Records from 2016 to 2024. Most recent: inspection, 16 August 2024.
Inspection history · 6
16 August 2024
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7982522
20 March 2024
Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7882552
13 March 2024
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7878487
13 February 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6351907
16 June 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5902541
28 January 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5805707
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 March 2024
Resolved
Following installation, the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacturer specifications. The valve remote control system for the BWTS is not operational and giving errors.
33CFR151.2025(a)(1)
40ac
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 August 2024
Resolution: Sector Maryland-NCR received tech report attesting to the repairs of the Ballast Water Treatment System.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 13 February 2018
Resolved
DOORS FITTED IN BOUNDARY BULKHEADS OF MACHINERY SPACES OF CATEGORY A SHALL BE REASONABLY GASTIGHT AND SELF-CLOSING. PSCO FOUND OVER SEVEN MACHINERY SPACE CATEGORY A SELF-CLOSING DOORS THAT WERE NOT SELF-CLOSING. 74 SOLAS (2004) II-2/9.4.2.1 (10C)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2018
Resolved 13 February 2018
Resolution: DEFICIENCY WAS RECTIFIED ON THE SPOT TO THE SATISFACTION OF THE COAST GUARD.
Engineering › Steam System (auxiliary) › Piping
Issued 16 June 2016
Resolved
1499 - other - Suitable arrangements shall be provided to preclude, as far as practicable, the entry of oil or other cantaminates which may adversely affect the boiler. PSCO observed contaminated water in the cascade tank. SOLAS (14) II-1/32.5 16a
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 23 June 2016
Resolution: Recieved, Reviewed, and accepted class report from KRS satisfying the requirements. See narrative for details.
Documentation › Logs/Records › Oil Record Book
Issued 16 June 2016
Resolved
1710 - oil record book - The oil record book part I shall be completed on each occasion, on a tank to tank basis. PSCO observed during the review of the ORB that fuel oil overflow and fuel oil drain tanks transfers were not recorded in ORB, although listed in 3.1 of IOPP. MARPOL Ann I/17 16a
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 23 June 2016
Resolution: Recieved, Reviewed, and accepted class report from KRS satisfying the requirements. See narrative for details.