← All vessels
HARBOR FUEL 1
Tank Barge · Barge class · Built 2010s · USCG Northeast District (CGD-NE) · Other hulls named HARBOR FUEL 1
HARBOR FUEL 1 is a 2012 tank barge. The Coast Guard has recorded 22 inspections since 2012, most recently in January 2026, along with 31 deficiencies and 3 casualty investigations between 2012 and 2021.
Records from 2012 to 2026. Most recent: inspection, 23 January 2026.
- Built
- 2012
- Last inspected
- 23 January 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 31 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2012–2021
Identity
1238996
1170797
Flag
UNITED STATES
—
Maury page id
psix-1170797
Inspections, by type
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)50.0 ft × 18.5 ft × 6.7 ft
Registered tonnagegross 52 / net 52
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSENESCO MARINE · NORTH KINGSTOWN, RI, UNITED STATES · built 2012
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 May 2026 · expires 31 May 2027
Service, as the file records itTank Barge
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it52 - Simplified, Gross Ton
52 - Simplified, Net Ton
52 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
23 January 2026
MTSA Verification · Periodic Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8299997
27 May 2025
Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8162058
18 November 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8035346
25 October 2023
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7814136
11 July 2022
COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7503292
23 May 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7452778
22 December 2021
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7373042
6 October 2021
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7327495
6 November 2020
Internal Structural Exam · Periodic Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7092310
9 October 2019
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6830369
15 August 2018
MTSA Verification · Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6511474
12 July 2017
Deficiency Check · MTSA Verification · COI Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6204410
5 May 2017
Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6139418
19 October 2016
Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6025737
1 September 2015
Deficiency Check · Internal Structural Exam · Annual Inspection · MTSA Verification
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5232347
7 July 2014
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4916063
8 July 2013
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4647665
31 August 2012
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4441453
8 August 2012
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4404925
6 August 2012
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4402771
23 July 2012
In-Service Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4384593
2 April 2012
Initial Certification · MARPOL Annex I Examination · Initial Construction-Excluding Oversight · Deadweight Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4277204
Deficiency record · 31
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 23 January 2026
Resolved
A vessel over 5 net tons is required to have on board
and available at all times a valid Certificate of
Documentation (COD). The vessels COD had
expired. Provide a copy of a valid COD to the
attending marine inspector as soon as possible.
Extended to 01 May as DHS continues to be shutdown.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2024
Resolved
All lifesaving appliances and arrangements on tank vessels must be in accordance with subchapter W (Lifesaving Appliances and Arrangements) of this chapter. Each vessel must carry lifebuoys approved under approval series 160.150. The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. Grab line of port and STBD lifebuoys is deteriorated and no longer serviceable. Replace to satisfaction of attending USCG Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 November 2024
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Master did not have certificate of documentation onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 October 2019
Resolved
All installations shall be of marine type engines suitable for the intended service. The generator temperature gauge does not work.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2019
Resolved
By March 15 of the year following the collection of the data in paragraph (a) of this section, marine employers must submit the data on the form titled U.S. Department of Transportation Drug and Alcohol Testing MIS Data Collection Form by mail to Commandant (CG-INV). Previous year's MIS reports have not been made and submitted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 October 2019
Resolved
If a stability letter is issued under §170.120 of this chapter, it must be posted under glass or other suitable transparent material in the pilothouse of the vessel. Stability letter not present at time of inspection.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 August 2018
Resolved
Cargo pump pressure gage shall be tested at least once a year. Provide documentation that test has been conducted.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 August 2018
Resolved
Cargo relief valves shall be tested once a year. Provide proof of annual cargo relief valve test.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 August 2018
Resolved
For oil products, the words "OIL SERVICE", must be marked on each transfer hose. Label each transfer hose with "OIL SERVICE".
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 August 2018
Resolved
Each generator must have an ammeter with a selector switch. Demonstrate operational ammeter on generator.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 15 August 2018
Resolved
All cargo tank hatches must be clearly marked in not less than three inches "DANGER-KEEP OUT". Label all cargo tank hatches.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 August 2018
Resolved
Transfer relief valve must open at or below the pressure at which it is set to open. Must provide documentation of successful bench test or demonstrate cargo pump relief valve open within the parameters it is set to.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 15 August 2018
Resolved
Pressure gauge must show pressure within 10 percent of the actual pressure. Must provide documentation of successful bench test or demonstrate proper operation of cargo pump pressure gauge.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 12 July 2017
Resolved
Mark both transfer hose with MAWP
Electrical › Electric Generation Source (service) › Generator
Issued 12 July 2017
Resolved
Repair/replace amp meter on generator.
Electrical › Electric Supply System (service) › Cable
Issued 19 October 2016
Resolved
Prior to operating block heaters for generator engine submit plan to eliminate the need for entension cord to power. Plans should include list of componants including block heaters and a one line diagram if new wire / cable are being used.
Electrical › Electric Supply System (service) › Battery Charger
Issued 19 October 2016
Resolved
Renew broken voltage gauge for generator prime mover battery charger.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 October 2016
Resolved
Ring lifebuoy found fitted with a non-approved battery. Replace with a battery approved for use in that unit.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 1 September 2015
Resolved
1. Provide proof of testing of all cargo hoses, piping, gauges, and relief valves by 4SEP15.
Construction/Loadline › Structures › Scuttle
Issued 1 September 2015
Resolved
Prove watertight integrity and proper operation of all wing and rake void hatch covers by 15SEP15.
Construction/Loadline › Hull › Bracket
Issued 1 September 2015
Resolved
Install all deck railing chains by 15SEP15.
Electrical › Electric Generation Source (service) › Generator
Issued 1 September 2015
Resolved
Prove proper operation of onboard cargo electric generator by 15SEP15.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 1 September 2015
Resolved
Correct ground in "A" and "B" phase by 04SEP15.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 1 September 2015
Resolved
Prove enrollment in drug and alcohol program by 15SEP15.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 7 July 2014
Resolved
Issued 1 def to prove testing of all hoses and piping; label PSI and test date.
Stability › Incline Test › General
Issued 23 July 2012
Resolved
issued a 835 for the barge to not operate outside of Boston harbor MA, remain inside a line drawn from Deer Island to Point Allerton till stability calculations can be redone.
Personnel › Manning/Qualifications › Person in Charge (PIC) of Transfer
Issued 2 April 2012
Resolved
Provide manning to the satisfaction of cognizant OCMI
Stability › Water on Deck › General
Issued 2 April 2012
Resolved
Provide retention devices for void covers
Lifesaving › Lifebuoys › Quantity
Issued 2 April 2012
Resolved
Provide one additional ring buoy per 46 CFR 199.640(i)(2)
Documentation › Markings/Placards › Vessel Number (state)
Issued 2 April 2012
Resolved
Provide name and hailing port on stern per 46 CFR 67.123
Electrical › Lighting (service) › Lighting Fixture
Issued 2 April 2012
Resolved
Provide/install plugs on two brass electrical deck light fixtures on fwd and aft of house.
Casualty record · 3
6 August 2012Routine · role: Source Vessel for Cargo Transfer · activity 4402771
31 August 2012Routine · role: Source Vessel for Cargo Transfer · activity 4441453
22 December 2021Routine · role: Acknowledged Pollution Source · activity 7373042
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.