Records from 2012 to 2026. Most recent: inspection, 23 January 2026.
Inspection history · 22
23 January 2026
MTSA Verification · Periodic Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8299997
27 May 2025
Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8162058
18 November 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8035346
25 October 2023
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7814136
11 July 2022
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7503292
23 May 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7452778
22 December 2021
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7373042
6 October 2021
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7327495
6 November 2020
Internal Structural Exam · Periodic Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7092310
9 October 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6830369
15 August 2018
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6511474
12 July 2017
Deficiency Check · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6204410
5 May 2017
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6139418
19 October 2016
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6025737
1 September 2015
Internal Structural Exam · Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5232347
7 July 2014
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4916063
8 July 2013
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4647665
31 August 2012
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4441453
8 August 2012
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4404925
6 August 2012
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4402771
23 July 2012
Deficiency Check · MTSA Verification · In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4384593
2 April 2012
Initial Certification · MARPOL Annex I Examination · Initial Construction-Excluding Oversight · Deadweight Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4277204
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 23 January 2026
Resolved
A vessel over 5 net tons is required to have on board
and available at all times a valid Certificate of
Documentation (COD). The vessels COD had
expired. Provide a copy of a valid COD to the
attending marine inspector as soon as possible.
Extended to 01 May as DHS continues to be shutdown.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 February 2026
Resolved 5 May 2026
Resolution: Received a copy of the valid COD.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2024
Resolved
All lifesaving appliances and arrangements on tank vessels must be in accordance with subchapter W (Lifesaving Appliances and Arrangements) of this chapter. Each vessel must carry lifebuoys approved under approval series 160.150. The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. Grab line of port and STBD lifebuoys is deteriorated and no longer serviceable. Replace to satisfaction of attending USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2024
Resolved 18 December 2024
Resolution: Operator replaced liferings
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 November 2024
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Master did not have certificate of documentation onboard.
Action required: 10 - Deficiency Rectified
Resolved 18 November 2024
Resolution: Master was able to provide original before the end of the inspection
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 October 2019
Resolved
All installations shall be of marine type engines suitable for the intended service. The generator temperature gauge does not work.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 14 November 2019
Resolution: Temperature gauge was replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2019
Resolved
By March 15 of the year following the collection of the data in paragraph (a) of this section, marine employers must submit the data on the form titled U.S. Department of Transportation Drug and Alcohol Testing MIS Data Collection Form by mail to Commandant (CG-INV). Previous year's MIS reports have not been made and submitted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 23 October 2019
Resolution: MIS report submitted to CG-INV
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2019
Resolved
If a stability letter is issued under §170.120 of this chapter, it must be posted under glass or other suitable transparent material in the pilothouse of the vessel. Stability letter not present at time of inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 October 2019
Resolved 23 October 2019
Resolution: Operator provided documentation showing that stability letter is not required (issued by MSC)
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 August 2018
Resolved
Cargo pump pressure gage shall be tested at least once a year. Provide documentation that test has been conducted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 7 September 2018
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 August 2018
Resolved
Cargo relief valves shall be tested once a year. Provide proof of annual cargo relief valve test.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 7 September 2018
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 August 2018
Resolved
For oil products, the words "OIL SERVICE", must be marked on each transfer hose. Label each transfer hose with "OIL SERVICE".
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 15 August 2018
Resolution: OIL SERVICE marked on transfer hose
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 August 2018
Resolved
Each generator must have an ammeter with a selector switch. Demonstrate operational ammeter on generator.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 13 September 2018
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 15 August 2018
Resolved
All cargo tank hatches must be clearly marked in not less than three inches "DANGER-KEEP OUT". Label all cargo tank hatches.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 August 2018
Resolved 13 September 2018
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 August 2018
Resolved
Transfer relief valve must open at or below the pressure at which it is set to open. Must provide documentation of successful bench test or demonstrate cargo pump relief valve open within the parameters it is set to.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 13 September 2018
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 August 2018
Resolved
Pressure gauge must show pressure within 10 percent of the actual pressure. Must provide documentation of successful bench test or demonstrate proper operation of cargo pump pressure gauge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2018
Resolved 13 September 2018
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 12 July 2017
Resolved
Mark both transfer hose with MAWP
Action required: 705 - Other - as specified
Due 26 July 2017
Resolved 23 August 2017
Resolution: Hoses were marked with oil service and MAWP.
Electrical › Electric Generation Source (service) › Generator
Issued 12 July 2017
Resolved
Repair/replace amp meter on generator.
Action required: 705 - Other - as specified
Due 12 July 2017
Resolved 23 August 2017
Resolution: AMP meter was functioning.
Electrical › Electric Supply System (service) › Cable
Issued 19 October 2016
Resolved
Prior to operating block heaters for generator engine submit plan to eliminate the need for entension cord to power. Plans should include list of componants including block heaters and a one line diagram if new wire / cable are being used.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 3 November 2016
Resolution: Block heater only used overnight when no fueling operations are happening. Therefore, allowed use of one hospital-grade extension cord for this application.
Electrical › Electric Supply System (service) › Battery Charger
Issued 19 October 2016
Resolved
Renew broken voltage gauge for generator prime mover battery charger.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 3 November 2016
Resolution: Received copy of receipt for new voltage gauge.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 October 2016
Resolved
Ring lifebuoy found fitted with a non-approved battery. Replace with a battery approved for use in that unit.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 10 November 2016
Resolution: received satisfactory photograchic eveidence of proper battery installation.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 1 September 2015
Resolved
1. Provide proof of testing of all cargo hoses, piping, gauges, and relief valves by 4SEP15.
Action required: 705 - Other - as specified
Due 4 September 2015
Resolved 15 September 2015
Resolution: all tested SAT
Construction/Loadline › Structures › Scuttle
Issued 1 September 2015
Resolved
Prove watertight integrity and proper operation of all wing and rake void hatch covers by 15SEP15.
Action required: 705 - Other - as specified
Due 15 September 2015
Resolved 15 September 2015
Resolution: all water tight and tested SAT.
Construction/Loadline › Hull › Bracket
Issued 1 September 2015
Resolved
Install all deck railing chains by 15SEP15.
Action required: 705 - Other - as specified
Due 15 September 2015
Resolved 15 September 2015
Resolution: All chains installed.
Electrical › Electric Generation Source (service) › Generator
Issued 1 September 2015
Resolved
Prove proper operation of onboard cargo electric generator by 15SEP15.
Action required: 705 - Other - as specified
Due 15 September 2015
Resolved 15 September 2015
Resolution: Gen Set repaired, ground detected in starter, test ran SAT.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 1 September 2015
Resolved
Correct ground in "A" and "B" phase by 04SEP15.
Action required: 705 - Other - as specified
Due 4 September 2015
Resolved 15 September 2015
Resolution: No ground was detected, 2 ground detection bulbs were burnt out and replaced.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 1 September 2015
Resolved
Prove enrollment in drug and alcohol program by 15SEP15.
Action required: 705 - Other - as specified
Due 15 September 2015
Resolved 15 September 2015
Resolution: All DAPI paperwork onboard and up to date.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 7 July 2014
Resolved
Issued 1 def to prove testing of all hoses and piping; label PSI and test date.
Action required: 705 - Other - as specified
Due 11 July 2014
Resolved 7 July 2014
Resolution: Def cleared later that date when POC e-mailed me a copy of the testing certificate.
Stability › Incline Test › General
Issued 23 July 2012
Resolved
issued a 835 for the barge to not operate outside of Boston harbor MA, remain inside a line drawn from Deer Island to Point Allerton till stability calculations can be redone.
Action required: 705 - Other - as specified
Resolved 14 August 2012
Resolution: Cleared 835, current route restricts them to repositioning trips only outside Boston Harbor.
Personnel › Manning/Qualifications › Person in Charge (PIC) of Transfer
Issued 2 April 2012
Resolved
Provide manning to the satisfaction of cognizant OCMI
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2012
Resolved 23 July 2012
Resolution: Issued temp COI new to zone reflecting manning IAW OCMI.
Stability › Water on Deck › General
Issued 2 April 2012
Resolved
Provide retention devices for void covers
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 23 July 2012
Resolution: retention devices installed on void covers.
Lifesaving › Lifebuoys › Quantity
Issued 2 April 2012
Resolved
Provide one additional ring buoy per 46 CFR 199.640(i)(2)
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 23 July 2012
Resolution: (02) ring bouys onboard, cleared 835.
Documentation › Markings/Placards › Vessel Number (state)
Issued 2 April 2012
Resolved
Provide name and hailing port on stern per 46 CFR 67.123
Action required: 705 - Other - as specified
Due 13 July 2012
Resolved 23 July 2012
Resolution: name and hailing port on stern of vessel, cleared 835.
Electrical › Lighting (service) › Lighting Fixture
Issued 2 April 2012
Resolved
Provide/install plugs on two brass electrical deck light fixtures on fwd and aft of house.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2012
Resolved 23 July 2012
Resolution: plugs installed on lights, cleared 835.