Records in 2018. Most recent: inspection, 6 April 2018.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 4 April 2018
Resolved
Found each werable PFD and ring buoys not marked with vessel name or number, mark each PFD with vessel name or number.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 April 2018
Resolution: Marked
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 4 April 2018
Resolved
Found several type wearable PFD’s with inoperable PFD lights, provide each wearable PFD with an operable CG approved PFD light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 April 2018
Resolution: CG approved PFD lights provided
Lifesaving › Lifejacket/PFD (Type IV) › Storage
Issued 4 April 2018
Resolved
Found ring buoys tied to rails and not immediately available for deployment. Ensure each ring buoy is immediately available for deployment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 April 2018
Resolution: Tie downs removed
Communications › Radio Communications › EPIRB
Issued 4 April 2018
Resolved
Found CAT I EPIRB battery expired back in 2009 and not capable for use. Provide CAT I EPIRB with a non-expired battery.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2018
Resolution: New EPIRB provided on board.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 4 April 2018
Resolved
Found navigational port and starboard running lights installed incorrectly and not visible from headon. Install light correctly with 112.5 degree of visibility.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 April 2018
Resolution: Lights repositioned for 112.5 degree visibility.
Lifesaving › Inflatable Liferafts › Capacity
Issued 4 April 2018
Resolved
Found vessel life raft incapable of accomodating crew capacity of 17. Provide liferaft with capacity of accomodating entire crew.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2018
Resolution: Master removed additional crewmembers to accomodate current life raft capacity.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 April 2018
No resolution recorded
Found main engine, port and starboard generators and multiple moving machinery in the engine room without installed machinery guards. Provide and install machinery guards.
Action required: 15 - Rectify deficiencies by next port