Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it163066 - Convention (Subpart B), Gross Ton 107929 - Convention (Subpart B), Net Ton 364465 - Displacement, Metric Ton 322889 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 7
25 July 2025COC-TVE Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8187154
1 May 2024Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7904718
27 February 2024PSC B · COC-TVE Renew · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7867527
14 August 2019Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6783240
22 July 2019COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6744648
27 June 2018ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6442111
15 February 2017Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6088785
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 27 February 2024Resolved
IN TANKERS A SYSTEM FOR MONITORING OF THE CONCENTRATION OF HYDROCARBON GASES SHALL BE FITTED. [name withheld] FROM ALL PUMP ROOM FIXED GAS SAMPLING POINTS. PANEL WAS UNABLE TO DETECT GAS APPLITED TO SAMPLING POINTS. - SOLAS 74 (20) II-2/5.10.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 February 2024
Resolution: Received satisfactory tech and class report. System is operating as designed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 February 2024Resolved
IN TANKERS, ELECTRICAL EQUIPMENT, CABLES, AND WIRING SHALL NOT BE INSTALLED IN HAZARDOUS LOCATIONS UNLESS IT CONFORMS WITH STANDARDS NOT INFERIOR TO THOSE ACCEPTABLE TO THE ORGANIZATION. PSCO OBSERVED 19 CRACKED EX LIGHTS IN THE CARGO PUMP ROOM AND DECK LOCKERS. - SOLAS 74 (20) II-1/45.11
Action required: 15 - Rectify deficiencies by next port
Resolved 1 May 2024
Resolution: Received satisfactory tech and class report.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 July 2019Resolved
0710 - MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. LUBE OIL WAS HEAVILY SOAKED ON PIPING INSULATION AND COLLECTING ON THE STEEL DECK BY THE MAIN ENGINE CREATING POTENTIAL FOR A FIRE HAZARD. SOLAS 2014, CH II-2, REG 4.1.1
Action required: 10 - Deficiency Rectified
Due 23 July 2019
Resolved 14 August 2019
Resolution: OIL CLEANED UP
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 22 July 2019Resolved
0710 - THE ARRANGEMENT FOR THE STORAGE, DISTRIBUTION ABD UTILIZATION OF OIL USED IN LUBRICATION SYSTEMS SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. THE INSULATION SERVICING THE LUBE OIL PIPING WAS HEAVILY SOAKED IN OIL AND DETERIORATING REQUIRING REPLACEMENT. SOLAS 2014, CH. II-2, REG 2.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 August 2019
Resolved 14 August 2019