170740

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspections, by type

Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Registered dimensions (L × B × D)35.0 ft × 13.6 ft × 7.8 ft
Registered tonnagegross 24 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNORTHWIND MARINE INC · SEATTLE, WA, UNITED STATES · built 2012
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portHALEIWA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 14 November 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it24 - Simplified, Gross Ton
19 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

2 September 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8210890
18 November 2024 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8006562
10 September 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7987329
5 September 2023 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7768183
1 November 2022 Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7558146
8 September 2022 COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7552888
28 April 2022 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7439673
21 September 2021 Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7317626
12 November 2020 Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7094388
14 October 2020 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7077492
21 September 2020 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7062634
19 September 2019 Administrative Inspection · DAPI Audit · Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6815893
20 November 2018 Drydock Exam · Administrative Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6575164
15 October 2018 Deficiency Check · Annual Inspection · Internal Structural Exam · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6553636
20 September 2017 DAPI Audit · Deficiency Check · COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6269862
4 November 2016 Internal Structural Exam · Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6034998
19 August 2016 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5981329

Deficiency record · 22

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 September 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to: protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment and electrical shock. Several dead-end wires were found in the stowage locker, located forward of the operating station. Remove or cap dead-end wires to the satisfaction of the attending marine inspector. - 46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 September 2025
Resolved 5 September 2025
Resolution: All dead-end wires have been removed. Photos have been uploaded under "documents" of this section.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 September 2023 Resolved
All vessels must have navigation lights that are in compliance with the applicable section of the International and Inland Navigation Rules. Vessels stern light was inoperable, replace with working light. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2023
Resolution: Stern light was operable.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 September 2023 Resolved
The master and the crew of a vessel will be familiar with the content of and have mounted at the operating station emergency instructions containing the actions to be taken in the event of fire, heavy weather or man overboard conditions. Vessel did not have heavy weather emergency instructions posted. Post heavy weather emergency instructions. 46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2023
Resolution: Heavy weather emergency instruction placard was posted.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 5 September 2023 Resolved
A visual and audible alarm must be provided a the operating station to indicate a high water level in the following normally unmanned spaces, i.e. machinery space bilge. Engine room bilge alarm did not light up at the operating station. Replace lights at operating station. 46 CFR 182.530 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2023
Resolution: Engine room bilge alarm lgiht was visible at the operating station.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 September 2023 Resolved
Portable fire extinguishers installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Vessels bungee chord was worn securing 02 extinguishers in place. Replace with stronger bungee chords. 46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 September 2023
Resolution: Bungee chords were replaced with new chords.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 November 2022 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Fractured welds in the following locations: 1. In midship compartment, 9 fractured welds at the base of lateral frames. 2. In forward compartment, 2 fractured welds at the base of lateral frames. 3. At the base of the port side capstan box, 1 fractured weld. Scarf and reweld all weld fractures. 46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 8 November 2022
Resolution: All fractured welds were re-welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2022 Resolved
Water lubricated rubber bearings must be rebushed when any water groove is half the original depth. Port and stbd cutlass bearings are worn. Replace. 46 CFR 61.20-23
Action required: 705 - Other - as specified
Resolved 8 November 2022
Resolution: Cutlass bearings replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 1 November 2022 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Aft swim ladder bracket fractured. Replace and reweld bracket. 46 CFR 177.300
Action required: 705 - Other - as specified
Resolved 8 November 2022
Resolution: Bracket renewed and re-welded.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 November 2022 Resolved
When required by the marine inspector, a portion of the inspection must be conducted while the vessel is underway. Conduct sea trial prior to credit drydock. 46 CFR 176.802 (c)
Action required: 705 - Other - as specified
Resolved 8 November 2022
Resolution: Sea trial completed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 8 September 2022 Resolved
A Certificate of Documentation is required for the operation of a vessel in certain trades, serves as evidence of vessel nationality, and permits a vessel to be subject to preferred mortgages. A valid Certificate of Documentation was not present. Provide a valid Certificate of Documentation. 46 CFR 67.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 14 November 2022
Resolution: Provided evidence that COD is now on board the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 September 2022 Resolved
A vessel must have one or more ring life buoys as follows: A vessel of more than 7.9 meters (26 feet) in length, but not more than 19.8 meters (65 feet), must carry a minimum of one life buoy of not less than 610 millimeters (24 inches) in diameter. Life ring buoy color is fading. Replace life ring buoy. 46 CFR 180.70(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 September 2022
Resolved 20 September 2022
Resolution: Provided new life ring buoy.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 September 2022 Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Identified 8 fractured welds in midship compartment. Three of the welds were on the forward three frames and five on the port frames. Fractured welds were marked and are located where the chine meets the frames.
Action required: 705 - Other - as specified
Resolved 8 September 2022
Resolution: Special note added to ensure welds are repaired prior to completion of next credit dry dock.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 21 September 2020 Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer's instructions. Ampule-breaking mechanism does not match the manufacturer's instructions. Either provide evidence from manufacturer that the current configuration is satisfactory, or configure according to manufacturer's instructions. 46CFR181.420(a)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 October 2020
Resolution: Vessel installed new FireBoy IAW manufacturer's instructions. Witnessed satisfactory operational test.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 September 2019 Resolved
The employer shall provide an Employee Assistance Program (EAP) and training for all crewmembers. Vessel has no documentation of supervisor or crewmember training on EAP.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2019
Resolved 1 October 2019
Resolution: Received documentation that the supervisory training was conducted and documented.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 October 2018 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a); Vessel does not have required portable hand pump. Provide portable hand pump for vessel
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 October 2018
Resolution: Provided portable hand pump.
Electrical › Electric Supply System (service) › Cable
Issued 20 September 2017 Resolved
Install metal supports on electrical cabling in engine room spaced not more than 24 inches apart.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 6 October 2017
Resolution: Provided photos of metal supports.
Engineering › Steam System (main) › Piping
Issued 20 September 2017 Resolved
Replace fitting that is corroded on steering gear system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2017
Resolved 6 October 2017
Resolution: Provided photo of fitting.
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 4 November 2016 Resolved
Cutlas bearing starboard side worn; replace IAW 46 CFR 176.610(a)
Due 4 December 2016
Resolved 12 January 2017
Resolution: NEW CUTLAS BEARINGS INSTALLED.
Engineering › Sea-water System (primary cooling) › Piping
Issued 4 November 2016 Resolved
port side raw water intake hose damaged; replace IAW 46 CFR 182.700,710,720
Due 4 December 2016
Resolved 15 November 2016
Resolution: INTAKE HOSE REPLACED.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 4 November 2016 Resolved
BII portable fire extinguisher bottle has excessive corrosion; replace IAW 46 CFR 181.500(a)
Due 18 November 2016
Resolved 15 November 2016
Resolution: NEW PORTABLE FIRE EXTINGUISHER PURCHASED AND INSTALLED.
Lifesaving › Lifebuoys › Serviceable
Issued 4 November 2016 Resolved
Ring buoy unserviceable; replace IAW 46 CFR 180.70
Due 18 November 2016
Resolved 15 November 2016
Resolution: NEW RING BUOY PURCHASED AND INSTALLED.
Construction/Loadline › Penetrations › Gasket
Issued 4 November 2016 Resolved
Stuffing tube in forward compartment deteriorated; re-pack IAW 46 CFR 179.320(c)
Due 18 November 2016
Resolved 15 November 2016
Resolution: STUFFING TUBE IN FORWARD COMPARTMENT RE-PACKED.