O7 VEGA S

O7 VEGA S is a 2011 public freight. The Coast Guard has recorded 8 inspections since 2017, most recently in August 2024, along with 8 deficiencies and 1 operational control.

Records from 2017 to 2024. Most recent: inspection, 28 August 2024.

Built
2011
Last inspected
28 August 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9484247
1170756
Flag
ANTIGUA AND BARBUDA
Maury page id
psix-1170756

Inspections, by type

…with no type recorded2
Years with a record 4 calendar years (2017–2024)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it6351 - Convention (Subpart B), Gross Ton
3617 - Convention (Subpart B), Net Ton
9822 - Dead Weight, Metric Ton
12866 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 8

28 August 2024 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7990906
25 August 2024 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7988670
22 March 2022 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7416314
29 October 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7342081
19 June 2021 PSC B
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 7228955
16 September 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6267896
1 August 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6221457
27 July 2017 Ballast Water Examination · ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6222001

Deficiency record · 8

Documentation › Logs/Records › Oil Record Book
Issued 2 August 2017 Resolved
Each operation of the oily water separator shall be recorded in the oil record book. The VSL is equipped with a MEPC 107(49) Oil Content Meter. The records in the ORB do not match what is shown on the OCM. As explained to PSC by ships crew the OCM must be programmed prior to every use. Ships crew is not doing this.
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 16 September 2017
Resolution: SEC HOU-GAL PSC received a class report from BV satisfying the requirement.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 August 2017 Resolved
Oil filtering equipment shall be provided with alarm arrangements as recommended by the organization. VSL is fitted with a MEPC 107(49) Oil Content Meter and is unable to produce the manual. Due to this they are unable to prove proper test procedures.
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 16 September 2017
Resolution: SEC HOU-GAL PSC received a class report from BV satisfying the requirement.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Pump
Issued 2 August 2017 Resolved
After any survey no change shall be made in any items covered by the survey. PSCO identified a suction line from the sludge pump that is not on ships approved drawings.
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 3 August 2017
Resolution: Valve was tack welded to piping and blank flange welded on other side of valve. Class approved.
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 2 August 2017 Resolved
After any survey no change shall be made in any items covered by the survey. PSCO identified that the sewage tank man cover was removed with several drain lines running in to it. Based on discussion with crew this is a permanent arrangement.
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 3 August 2017
Resolution: Cover was properly secured to sewage tank.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 2 August 2017 Resolved
The machinery shall be of design and construction adequate for the service intended. The #2 generator has an epoxy patch on the fresh water thermostat housing. Item was identified on [name withheld] relief dated 24JUN17. No repair parts have been ordered.
Action required: 705 - Other - as specified
Due 1 October 2017
Resolved 31 January 2018
Resolution: Received class report showing def rectification.
Lifesaving › Inflatable Liferafts › Painter
Issued 2 August 2017 Resolved
Before the ship leaves port and at all times during the voyage all lifesaving appliances shall be in working order and ready for immediate use. The port inflatable liferaft painter was incorrectly connected rendering the liferaft inoperable in a emergency.
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 2 August 2017
Resolution: Corrected while onboard.
Electrical › Electrical Distribution System (service) › Overcurrent Device
Issued 2 August 2017 Resolved
Electrical installations shall ensure the safety of the crew and ship from electrical hazards. unapproved electrical installations were identified in the BOSN stores.
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 2 August 2017
Resolution: Corrected prior to completion of PSC exam.
Construction/Loadline › Markings › Load Line Mark
Issued 2 August 2017 Resolved
Deck line shall be marked amidships on each side and painted in white or yellow. Deck line was painted the same color as hull.
Action required: 705 - Other - as specified
Due 2 August 2017
Resolved 2 August 2017
Resolution: Corrected prior to completion of exam.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.