← All vessels
GULF LOYALTY
GULF LOYALTY is a 2011 tank ship. The Coast Guard has recorded 9 inspections since 2012, most recently in July 2025, along with 4 deficiencies.
Records from 2012 to 2025. Most recent: inspection, 25 July 2025.
- Built
- 2011
- Last inspected
- 25 July 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9441245 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7YD6
1171335
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1171335
Inspections, by type
The 9 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it163066 - Convention (Subpart B), Gross Ton
107929 - Convention (Subpart B), Net Ton
364465 - Displacement, Metric Ton
322889 - Dead Weight, Metric Ton
107929 - Convention (Subpart B), Net Ton
364465 - Displacement, Metric Ton
322889 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
25 July 2025
COC-TVE Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8187154
1 May 2024
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7904718
27 February 2024
PSC B · COC-TVE Renew · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7867527
14 August 2019
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6783240
22 July 2019
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6744648
27 June 2018
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6442111
15 February 2017
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6088785
20 August 2015
Ballast Water Examination · COC-TVE Annual · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5218634
12 May 2012
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4306030
Deficiency record · 4
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 27 February 2024
Resolved
IN TANKERS A SYSTEM FOR MONITORING OF THE CONCENTRATION OF HYDROCARBON GASES SHALL BE FITTED. [name withheld] FROM ALL PUMP ROOM FIXED GAS SAMPLING POINTS. PANEL WAS UNABLE TO DETECT GAS APPLITED TO SAMPLING POINTS. - SOLAS 74 (20) II-2/5.10.1.3
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 February 2024
Resolved
IN TANKERS, ELECTRICAL EQUIPMENT, CABLES, AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. PSCO OBSERVED 19 CRACKED EX LIGHTS IN THE CARGO PUMP ROOM AND DECK LOCKERS. - SOLAS 74 (20) II-1/45.11
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 July 2019
Resolved
0710 - MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. LUBE OIL WAS HEAVILY SOAKED ON PIPING INSULATION AND COLLECTING ON THE STEEL DECK BY THE MAIN ENGINE CREATING POTENTIAL FOR A FIRE HAZARD. SOLAS 2014, CH II-2, REG 4.1.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 July 2019
Resolved
0710 - THE ARRANGEMENT FOR THE STORAGE, DISTRIBUTION ABD UTILIZATION OF OIL USED IN LUBRICATION SYSTEMS SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. THE INSULATION SERVICING THE LUBE OIL PIPING WAS HEAVILY SOAKED IN OIL AND DETERIORATING REQUIRING REPLACEMENT. SOLAS 2014, CH. II-2, REG 2.3
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.